Loading...
FM REVIEW Harnett i C R T NYA 1 (F lr o tma gattySerrices Dope mount ,en wweJ�ansaft orp Plan Review, Inspection and Permit Fees Application Number 09- 50022450 $150.00 ❑ Explosive Mat. (90 Days) $ 75.00 ❑ Explosive Mat. (72 Hrs) $ 25.00 ❑ Fireworks Public Display $ 35.00 ® Final Inspection $ 35.00 +2.00 per device ❑ Fire Alarm Testing $ 35.00 + 2.00 per nozzle ❑ Fixed Fire Suppression $ 25.00 ❑ Insecticide Fog/Fumigation $ 50.00 ❑ Pipe Test/UST /AGST $ 50.00 ❑ Plans up to 5000 ft $100.00 Plans 5001 ft to 10,000 ft $150.00 n Plans 10,001 ft to 25,000 ft $250.00 n Plans 25,001 ft and over $ 35.00 + 2.00 per Head ❑ Sprinkler Certification Test $ 35.00 ❑ Standpipe Testing $ 25.00 n Special Assembly $ 25.00 ❑ Temporary Kiosks /Displays $ 25.00 ❑ Tents, Canopies, Air Supported $ 50.00 n Tank Installation (charge for each tank) $ 50.00 ❑ Tank Removal (charge for each tank) $ 135.00 Total n/a Total device /heads Michael L. Marti 11/18/10 Code Enforceme e ' icial Date 3 1 Harnett K"s " C d U N TY Immo:my SakeDeportment d5k a n MOR7i+ CARS tINA �� (. Deportment wuwJ�aroatt.mg November 18, 2010 Brad Simpson David H. Simpson Construction Company 513 Wicker Street Sanford, NC 27330 Ruhl Tech Engineering — Phase 1 26 Mockingbird Lane Spring Lake, NC 28390 Application Number 09- 50022450 Mr. Simpson, Thank you for submitting the plans for the alteration and addtion. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 906.1 Fire Extinguishers o Fire extinguishers shall be placed in approved locations as drawn by the code enforcement official on the approved plans. o The fire extinguishers provided shall have a minimum rating of 2A 10B:C and shall not be installed higher than 5 feet above the finished floor. • 505.1 Physical Address o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and /or parking lot. o The numbers used to make up the physical address shall be at least 5 inches in height. ?S Harnett a r i s C o U N T r (Ns Emergency U nianDoperttmcnt NORTH CAROLINA wvmhm • 506.1 Knox Box o A secure key box shall be installed on the new building that houses all keys to all the doors within the building in which the fire department would need access to in the event of an emergency. o An order form is attached with the plan review letter o Install the Knox Box within a reasonable distance from the main entrance to the building. o All doors to the entire complex shall be identified by a red Knox Box sticker which must be ordered with the Knox Box. • 1019.1 Exit Door o The new occupancy is required to have at least two approved egress doors. The current space shows only one exit door and the travel distance exceeds that which is allowed for a building with one exit. Install an approved exit door and exit discharge that can adequately exit occupants out of the building to the public way. o Contact the Building Inspector's Office and Fire Marshal's Office before the installation of the exit door in order to receive approval for its location. • 1006.1 Emergency Lighting o The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. o Emergency Lighting and Exit Lighting shall be installed at the two exits (one existing and one new). o This is to include exterior exit discharge lighting. Thank you again for submitting the plans for the alteration and addition. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Again, thank you and we look forward to working with you during the construction period! Sincerely, Mic :el L. Martin Deputy Fire Marshal