FM REVIEW ; Harnett
+ COUNTY
A- fr;) Emergency rw..u.Department
inns Aernemeog
Plan Review, Inspection, and Permite Fees
Application Number . 17-50040725
$100.00 ❑ DRB Major Sub Division Prelim Site Plans $ -
$200.00 ❑ Explosive Material (90 Days) $ -
$100.00 ❑ Explosive Materials (72 Hours) $ -
$100.00 ❑ Fireworks Public Display $ -
$50.00 0 Final Inspection
5 50.00
$35.00 +$2.00 per device ❑ Fire Alarm Testing $ -
$35.00 +$2.00 per nozzle ❑ Fixed Fire Suppression $ -
$75.00 ❑ Insecticide Fog/Fumigation $
$100.00 ❑ Pipe Test/UST/AGST $ -
$50.00 ❑ Plans up to 5000 sq ft $ -
$100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $
$150.00 0 Plans 10,001 sq ft to 25,000 sq ft $ 150.00
$250.00 ❑ Plans 25,001 sq ft and over $ -
$35.00 +2.00per head ❑ Sprinkler Certification Test $
$50.00 ❑ Standpipe Testing $
$50.00 ❑ Special Assembly
lie.amusement buildings,carnivals,fairs) $ -
El
$75.00 Tents/Canopies/Air Supported Structure
$ -
El
$100.00 Tank Installation (charge for each tank)
$ -
$100.00 ❑ Tank Removal (charge for each tank) $ -
Total Devices/Heads $ -
Total Cost $ 200.00
Code Enforcement Official Jeff D. Johnson 4/28/2017
Harnett
C O U N T Y �
�� Emergency lemon u•wrbwoot
®
Mr ww.L.nwn.wy
Fire Marshal Division
April 28, 2017
Re: Campbell University School of Engineering
Burt Street
Butes Creek, NC 27506
Application Number 15-50040725
Brett Strickland,
Thank you for submitting the plans for the new building. The plans have been carefully
reviewed by a qualified code enforcement official to examine for compliance with the
North Carolina Fire Prevention Code and all other fire protection regulatory documents.
There are some items that were found during the plan review process that need to be
addressed before a final inspection of the new facility can be given. These items are
outlined and described below.
• Comments
o Provide a hazardous materials management plan and inventory of all
chemicals stored and used.
o Approved flammable & combustible liquids cabinets may be required
where exceeding 10 gallons inside the building.
o Verify the classification and division wiring method in labs and exhaust
fans? (If flammable &combustible liquids are stored or used in labs).
• 506.1 Knox Box
o A Knox Box is required to be installed on the building. Please see the link
below to order Knox box. Paper order form available upon request.
o https://www.knoxbox.com/store/Knox-Box-3200-Series.cfm
• 503.2.3 Fire Apparatus Access Road Surface.
o Fire department access roads shall be designed and maintained to
support the imposed loads of fire apparatus and shall be surfaced to
provide all-weather driving capabilities.
• 503.3 Markings.
o Where required by the fire code official approved signs or other
approved markings that include the words NO PARKING — FIRE LANE shall
be provided for fire apparatus access roads to identify such roads or
prohibit the obstruction thereof.
Harnett
COUNTY * ® o.•, Ens.p.ncr s«wu.Dip/entree/it
mwwhamen.nq
• 505.1 Address Numbers
o The physical address shall be installed on the building so that it is visible
from the approach side, minimum size of 6 inch.
o The numbers shall be of contrasting colors.
• 906.1 Fire Extinguishers required.
o A minimum 2A10BC classification of fire extinguisher is required on each
floor and located so that the maximum travel distance to reach an
extinguisher does not exceed 75ft.
o Fire Extinguishers shall be located in approved cabinets along corridors.
o All fire extinguishers shall be mounted not higher than 5k. above the
finished floor and in accordance with NFPA 10.
• 1006 Illumination emergency power.
o In the event of power supply failure, an emergency electrical system shall
automatically illuminate corridors, exit enclosures in buildings required to
have two or more exits. Recommend emergency illumination in
bathrooms consistent with Accessibility code.
• Comments
o A final fire inspection is required.
o Schedule all fire inspections through the Fire Marshal's Office.
(910)893-0743
Thank you again for submitting the plans for the new building. Please review the plans
and adhere to any notes and alterations that were made in addition to the original
drawings. These remarks are for the plans that were submitted and its original intent.
These remarks do not apply if the original intent changes or what was submitted on the
above date changes. If you have any questions, please do not hesitate to call this office.
Sincerely,
1y^"U14�y/,✓'
leCICJ
. Johnson
Deputy Fire Marshal
cr.- Harnett
COUNTY ® o ` m,.,9,,,n,int"n,n„eT,,,,
Plan Review, Inspection, and Permit Fees
Application Number 17-50040725
$200.00 ❑ Explosive Material (90 Days) $ -
$100.00 fl Explosive Materials (72 Hours) $ -
$100.00 0 Fireworks Public Display $ -
$50.00 0 Final Inspection $ -
$35.00 +$2.00 per device o Fire Alarm Testing $ 35.00
$35.00 +$2.00 per nozzle 0 Fixed Fire Suppression $ -
$75.00 0 Insecticide Fog/Fumigation $ -
$100.00 0 Pipe Test/UST/AGST $ -
$50.00 0 Plans up to 5000 sq ft $ -
$100.00 0 Plans 5001 sq ft to 10,000 sq ft $ -
$150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ -
$250.00 fl Plans 25,001 sq ft and over $ -
$35.00 +2.00 per head ❑ Sprinkler Certification Test $ -
$50.00 ❑ Standpipe Testing $ -
$50.00 ❑ Special Assembly
(ie.amusement buildings,carnivals,fairs) $ -
$75.00 ❑ Tents/Canopies/Air Supported Structure $ -
$100.00 ❑ Tank Installation (charge for each tank) $ -
$100.00 0 Tank Removal (charge for each tank) $ -
12 Total Devices/Heads $ 24.00
Total Cost $ 59.00
Code Enforcement Official Rodney Daniels 5/22/2017
ter -N Harnett
co..u,",.Try'' ���) twv gory s..:u.Department
vn.bansettary
May 17, 2017
Re: Campbell University School of Engineering
Burt Street
Buses Creek, NC 27506
Application Number 17-50040725
Brett Strickland,
Thank you for submitting the fire alarm plans. The plans have been carefully reviewed by
a qualified code enforcement official to examine for compliance with the North Carolina
Fire Prevention Code and all other fire protection regulatory documents. There are some
items that were found during the plan review process that need to be addressed before a
final inspection of the new facility can be given. These items are outlined and described
below.
• Fire Alarm System Plan Review Notes
o Provide a record of completion.
o Provide a signed monitoring agreement.
o Provide a copy of pretest history from the central station.
o The Fire marshal's office will complete an acceptance test at
completion of project. (100%)
o Provide a copy of account history after the acceptance test is
completed and approve.
o Provide an accurate zone map at the FACP and remote annunciator
panel.
o All work/installation shall be compliant with the NCSFC and NFPA
72.
o Call Fire Marshal's office to schedule the fire alarm acceptance test.
(910-893-0743)
o The addition of the proposed future walls may requires additional
notification devices to be installed at that time.
Thank you again for submitting fire alarm plans. Please review the plans and adhere to
any notes and alterations that were made in addition to the original drawings. These
remarks are for the plans that were submitted and its original intent. These remarks do not
apply if the original intent changes or what was submitted on the above date changes. If
you have any questions,please do not hesitate to call this office.
Harnett
r COUNTY ® ♦+
KURT- LhAe0,m) &menKr service D.W�r
'Y' wwlu.n.n.erp
Again, thank you and we look forward to working with you during the construction
period!
Sincerely,
Adze, ,Vatta4
Rodney Daniels
Chief Deputy Fire Marshal
HCFM
Office of the Fire Marshal
P.O. Box 370
Lillington, N.C. 27546
(910)493-7580
Permit Certificate
Business Name: CAMPBELL UNIVERSITY ENGINEERING SCHOOL
Address: BURT ST
LILLINGTON, NC 27546
Phone:
The following permit has been issued: Permit No. 1750041387
Type: 045 Fire Alarm Permit
Issued Date: 05/17/2017
Effective Date: 05/17/2017
Expiration Date: 05/17/2018
This permit certificate has been issued for[ 1 construction/ [ 1 operational purposes located
at the above business location.This permit has been issued and will be enforced in accordance
with section toy of the N.C. State Fire Prevention Code. Please contact our office for any further
questions regarding this permit.
Prea c== --S111:) C/7/1)
Inspector: Ro4y Keith Daniels Date
05/17/2017 Page 1