Loading...
IPACHTE# Ido —5 — No3GU Harnett County Department of Public Health 29287 Improvement Permit A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: 4; pi n e 0nu rc to (1% C 5 2 15 -ib, ISSUED TO: T0` Cun54rvc.4;W Snc. SUBDIVISION LOT # JAre NEW 00" REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: 1(3 (L 5 r D Proposed Wastewater System Type: 25Yw tZz i,,r }'on f sFcm Projected Daily Flow: 24b GPD Number of bedrooms: — Z— Number of Occupants: of max Basement ❑Yes EX0 / Pump Required: ❑Yes 111 No 19May b4 required based on Final location and elevations of facilities Type of Water Supply: ❑ Community Public ❑ Well Distance from well feet Permit valid for. Dean Permit conditions: -Z F3r'sevv n �2ye a�) 5f 4e t4 ;A -„L Utl ❑ No expiration Authorized State Ageniv i S �` _��� _��y Date: t 2 - 7-C.)- /6 SEE ATTACHED SITE SKETCH The issuance of this permit by thpllealth Department in noway guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation i1 t(e* plan, plat or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit. Construction Authorization (Required for Building PermitJ The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be instilled in accordance with the attached system layout. ISSUED TO: -TOPROPERTY LOCATION: K-pl,e) Ckvrcl, RA. (52 tS',zGl SUBDIVISION T LOT # 4/2 Facility Type: 1-60- S D LYNew ❑ Expansion ❑ Repair Basement? ❑ Yes VNo Basement Fixtures? ❑ Yes ❑ No Type of Wastewater System" Z5 a/o rat A ,ca. 4 5> /-e n (Initial) Wastewater Flow: 2`/o GPD (See note below, if applicable ❑) Z5 i6 (&Aoc "a5 _ slt. (Repair) Installation Requirements/Conditions Number of trenches 2 Septic Tank Size wC.t1N) gallons Exact length of each trench --76 feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of: Z4 -Z�17 inches (Trench bottoms shall be level to +/_I/4" in all directions) Pump Requirements: ft. TDM vs. GPM Trench Spacing: 9 Feet on Center Soil Cover: t2 - /6 inches (Maximum soil cover shall not exceed 36" above the trench bottom) Aggregate Depth: Conditions: 2 Ge -6 foo -N (- 9o,t1.ZJ 54k M 'n .a rot WATER LINES (INCLUDING IRRIGATION) MUST BE ]OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. inches below pipe inches above pipe inches total "If applicable: / ondecdand the system type spe6fed is different from the type speciled on the application. / accept the rpecilrations of this permit Owner/Legal Representative Signature: Date: This construction Authorization u subject to revocation if the site plan, plat or the intended me changes. The Comnuction Authorization shall not be transferred when there is a change in ownership of the site. Thu lnmlmctlos Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH �.�W� Authorized State Agent: � Date: 6>�-'Lo--Gco onstruction Authorization Expiration Date: 2- HTE# 1(0 -S- 4 o30µ Permit # 2 g 2 8 Harnett County Department of Public Health Site Sketch PROPERTY LOCATON: K'i plrna CkQrr-L. (Ld-� S2 15-6j ISSUED TO: Cc,nslruJ, on Tn& SUBDIVISION LOT # Authorized State Agent"-L---'� Date: / II1,.4Z" I6�' SE-ci3Rc�S — I � lZ u \ � q l2 o � __ _ __ -43, J 0 PO 5 i $oxZ'8 I+OV5-5 4 K \ y � 86 o o \ O � d � e � \,I Department of Environment, Health and Natural Resources Division of Environmental Health On -Site Wastewater Section SOIUSITE EVALUATION for ON-SITE WASTEWATER SYSTEM Cp,I1'[ Owner: '�"hm Applicant: TO r Cf / ' I enc. Address: 1. qiZl'./�1, Ce tea. a-ADate Evaluated: 17- /1 Proposed Facility: 55 - 51 o Design Flow (.1949): Zvv 7 lal. Location of Site:ej/;�, Zy„W r / - Property Recorded:XL -f Water Supply: ublic❑ Individual ❑ Well Evaluation Method: Auger Boring ❑ Pit ❑ Cut Type of Wastewater: R'Sewage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: U. �-3 /jC - ❑ Spring ❑ Other ❑ Mixed P R O F 1 L E # .1940 Landscape Position/ Slope% Horizon Depth (In.) SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS Profile Class & LTAR .1941 Structurev Texture .1941 Consistence Mineralogy 1942 Soil Wemess/ Color .1943 Soil Depth W. .1956 Sapro Class .1944 Restr Horuz l -L L 1 `ry LZ G, - SL i�r SiSP jL�1 S 0- ZO Gr. 5 L rf 55Se 5 1 S off L+5 �- 0 Description Initial Repair System Other Factors (.1946): S stem Site Classification (.1948): Available Space (.1945) V, Evaluated By: System Te(s) Z5Others Present: �.c .nc5 nt rte Site LTAR O