Loading...
IPACHTE# I-4-s-'V/1zi Harnett County Department of Public Health 29463 Imarovement Permit A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: YZ o I 1 y/LS /-) L5 R ISSUED C VMbdrlos.A, Wctrac¢g .enc , SUBDIVISION -r l ? 6C.zr— F•.-, LOT # Z NEW TO' REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: YO/Z r ( Z' x 4 * h) 5 F A Proposed Wastewater System Type: 'LSio /4te .je-�cA S Projected Daily Flow: ii -1 S a GPD Number of bedrooms: Number of Occupants: 8 max Basement ❑Yes &No Pump Required: ❑Yes ❑ No Type of Water Supply: ❑ Community Permit conditions: &flay bg required based on final location and elevations of facilities Public ❑ Well Distance from well feet Permit valid for: years ❑ No expiration Authorized State Agedf:: 77f '�� Date: C2 y / 9 / Z G 14 SEE ATTACHED SITE SKETCH The issuance of this permit by the Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not he affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permiL. Construction Authorization squired for Building Permit) The construction and installation requirements of Rules .1950, .1951, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall he met Systems shall be installed in accordance with the attached system layout ISSUED TO: C,r46 rluaca NonV.4s,Znr PROPERTY LOCATION: (4G1S,1%5 0crud C52 PAiS) SUBDIVISION 1M ( �cayc _ LOT # 3 Facility Type: 'i�a((dZ'x �� Sr �Es? New ❑ Expansion ❑ Repair Basement? ❑ Yes Ego< Basement Fixtures? ❑ Yes ❑ No Type of Wastewater System** Z.S%v !!rte e Eec� S, -.ee . (Initial) Wastewater Flow: y39d GPD (See note below, if applicable ❑) ZSia pltdwF'c n S S./c�n (Repair) Installation Requirements/Conditions Number of trenches 3 Septic Tank Size I Zcso gallons Exact length of each trench t oe5 feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of: `L 7 inches (Trench bottoms shall be level to +/.I/4" in all directions) Pump Requirements: (t. TDM vs. GPM Conditions: Trench Spacing: d% Feet on Center Soil Cover: /10 inches (Maximum soil cover shall not exceed 36" above the trench bottom) inches below pipe Aggregate Depth: Z inches above pipe M inches total WATER LINES (INCLUDING IRRIGATION) MUST BE ]OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. **If applicable• / understand the system Ve specified it different from the type Jpecified on the application. / accept the specifications o/ this permit Dwner/Legal Representative Signature: Date: This Construction Authorization is subject to revocation if the site plan, plat. or the intended use changes. The Construction Authorization shall not he transferred when there is a change in ownership of the site. This Construction Authorization is Authorized State with the Provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH Date: 0 d / 19 / LG t 4• Construction Authorization Expiration Date: HTE# I1-6--yiIZI Permit # Z g vas Harnett County Department of Public Health ISSUED TO: C.uzntorl.,ty-N 140 W-2, n( Authorized State Agent: Site Sketch PROPERTYLOCATON: (Ioltins 2�� 52 t1d13 SUBDIVISION TIS,, OP—:sGrVG LOT # 3 _ Date: 01/ I I cI I Z G t �- P*Tto u "� �rt 'Pao PCs rz Lj 6z' Y LW 5r� 1 I Q -%s5 zrzzvr— t)Mrvi�-- N w Gime TCLA K M" I� ip. ut*(-!d iF err Fco i v; til I Ca. n rnai+t�c nF� A(, { 4c� fu 5..75Ec..+ Department of Environment, Health and Natural Resources Division of Environmental Health On -Site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: t4,�'r-j Address: Lod- 3 T(c 'ZeurC Date Evaluated: 0I[//'9/lam Proposed Facility: W(7— St'S Design Flow (.1949): 9?17 tT Location of Site: 2.at; A5 2 Property Recorded: )v Water Supply:Public❑ Individual ❑ Well Evaluation Method:[4--gger Boring _. ❑ Pit ❑ Cut Type of Wastewater: ewage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: D 4 9! A L ❑ Spring ❑ Other ❑ Mixed P R O F 1 .1940 SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS L E Landscape Position/ Slope% Horizon Depth (In.) ,1941 Structure/ Scture/ Texture .1941 Consistence Mmetalogy .1942 Soil Wetness/ Color .1943.1956 Soil Depth (IN .) Sapro Class .1944 Rear Horiz Profile Class & LTAR L 3% — � S L SfSP4�y PS �' SGL fl S('f�f SY26/Z �7%t` 1f� G•4 R1 SSjp Syr PS G(Z 5L P;� - �7 qY" H c) s L JfS'S�- PS 3-48 Description Inisitaml —System Other Factors (.1946): Available Space (.1945) S r Site Classification ( 1948 ): pn cv,.? , f , ;1 Evaluated By: SystemT e(s) i2i ;L 2i L Z lzet Others Present: Ano&--> L.sr- rtq Ems. Site LTAR (j.