Loading...
COMMERCIAL LAND USE NAME: CEDAR RUN CAPITAL,LLC APPLICATION a:JL -J tMiOD13 *This application to he filled out when applying for a septic system inspection.* County Health Department Application for Improvement Permit and/or Authorization to Construct IF THE INFORMATION IN THIS APPLICATION IS FALSIFIED.CHANGED,OR THE SITE IS ALTERED THEN THE IMPROVEMENT PERMIT OR AUTHORIZATION TO CONSTRUCT SHALL BECOME INVALID. The permit is valid for either 61.I months or without expiration depending upon documentation submitted. (Complete site plan=60 months:Complete plat=without expiration) 910-893-7525 option I CONFIRMATION if X Environmental Health New Septic SystemCode 800 • All property Irons must be made visible. Place 'pink properly flags" on each corner iron of lot. All property lines must be clearly flagged approximately every 50 feet between corners. • Place"orange house corner flags'at each corner of the proposed structure. Also flag driveways, garages,decks, out buildings,swimming pools,etc. Place flags per site plan developed at/for Central Permitting. • Place orange Environmental Health card in location that is easily viewed from road to assist in locating property. • If property is thickly wooded, Environmental Health requires that you clean out the undergrowth to allow the soil evaluation to be performed. Inspectors should be able to walk freely around site. Do not grade property. • All lots to be addressed within 10 business days after confirmation. $25.00 return trip fee may be Incurred for failure to uncover outlet lid, mark house corners and property lines. etc. once lot confirmed ready. • After preparing proposed site call the voice permitting system at 910-893-7525 option I to schedule and use code 800 (after selecting notification permit if multiple permits exist) for Environmental Health inspection. Please note confirmation number given at end of recording for proof of request. • Use Click2Gov or IVR to verify results. Once approved, proceed to Central Permitting for permits. Environmental Health Existing Tank Inspections Code 800 • Follow above instructions for placing flags and card on property. • Prepare for inspection by removing soil over outlet end of tank as diagram indicates, and lift lid straight up (if possible) and then put lid back In place. (Unless inspection is for a septic tank in a mobile home park) • DO NOT LEAVE LIDS OFF OF SEPTIC TANK • After uncovering outlet end call the voice permitting system at 910-893-7525 option 1 8 select notification permit if multiple permits, then use code 800 for Environmental Health inspection. Please note confirmation number given at end of recording for proof of request. • Use Click2Gov or IVR to hear results. Once approved, proceed to Central Permitting for remaining permits. SEPTIC If applying for authorization to construct please indicate desired system type(s): can be ranked in order of preference,must choose one. II Accepted t 3 I Innovative I L 1 Conventional 14I Any 12 I Alternative t_I Other_____ The applicant shall notify the local health department upon submittal of this application if any of the following apply to the property in question. If the answer is"yes",applicant MUST ATTACH SUPPORTING DOCUMENTATION:-SITE PLANS ATTACHED I—IYES XI NO Does the site contain any Jurisdictional Wetlands? -SOIL EVALUATION REPORT ATTACHED 1_IYES IX)NO Do you plan to have an irrigation system now or in the future? • I2f IYES I—I NO Does or will the building contain any drain!Please explain. Ober ohfrri - £iihnk 1 )aM Q I—IYES IX_I NO Are there any existing wells,springs,waterlines or Wastewater Systems on this property? I_I YES ix l NO Is any wastewater going to be generated on the site other than domestic sewage? IYES IXI NO Is the site subject to approval by any other Public Agency? t X IYES I—I NO Are there any Easements or Right of Ways on this property? SEE ATTACHED PLAT(PB2017 PG 14) I—IYES IXI NO Does the site contain any existing water,cable,phone or underground electric lines? H yes please call No Cuts at 800-632-4949 to locate the lines. This is a free service. I Have Read This Application And Certify That The Information Provided Herein Is True,Complete And Correct. Authorized County And State Officials Are Granted Right Of Entry To Conduct Necessary Inspections To Determine Compliance With Applicable Laws And Rules. I Understand That I Am Solely Responsible For The Proper Identification And Labeling Of All Property Lines And Corners And Making The Site Accessible o That A Complete lie Evaluation Can Be Performed. G. d,t.1es icy ,.,rte_ W 7 PROPERTY OWNERS OR OW RS LE JAL REPRESENTATIV „IGNATURE(REQUIRED) DATE 10/10 HAL OWEN & ASSOCIATES, INC. SOLI, & ENVIRONMENTAL SCIENTISTS P.O. Box 400, Lillington NC 27546-0400 Phone (910) 893-8743 / Fax (910) 893-3594 www.halowensoil.com 22 November 2016 Mr. C. Tyrus Clayton Draper Aden Associates 46 W. Washington Street Coats, NC 27521 Reference: Preliminary Report for Minor Subdivision—Two Lots The Retail Center Property Dear Mr. Clayton, A preliminary soil investigation has been conducted at the above referenced property, located on the southern side of Highway US 421, Upper Little River Township, Harnett County, North Carolina. The purpose of the investigation was to determine the ability of each lot to support a subsurface sewage waste disposal system and repair area for a commercial facility with a maximum daily effluent flow of 250 gallons. All soil ratings and determinations were made in accordance with "Laws and Rules for Sewage Treatment and Disposal Systems, 15A NCAC 18A .1900". It is our understanding that individual septic systems and public water supplies will be utilized at this site. the maximum building footprint used for this evaluation was 80 X 104 feet. Wetlands were not observed at this site. However the lower portion of the site is not well drained and artificial drainage improvements may be necessary. A portion of each lot was investigated and found to be underlain by soils rated as suitable and provisionally suitable for subsurface sewage waste disposal. Suitable soils are deep, well drained sandy textured soils that appear adequate to support long term acceptance rates of 0.6 gal/day/sgft. The provisionally suitable soils were observed to be friable and firm sandy clay loans to greater than 30 inches and appear adequate to support long term acceptance rates of 0.4 to 0.5 gal/day/sqft. It appears that the soils on each lot are adequate to support a conventional septic system and repair area for one business. The lot on the eastern side has significant potential to utilize a gravity driven conventional type septic system. The lot on the western side appears to have limited amounts of usable soils and although conventional drainlines can be expected, a pump will almost certainly be required to move the effluent uphill from the building to the drainfield. Soil Science Investigations • Wetland Delineations, Permitting, and Consulting ITAL OWEN & ASSOCIATES, INC. This soil investigation report and map, when provided to the Harnett County Health Department, should allow them to sign the maps for recordation. I appreciate the opportunity to provide this service and hope to be allowed to assist you again in the future. If you have any questions or need additional information, please contact me at your convenience. creeO gOIL SCF O��' tp�. �K'F,�, �'� Sinceerreell^ly,/////,j/ �/. `/�� , //orf �/ &! "_ t,,�A! = 1,4LI Hal Owen 'ATF R02 Ppm Licensed Soil Scientist OfMORTt';C' Soil Science Investigations • Wetland Delineations, Permitting, and Consulting HAL OWEN & ASSOCIATES, INC. Preliminary Report for Minor Subdivision—Two Lots The Retail Center Property 22 November 2016 Soil Map Legend 4 >*• Suitable and c Provisionally Suitable Soils t ��- r , w � I . �� Joh9rii �. rl 1 Distances are paced _ m qs a , 1I1 and approximate �, , a y 2 l i i 1 - t - Il b yy III 1, r r Ii i '� Ic - Spit — I I �p 1F r a �JyyCS �.1 i/i �� ( ; 'f Vii _ N-----)`''/1/1141; lal z �c� w I I t r n go I i f tg 3£s }; t Y i � ami& ac t � A p4. 1 Soil Science Investigations • Wetland Delineations, Permitting, and Consulting