IPACHTE# I`1-`a—YU(o3o Harnett County Department of Public Health 29171
Improvement Permit
A building permit cannot be issued with only an Improvement Permit n
��` PROPERTY LOCATION: _22t r
ISSUED TO- CL -*2 f„r}���TOT� _T��� SUBDIVISION Q uW4�t col %7J LOT #
NEW Gd REPAIR ❑��E%PANSION 13 Site Improvements required prior to Construction Authorization Issuance:
Type of Structure:
Proposed Wastewater System Trpe: ZS
Projected Daily Flow: L'1 cG' d GPD
Number of bedrooms: �L" Number Occupants: max
Basement []Yes LAND
Pump Required: ❑Yes ❑ No�M�a' a required based on final location and elevations of facilities
Type of Water Supply: El Community Ia3 Public ❑ Well Distance from well feet Permit valid for. 21 ve years
Permit conditions: ❑ No expiration
Authorized State Date: Z `�/ / 1 SEE ATTACHED SITE SKETCH
The issuance of this permit by IJ alth Department in no way guarantees the issuance ir other permits. The permit holder u responsible for checking with appropriate governing bodies in meeting their requirements. This
site is subject to revocation if t site plan, plat or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site This permit is subject in compliance with the provisions of
the taws and Rules for Sewage Treatment and Disposal and to conditions of this permit.
Construction Authorization
Required for Buildine Permit
The construction and installation requirements of Rules .1950, .1957, .1954, .195S, .19S6, .1957, .19SS. and .1959 are incorporated by references into this permit and shall be met Systems shall be installed in accordance
with the attached system layout
ISSUED TO: 4e11A-L ik TAh-00 -ttJG PROPERTY LOCATION: ;�r-0745 OJIZ��
C SUBDIVISION QUA( LOT # 14—
Facility
4_Facility Type: 5 /New CK Expansion ❑ Repair
Basement? ❑ Yes No Basement Fixtures? ❑ Yes 19 No
Type of Wastewater System" 1�74X�- (Initial) Wastewater Flow: LIR (0 GPD
(See note below, if applicable ❑)
(Repair)
Installation Requirements/Conditions Number of trenches
Septic Tank Size o O gallons Exact length of each trench Ob feet
Pump Tank Size 200 gallons Trenches shall be installed on contour at a
Maximum Trench Depth of. inches
(Trench bottoms shall be level to +/-1/4"
in all directions)
Pump Requirements: —ft. TOM vs. GPM
Conditions:
Trench Spacing: T Feet on Center
Soil Cover: --i�—nches
(Maximum soil cover shall not exceed
36' above the trench bottom)
inches below pipe
Aggregate Depth: 2 inches above pipe
WATER LINES (IN(LUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA.
NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA.
/Z inches total
**If applicable: / understand the system type specified it different from the type specified on the application. / accept the specifications o/ thin permit.
Owner/Legal Representative Signature: Date:
This Construction Authorization is subject to revoarion if the site plan, plat or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This
construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit l[[ AI IALntV lilt )Rtlltl
Authorized State en • Date:
Construction Authorization Expiration Date: — ZZ
HTE# I 7 —5-- POD
Permit # 292 1
Harnett County Department of Public Health
Site Sketch
PROPERTY LOCATON: 5k2171 S I-�Xht iT�,r {�,`
ISSUED TO: &'Ir. RIrQn. z SUBDIVISION (;`,;ZOO(�- 0 LOT # _q
Authorized State
,.70 p eptfi V
vv A4 1-1
-v
/D
i
bLtJiG�' �,•
Department of Environment, Health and Natural Resources
Division of Environmental Health
On -Site Wastewater Section
SOIL/SITE EVALUATION
for ON-SITE WASTEWATER SYSTEM
Owner: Applicant:
Address: Date Evaluated:
Proposed Facility: ` �,(� Design Flow (. I 949q'0q'Z—)
Location of Site: Property Recorded:
Water Supply: Public❑ Individual ❑ Well
Evaluation Metho Auga6�BBori�n El Pit F-1Cut
Type of Wastewater: ('Sewage ❑ Industrial Process
Sheet:
Property ID:
Lot #:
File #:
Code:
Property Size:
❑ Spring
❑ Mixed
❑ Other
P
R
O
F
1
L
E
#
.1940
Landscape
Position/
Slope%
Horizon
Depth
(In.)
SOIL MORPHOLOGY
.1941
OTHER
PROFILE FACTORS
Profile
Class
& LTAR
.1941
Structure/
Texture
.1941
Consistence
Mineralogy
.1942
Soil
Wetness/
Color
.1943
Soil
Depth (R4.)
.1956
Sapro
Class
.1944
Restr
Horiz
%1 L
�-Z10t
U- e16
5 -
yw
Description Initial Repair System Other Factors (.1946):
System Site Classification (.1948): r>5
Available S ace (.1945) Evaluated By;--,,�
System Type(s) Others Present"
Site LTAR r.ce