Loading...
DOCUMENTS /' ti Harnett � . COUNTY _ FMf E•rn.n<r s..w..bew •t wri.Lrmn.op Application for Plant L Review !\ Application# I- I • �� c_ 1 ) •V Date Received: 'A I )(-1 1 I I Received By: Alb of Project: J- LOy fec-c c vA,,"_),)Ie Physical Address of Project: 13739' lkic--fk 11)VAElt05 Lt l ( 1 , NC cOrl6g6 Plans Submitted By: C k(' Project Phone: ( 1 11J t `( Contact Person/Address: LID ) 73 L/U . Contact Email: (2kL to-; conrc)V )00( Contact Phone: ( pp )-1014- 61)Q l Contractor's Namelinfo: Contractor's Phone: ( )- - • Plans that are submitted will be reviewed as quickly as possible with an average time of review between 7-10 working days. • Status checks may be conducted on plan reviews by visiting the website htto:llhteweb.harnett.orq/Click2GovBPllndex.isp or by calling the Harnett County Central Permitting Office(910-893-7525, Option#2), or the Harnett County Fire Marshal's Office (910-893-7580). • Approved plans must be picked up from the Central Permitting Office and all fees paid before any required inspections can be conducted. Jennifer Brock From: Marshall Parrish <MParrish@lillingtonnc.org> Sent: Monday, April 17, 2017 2:29 PM To: Jennifer Brock Subject: Christopher Block Mr. Block is opening a business and doing a small remodeling job on the interior at 133 A West Cornelius Harnett Blvd. The zoning is good for this the type of use (autoparts and installation). Please put his Fire Marshal Review in process. On another note, he said he wants to do the remodel himself and it's under $10,000. Do you know what statute allows commercial property owners to do their own construction if it's under a certain cost? Thanks! Marshall Parrish, CZO Planner and Public Information Officer Town of Lillington 910-893-0311 This message and any response to this message is being sent on a government e-mail system and may be subject to monitoring and disclosure to third parties,including law enforcement personnel. t Harnett COUNTY lit—A--(FM4 a". .q s...w ew....n Plan Review, Inspection, and Permit Fees Application Number 17-50041160 $200.00 ❑ Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 ❑ Fireworks Public Display $ - $50.00 E Final Inspection $ saw $35.00 +52m per device ❑ Fire Alarm Testing $ - $35.00 +$2.00 per noule ❑ Fixed Fire Suppression $ - $75.00 ❑ Insecticide Fog/Fumigation $ - $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 ❑ Plans up to 5000 sq ft $ - $100.00 O Plans 5001 sq ft to 10,000 sq ft $ loom $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 +2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - ❑ Special Assembly $50.00 (le.amusement buildings,carnivals,fairs) $ - $75.00 Tents/Canopies/Air Supported Structure $ DI $100.00 Tank Installation (charge for each tank) $ $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Total Cost $ 150.00 Code Enforcement Official Rodney Daniels 4/19/2017 Harnuertt *A �FMe •►•> . . Sens cor Fire Marshal Division April 19, 2017 Chris Black 340 Bryant Road Dunn, NC 28334 Re: Icon Offroad Inc. 133-A West Cornelius Blvd. Llllington, NC 27546 Application Number 17-50041160 Mr. Black Thank you for submitting the plans for the Icon Offroad upfit. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. Plan Review Notes • 906.1 Fire Extinguishers o Minimum of (1) 2A10:BC fire extinguisher shall be installed per 75' distance of travel. o All Fire extinguisher shall be properly mounted and tagged by a fire extinguisher company. o 506.1 Knox Box o The building owner has been required to install a Knox box. o Provide entry key to be placed in the complex Knox box. • 1006.1 Means of Egress Illumination o The means of egress, including the exit discharge, shall be illuminated at Harnett v M> g. . � a» _ . >.ma. nrHo Lnett all time the building space is served by the means of egress is occupied. o Means of egress consist of three separate and distinct parts: the exit access,the exit and the exit discharge. o The means of egress illumination shall not be less than 1 foot-candle at the walking surface. Notes: o Fire Final Inspection required. "Please schedule all fire inspections with the Fire Marshal's office' 910-893-0743 Thank you again for submitting the plans for Icon Offroad. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Sincerely, odney Da Is Chief Deputy Fire Marshal