Loading...
IPAC RHTE# I6 -s- �s6/ o HarnL _. County Department of Public a. _alth 2906 Improvement Permit A building permit cannot be issued with only an Improvement Permit'(' PROPERTY LOCATION:-S/L /T1 S Ckt,i r ILZ ISSUED TO: �� SUBDIVISION LOT # NEW REPAIR 0EXPANSION ❑ Type of Structure: Proposed Wastewater System Type: 2Z5-"2UC�-- Projected Daily Flow: L� GPD Number of bedrooms: Number of Occupants: max Basement ❑Yes No Site Improvements required prior to Construction Authorization Issuance: Pump Required: Yes ❑ No ❑ Ma required based on final location and elevations of facilities Type of Water Supply: El Community Public ❑ Well Distance from well het Permit conditions: Permit valid for. lstive years ❑ No expiration Authorized Sta ent: L V Date: 9 -7.! iE% SEE ATTACHED SITE SKETCH The issuance of this permit by a lealth Department in no way guannrees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation ij site plan, plat or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and in conditions of this permit. Construction Authorization Recruited for Buildine Permit The mnstmction and installation requirement of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references imus this permit and shall be met Systems shall be installed in accordance with the attached system layout. ,�,/�j Q___� ISSUED TO66& �)tZb/ �- PROPERTY LOCATION: 25-),-J-7-7 c. SUBDIVISION LOT # Facility Type: New xpansion ❑ Repair Basement? ❑ Yes No Basement Fixtures? ElYes No Type of Wastewater System** -?---m (See note below, if applicable ❑) �y (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size /&C0-0 gallons Exact length of each trench h4 feet Tr Pump Tank Size T,6 gallons Trenches shall be installed on contour at a Sc Maximum Trench Depth of: , inches (Trench bottoms shall be level to +/•1/4" in all directions) (Initial) Wastewater Flow: 3-0 GPD ench Spacing:- feet on Center it Cover. —L—inches (Maximum soil cover shall not exceed 36" above the trench bottom) Pump Requirements: fL TDH vs. GPM Conditions: r;ri t bY- (x xs (J t%l l s3 / .. ,,o Aggregate Depth: 1' WATER LINES (INCLUDING IRRIGATION) MUST BE IOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. 6/c, inches below pipe Z inches above pipe 17 inches total **If applicable: / onderrtend the System type rpecifmed it different from the type speared on the application. / accept the spedfcadonr of this permit Owner/Legal Representative Signature: Date: This Construction Authorization is subject to revocameon if the site plan, plat or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization is Authorized with the provisions of the laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH Date: 13--171-16 Construction Authorization Expiration Date: HTE# �� _ ��l� d /Z Permit # 2 S e G- / Harnett County Department of Public Health Site Sketch _ PROPERTY LOCATON: oi« 2c� ISSUED TO: V1 1 ten -Ca n SUBDIVISION LOT # Authorized State A4ar-- %�/h JivT3 � Date: �— C( —/7 if ` I / z �k e! +I qo 6f9 y , ,_ Pce_c` iu0 ZS°c II � Qet.n.l,on i W �Iw IU a � p �yG Z ,ta ��lv `'kA S