Loading...
FM REVIEW ; Harnett + COUNTY A- fr;) Emergency rw..u.Department inns Aernemeog Plan Review, Inspection, and Permite Fees Application Number . 17-50040725 $100.00 ❑ DRB Major Sub Division Prelim Site Plans $ - $200.00 ❑ Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 ❑ Fireworks Public Display $ - $50.00 0 Final Inspection 5 50.00 $35.00 +$2.00 per device ❑ Fire Alarm Testing $ - $35.00 +$2.00 per nozzle ❑ Fixed Fire Suppression $ - $75.00 ❑ Insecticide Fog/Fumigation $ $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 ❑ Plans up to 5000 sq ft $ - $100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $ $150.00 0 Plans 10,001 sq ft to 25,000 sq ft $ 150.00 $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 +2.00per head ❑ Sprinkler Certification Test $ $50.00 ❑ Standpipe Testing $ $50.00 ❑ Special Assembly lie.amusement buildings,carnivals,fairs) $ - El $75.00 Tents/Canopies/Air Supported Structure $ - El $100.00 Tank Installation (charge for each tank) $ - $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Total Cost $ 200.00 Code Enforcement Official Jeff D. Johnson 4/28/2017 Harnett C O U N T Y � �� Emergency lemon u•wrbwoot ® Mr ww.L.nwn.wy Fire Marshal Division April 28, 2017 Re: Campbell University School of Engineering Burt Street Butes Creek, NC 27506 Application Number 15-50040725 Brett Strickland, Thank you for submitting the plans for the new building. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • Comments o Provide a hazardous materials management plan and inventory of all chemicals stored and used. o Approved flammable & combustible liquids cabinets may be required where exceeding 10 gallons inside the building. o Verify the classification and division wiring method in labs and exhaust fans? (If flammable &combustible liquids are stored or used in labs). • 506.1 Knox Box o A Knox Box is required to be installed on the building. Please see the link below to order Knox box. Paper order form available upon request. o https://www.knoxbox.com/store/Knox-Box-3200-Series.cfm • 503.2.3 Fire Apparatus Access Road Surface. o Fire department access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be surfaced to provide all-weather driving capabilities. • 503.3 Markings. o Where required by the fire code official approved signs or other approved markings that include the words NO PARKING — FIRE LANE shall be provided for fire apparatus access roads to identify such roads or prohibit the obstruction thereof. Harnett COUNTY * ® o.•, Ens.p.ncr s«wu.Dip/entree/it mwwhamen.nq • 505.1 Address Numbers o The physical address shall be installed on the building so that it is visible from the approach side, minimum size of 6 inch. o The numbers shall be of contrasting colors. • 906.1 Fire Extinguishers required. o A minimum 2A10BC classification of fire extinguisher is required on each floor and located so that the maximum travel distance to reach an extinguisher does not exceed 75ft. o Fire Extinguishers shall be located in approved cabinets along corridors. o All fire extinguishers shall be mounted not higher than 5k. above the finished floor and in accordance with NFPA 10. • 1006 Illumination emergency power. o In the event of power supply failure, an emergency electrical system shall automatically illuminate corridors, exit enclosures in buildings required to have two or more exits. Recommend emergency illumination in bathrooms consistent with Accessibility code. • Comments o A final fire inspection is required. o Schedule all fire inspections through the Fire Marshal's Office. (910)893-0743 Thank you again for submitting the plans for the new building. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Sincerely, 1y^"U14�y/,✓' leCICJ . Johnson Deputy Fire Marshal cr.- Harnett COUNTY ® o ` m,.,9,,,n,int"n,n„eT,,,, Plan Review, Inspection, and Permit Fees Application Number 17-50040725 $200.00 ❑ Explosive Material (90 Days) $ - $100.00 fl Explosive Materials (72 Hours) $ - $100.00 0 Fireworks Public Display $ - $50.00 0 Final Inspection $ - $35.00 +$2.00 per device o Fire Alarm Testing $ 35.00 $35.00 +$2.00 per nozzle 0 Fixed Fire Suppression $ - $75.00 0 Insecticide Fog/Fumigation $ - $100.00 0 Pipe Test/UST/AGST $ - $50.00 0 Plans up to 5000 sq ft $ - $100.00 0 Plans 5001 sq ft to 10,000 sq ft $ - $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 fl Plans 25,001 sq ft and over $ - $35.00 +2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - $50.00 ❑ Special Assembly (ie.amusement buildings,carnivals,fairs) $ - $75.00 ❑ Tents/Canopies/Air Supported Structure $ - $100.00 ❑ Tank Installation (charge for each tank) $ - $100.00 0 Tank Removal (charge for each tank) $ - 12 Total Devices/Heads $ 24.00 Total Cost $ 59.00 Code Enforcement Official Rodney Daniels 5/22/2017 ter -N Harnett co..u,",.Try'' ���) twv gory s..:u.Department vn.bansettary May 17, 2017 Re: Campbell University School of Engineering Burt Street Buses Creek, NC 27506 Application Number 17-50040725 Brett Strickland, Thank you for submitting the fire alarm plans. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • Fire Alarm System Plan Review Notes o Provide a record of completion. o Provide a signed monitoring agreement. o Provide a copy of pretest history from the central station. o The Fire marshal's office will complete an acceptance test at completion of project. (100%) o Provide a copy of account history after the acceptance test is completed and approve. o Provide an accurate zone map at the FACP and remote annunciator panel. o All work/installation shall be compliant with the NCSFC and NFPA 72. o Call Fire Marshal's office to schedule the fire alarm acceptance test. (910-893-0743) o The addition of the proposed future walls may requires additional notification devices to be installed at that time. Thank you again for submitting fire alarm plans. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions,please do not hesitate to call this office. Harnett r COUNTY ® ♦+ KURT- LhAe0,m) &menKr service D.W�r 'Y' wwlu.n.n.erp Again, thank you and we look forward to working with you during the construction period! Sincerely, Adze, ,Vatta4 Rodney Daniels Chief Deputy Fire Marshal HCFM Office of the Fire Marshal P.O. Box 370 Lillington, N.C. 27546 (910)493-7580 Permit Certificate Business Name: CAMPBELL UNIVERSITY ENGINEERING SCHOOL Address: BURT ST LILLINGTON, NC 27546 Phone: The following permit has been issued: Permit No. 1750041387 Type: 045 Fire Alarm Permit Issued Date: 05/17/2017 Effective Date: 05/17/2017 Expiration Date: 05/17/2018 This permit certificate has been issued for[ 1 construction/ [ 1 operational purposes located at the above business location.This permit has been issued and will be enforced in accordance with section toy of the N.C. State Fire Prevention Code. Please contact our office for any further questions regarding this permit. Prea c== --S111:) C/7/1) Inspector: Ro4y Keith Daniels Date 05/17/2017 Page 1