Loading...
IPACHTE# Harnett County Department of Public Health 29113 Imorovement Permit A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: G R2c R,v ISSUED TO: W4Z'-L-3_5 OEsNC.Nv du a z-9 SUBDIVISION GuracL L_GhmTc,Tsna.t LOT # 3'8 NEW)< REPAIR ❑ PANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: (5$n56J Proposed Wastewater System Type: 7.S'/e PrcOUG:v o N Y>>CM Projected Daily Flow: 3fo0 GPD Number of bedrooms: 3 Number of Occupants: —C -max Basement ❑YesXNo Pump Required: []Yes ❑ No -(May be required based on final location and elevations of facilities Type of Water Supply: ❑ Community ;K Public ❑ Well Distance from well t O O feet Permit valid for. 'rs/five years Permit conditions: ❑ No expiration Authorized State Agent:: l _ Date: \ S 10 L SEE ATTACHED SITE SKETCH The issuance of this permit by the Health Department m no way guarantees t:;4' " este of other permits. The permit holder is respell Bible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Imp, ment Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED T0: 'NA CJ. Ls i)esv G H a u I Lo PROPERTY LOCATION: C z_Pg2�L K.D SUBDIVISION CuLOT # 3i Facility Type: G isD 'ted '+5'GD New ❑ Expansion ❑ Repair Basement? ❑ Yes 'C� No Basement Fixturry7 ❑ Yes IrkNo Type of Wastewater System** aS a/oy.EOvyc L n fI Sy Z. ; C—.M (Initial) Wastewater Flow: 34 O GPD (See note below, if applicable ❑) b�o W'60• SyS_ (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size s o o is gallons Exact length of each trench "7 C feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of: 1`d inches (Trench bottoms shall be level to +/-1/4" in all directions) Pump Requirements: h. TON vs. GPM Conditions: Trench Spacing: c) Feet on Center Soil (over. Ce inches (Maximum soil cover shall not exceed 36" above the trench bottom) Aggregate Depth: WATER LINES (INCLUDING IRRIGATION) MUST BE IOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. inches below pipe inches above pipe inches total **If applicable: / amderstand the system type speciled is different from the type rpeciled on the app/ication. / accept the rp inih'cadoar of this permit. Owner/Legal Date: This Construction Authorization is su 1 evocation if the site plan, plat or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction AutMrization is t m mmplian r ns of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH Authorized State Agent ,U}i5 Date: 11))0111;' o�jon Authorization Expiration Date: tv 110 1 NTE# «S 3i °ILIa, Permit # QLG0 )3 Harnett County Department of Public Health Site Sketch PROPERTY LOCATON: Ct-9161`4— ISSUED TO: G t9// SUBDIVISION GUc7,CL\ ti �A s t 0 d LOT # 3� Authorized State Agent: �6> �Ql l Y l� iOl F59O Date: W o' 16 too Department of Environment, Health and Natural Resources Division of Environmental Health On -Site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: Address: Date Evaluated: Proposed Facility: jL, �, (�� Design Flow (.1949}73- ,C Location of Site: _�1.. Property Recorded: Water Supply: public❑ Individual ❑Well Evaluation Method;�qu Boring ❑ pit ❑ Cut Type of Wastewater: Sewage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: ❑ Spring ❑ Mixed ❑ Other P R O F I SOI, MORPHOLOGY .1940 OTHER L Landscape Horizon .1941 PROFILE FACTORS E # PositioN Depth1941 Slope % (In.) . Structure/.1943 1941 Consistence .1942 Soil Wetness/ .1943 .1956 Profile Texture M, 10 Colar IN Salim Class Restr Class Horiz G sL v��rl� & LTAR cz, P -L 55)T C-� I„ P 1 OIS G st V?:2.���tr Description Available Initial Repair System Other Factors (.1946): / S ste Site Classification (.1948): ' S ace 1945) . S stem T s) Evaluated By: CK Site LTAR Others Present: