Loading...
INSPECTIONS PREPARED 5/27/10, 14:33:11 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 5/28/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 SBDR 4BATH SFD CRAWL FLOOD ZONE - FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW TANK WATER SUPPLY • NEW WELL PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 5/28/10 TI R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5 AP VII- T /S: 05/27/2010 09:42 AM VBROWN COMMENTS AND NOTES COMMENTS AND NOTES • ( In Sto D0.11" roo- .Z r": —VOA (ov, c r ,;,ti PREPARED 6/07/10, 14:22:48 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 6/08/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 5BDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING' NEW TANK WATER SUPPLY • NEW WELL PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 TI ADDRESS CONFIRMATION VRU #: 001937515 B103 01 6/08/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 - &in At- COMMENTS AND NOTES ( L.40(\ Day. ) o r 00.+74 CI ovNil a1'ov� PREPARED 6/11/10, 14:20:47 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 6/14/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD., 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 SBDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • NEW WELL PERMIT: CPS! 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 TI ADDRESS CONFIRMATION VRU #: 001937515 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 TI R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001939644 (y .10 T /S: 06/10/2010 03:07 PM VBROWN COtM4ENTS AND NOTES PREPARED 6/15/10, 14:24:35 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR 1 DATE 6/16/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 SBDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING? NEW TANK WATER SUPPLY • NEW WELL PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 TI ADDRESS CONFIRMATION VRU #: 001937515 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001939644 6/14/10 AP T /S: 06/10/2010 03:07 PM VBROWN T /S: 06/14/2010 12:58 PM MREARIC 3105 01 6/16/10 TI R *OPEN FLOOR VRU #: 001941111 CO' G' (o AP— Nib COMMENTS AND NOTES r e r u fl au•w-- PREPARED 7/22/10, 13:57:28 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 7/23/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - ( - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 SBDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • NEW WELL PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 FB ADDRESS CONFIRMATION VRU #: 001937515 6/17/10 AP T /S: 06/17/2010 11:47 AM FBURGESS 387 ROBERTS RD SANFORD, NC 27332 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001939644 6/14/10 AP T /S: 06/10/2010 03:07 PM VBROWN T /S: 06/14/2010 12:58 PM MREARIC B105 01 6/16/10 MR R *OPEN FLOOR VRU #: 001941111 6/16/10 AP T /S: 06/16/2010 01:19 PM MREARIC R427 01 7/23/10 y�) FOUR TRADE ROUGH IN >2500 VRU #: 001958099 71f23•4) ( / / / t COMMENTS AND NOTES PREPARED 7/29/10, 13:59:22 INSPECTION TICKET PAGE 4 He INSPECTOR: IVR I DATE 7/30/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : - PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - -- APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 SBDR 4BATH SFD CRAWL ,."'n FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE . . . . . . . : -SFD SEPTIC - EXISTING ? ?.`... . . : NEW TANK WATER SUPPLY . . . . . ... :.NEW WELL A PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 FE ADDRESS CONFIRMATION VRU #: 001937515 6/17/10 AP T /S: 06/17/2010 11:47 AM FBURGESS 387 ROBERTS RD SANFORD, NC 27332 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001939644 6/14/10 AP T /S: 06/10/2010 03:07 PM VBROWN T /S: 06/14/2010 12:58 PM MREARIC 3105 01 6/16/10 MR R *OPEN FLOOR VRU #: 001941111 6/16/10 AP T /S: 06/16/2010 01:19 PM'- MREARIC R427 01 7/23/10 JH FOUR TRADE ROUGH IN >2500 VRU . #: 001958099 7/23/10 DP `SMissing nuts & washers on anchor bolts in garage..0 Need stud under break in top plate'over garage door.`9.)Need 24" straps on breaks in top plate within 24 ", to right of panel in garagg:XpC lvls in kitchen need to be bolted together per note 6 on plans'Need to strap top plates in bay in breakfast nook 24" min :6?'9�lvls ® bay in breakfast nook needto be bolted together per note 6 on plans.t Fire caulk water lines @ top plate in breakfast nook to right of - arch.8)Fire caulk water line ® top plate to right of pantry door in kitchen:511.Fire caulk water lines p top plate on garage wall in dining room.'t 7Missing nails in floor joist hanger in dining room.n441eed triple stud'under beam for loony in living room. P.1 12)Window to left of door in family room needs to be tempered.13)Need gas line test for fire place.14)Fire caulk 3" pipe M top plate in master bathroom ® shower & nail all holes in structual nail guard.15)Fire caulk water lines in CONTINUED ONTO NEXT PAGE PREPARED 7/29/10, 13:59:22 INSPECTION TICKET PAGE 5 Harnett INSPECTOR: IVR DATE 7/30/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : - PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS master bathroom © top plate over sink.16)Missing stud to right of master bath door.DO NOT SIDE OR INSULATE THIS INSPECTION IS TERMINATED ON FIRST FLOOR TO MANY VIOLATIONS. PAY $50 RE FEE P.2 R427 02 7/30/10 TI FOUR TRADE ROUGH IN >2500 VRU #: 001961112 7 3ra• 4 54-1411 COMMENTS AND NOTES o K 7 , S -F (u.s. PREPARED 8/13/10, 14:23:58 INSPECTION TICKET PAGE 1 - Harnett Count IVR DATE 8/16/10 ADDRESS . : 387 ROBERT° RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835= -CP- NEW - RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14M1, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82134 SBDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING? NEW TANK WATER SUPPLY • NEW WELL PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 FB ADDRESS CONFIRMATION VRU #: 001937515 6/17/10 AP T /S: 06/17/2010 11:47 AM FBURGESS 387 ROBERTS RD SANFORD, NC 27332 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 00/937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001939644 6/14/10 AP T /S: 06/10/2010 03:07 PM VBROWN T /S: 06/14/2010 12:58 PM MREARIC B105 01 6/16/10 MR R *OPEN FLOOR VRU #: 001941111 6/16/10 AP T /S: 06/16/2010 01:19 PM MREARIC R427 01 7/23/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001958099 7/23/10 DP 1)Missing nuts & washers on anchor bolts in garage.2)Need stud under break in top plate over garage door.3)Need 24" straps on breaks in top plate within 24 ", to right of panel in garage.4)4 lvls in kitchen need to be! bolted together per note 6 on plans.5)Need to strap top plates in bay in breakfast nook 24" min.6)3 lvls @ bay in breakfast nook needto be bolted together per note 6 on plans.7)Fire caulk water lines @ top plate in breakfast nook to right of arch.8)Fire caulk water line @ top plate to right of pantry door in kitchen.9)Fire caulk water lines'@ top plate on garage wall in dining room.10)Missing nails in floor joist hanger in dining room.11)Need triple stud under beam for balcony in living room. P.1 12)Window to left of door in family room needs to be tempered.13)Need gas line test for fire place.14)Fire caulk 3" pipe @ top plate in master bathroom @ shower & nail all CONTINUED ONTO NEXT PAGE PREPARED 8/13/10, 14:23:58 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 8/16/10 ADDRESS . : 387 ROBERTG RD S SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS holes in structual nail guard.15)Fire caulk water lines in master bathroom ® top plate over sink.16)Missing stud to right of master bath door.DO NOT SIDE OR INSULATE THIS INSPECTION IS TERMINATED ON FIRST FLOOR TO MANY VIOLATIONS. PAY $50 RE FEE P.2 R427 02 7/30/10 FOUR TRADE ROUGH IN >2500 VRU #: 001961112 7/30/10 DA T /S: 07/30/2010 12:01 PM MREARIC temp window needed by back door on final strap A -04 per specs install collar ties flashing H824 01 8/09/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001967504 8/09/10 AP T /S: 08/10/2010 10:06 AM SZIMMER T /S: 08/10/2010 10:07 AM SZIMMER I129 01 8/16/10 TI R *INSULATION INSPECTION VRU #: 001969668 R - ( wo DA -14R R427 03 ^ 8/16/10 TI �7 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001969849 X•( 6•j0 AI T /S: 08/13/2010 02:23 PM NTART COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillina on, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 08 -16 -10 PERMIT # 09- 50022835 ADDRESS: 387 roberts rd. Violations: 1. Frame in around the stove vent and fireblock the area per code 2. Call for insulation re- inspection when ready Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 5(17/10, 14:02:53 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 8 /18 /10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14MI, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 5BDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW TANK WATER SUPPLY . . . . . : NEW WELL PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 FB ADDRESS CONFIRMATION VRU #: 001937515 6/17/10 AP T /S: 06/17/2010 11:47 AM FBURGESS 387 ROBERTS RD SANFORD, NC 27332 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001939644 6/14/10 AP T /S: 06/10/2010 03:07 PM VBROWN T /S: 06/14/2010 12:58 PM MREARIC B105 01 6/16/10 MR R *OPEN FLOOR VRU #: 001941111 6/16/10 AP T /S: 06/16/2010 01:19 PM MREARIC R427 01 7/23/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001958099 7/23/10 DP 1)Missing nuts & washers on anchor bolts in garage.2)Need stud under break in top plate over garage door.3)Need 24" straps on breaks in top plate within 24 ", to right of panel in garage.4)4 lvls in kitchen need to be'.bolted together per note 6 on plans.5)Need to strap top plates in bay in breakfast nook 24" min.6)3 lvls @ bay in'],breakfast nook needto be bolted together per note 6 on plans.7)Fire caulk water lines @ top plate in breakfast nook to right of arch.8)Fire caulk water line @ top plate to right of pantry door in kitchen.9)Fire caulk water lines,@ top plate on garage wall in dining room.10)Missing nails in floor joist hanger in dining room.11)Need triple stud under beam for balcony in living room. P.1 12)Window to left of door in family room ' :needs to be tempered.13)Need gas line test for fire place.14)Fire caulk 3" pipe @ top plate in master bathroom @ shower & nail all holes in structual nail guard.15)Fire caulk water lines in CONTINUED ONTO NEXT PAGE PREPARED 5/17 /1$, 14:02:53 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 8/18/10 ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ,master bathroom @ top plate over sink.16)Missing stud to right of master bath door.DO NOT SIDE ORIINSULATE THIS INSPECTION IS TERMINATED ON FIRST FLOOR TO MANY VIOLATIONS. PAY $50 RE FEE P.2 R427 02 7/30/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001961112 7/30/10 DA T /S: 07/30/2010 12:01 PM MREARIC . window needed by back door on final strap A -04 per specs install collar ties flashing H824 01 8/09/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 IVRU #: 001967504 8/09/10 AP T /S: 08/10/2010 10:06 AM SZIMMER T /S: 08/10/2010 10:07 AM SZIMMER I129 01 8/16/10 MR R *INSULATION INSPECTION VRU #: 001969668 8/16/10 DA T /S: 08/16/2010 11:06 AM MREARIC frame around the stove vent pipe and fireblock per code at that area R427 03 - 8/16/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001969849 8/16/10 AP T /S: 08/13/2010 02:23 PM NTART T /S: 08/16/2010 12:23 PM MREARIC I129 02 8 /18 /10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001971191 SC- (R -K9 )1 P '(tlAL, T /S: 08/17/2010 01:20 PM RDCONTE COMMENTS AND NOTES PREPARED 10/04/10, 13:59:35 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 10 /05 /10 ADDRESS . 387 ROBERTS RD SUBDIV: Il l s CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE :! PARCEL . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS master bathroom ® top plate over sink.16)Missing stud to right of master bath door.DO NOT SIDE OR INSULATE THIS INSPECTION IS TERMINATED ON FIRST FLOOR TO MANY VIOLATIONS. PAY $50 RE FEE P.2 R427 02 7/30/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001961112 7/30/10 DA T /S: 07/30/2010 12:01 PM MREARIC temp window needed by back door on final strap A -04 per specs install collar ties flashing, H824 01 8/09/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001967504 8/09/10 AP T /S: 08/10/2010 10:06 AM SZIMMER T /S: 08/10/2010 10:07 AM SZIMMER I129 01 8/16/10 MR R *INSULATION INSPECTION VRU #: 001969668 8/16/10 DA T /S: 08/16/2010 11:06 AM MREARIC frame around the stove vent pipe and fireblock per code at that area R427 03 8/16/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001969849 8/16/10 AP T /S: 08/13/2010 02:23 PM NTART T /S: 08/16/2010 12:23 PM MREARIC I129 02 8/18/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001971191 8/18/10 AP T /S: 08/17/2010 01:20 PM RDCONTE T /S: 08/18/2010 12:50 PM MREARIC M305 01 10/05/10 TI R *PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 001989755 /G • c'- J GP'M , T /S: 10/04/2010 01:42 PM NTART P307 01 10/05/10 TI R *PLUMB WATER CONNECTION TIME: 17:00 VRU #: 001989763 - -S J - -' c T /S: 10/04/2010 01:42 PM NTART COMMENTS AND NOTES PREPARED 10/06110, 14:53:22 INSPECTION TICKET PAGE 4 Harnett+►oun,_ INSPECTOR: IVR DATE 10/07/10 s AP ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER'BRADLEY A & HYANG C PHONE : PARCEL . . -' 03 -9597- - -0129- - - - .1 APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/15/2009 08:29 AM VBROWN - - -- !, PROPERTY ON CORNER OF SR# 2158 ROBERTS RD AND A DIRT RD CALLED CHURCHILL RD WITH DRIVEWAY ON ROBERTS ROAD. 27W 14M1, LEFT ON BUFFALO LAKE RD 1.9 MI, RIGHT ON ROBERTS RD GO TO SECOND DIRT RD ON LEFT, PROPERTY ON CORNER OF ROBERTS RD AND CHURCHILL RD. STRUCTURE: 000 000 82X34 SBDR 4BATH SFD CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 5.00 PROPOSED USE . . . . : SFD SEPTIC - EXISTING NEW TANK WATER SUPPLY . . . . .,. . : NEW WELL PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 5/28/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001933522 5/28/10 AP T /S: 05/27/2010 09:42 AM VBROWN T /S: 05/28/2010 12:55 PM MREARIC A814 01 6/08/10 FS ADDRESS CONFIRMATION VRU #: 001937515 6/17/10 AP 7 /S: 06/17/2010 11:47 AM FBURGESS 387 ROBERTS RD SANFORD, NC 27332 B103 01 6/08/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001937523 6/08/10 AE T /S: 06/08/2010 12:37 PM MREARIC damp proof foundation install foundation drain B113 01 6/14/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 #: 001939644 6/14/10 AP T /S: 06/10/2010 03:07 PM VBROWN T /S: 06/14/2010 12:58 PM MREARIC B105 01 6/16/10 MR R *OPEN FLOOR VRU #: 001941111 6/16/10 AP T /S: 06/16/2010 01:19 PM MREARIC R427 01 7/23/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001958099 7/23/10 DP 1)Missing nuts & washers on anchor bolts!in garage.2)Need stud under break in top plate over garage door.3)Need 24" straps on breaks in top plate within 24"t to right of panel in garage.4)4 lvls in kitchen need to belbolted together per note 6 on plans.5)Need to strap top plates in bay in breakfast nook 24" min.6)3 lvls @ bay in! nook needto be bolted together per note 6 on plans.7)Fire caulk water lines @ top plate in breakfast nook to right of arch.8)Fire caulk water line @ top plateto right of pantry door in kitchen.9)Fire caulk water linesj@ top plate on garage wall in dining room.10)Missing nails in floor joist hanger in dining room.11)Need triple stud under beam for balcony in living room. P.1 12)Window to left of door in family roomineeds to be tempered.13)Need gas line test for fire place.14)Fire caulk 3" pipe @ top plate in master bathroom @'shower & nail all holes in structual nail guard.15)Fire caulk water lines in CONTINUED ONTO NEXT PAGE PREPARED 10/06 -410, 14:53:22 INSPECTION TICKET PAGE 5 Harnett _ ?bunr i ' INSPECTOR: IVR I DATE 10/07/10 i ADDRESS . : 387 ROBERTS RD SUBDIV: CONTRACTOR : PHONE : OWNER . . : SHEFFER BRADLEY A & HYANG C PHONE : PARCEL . . : 03 -9597- - -0129- - - APPL NUMBER: 09- 50022835 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS/COMMENTS I master bathroom @ top plate over sink.160Missing stud to right of master bath door.DO NOT SIDE OR INSULATE THIS INSPECTION IS TERMINATED ON FIRST FLOOR TO MANY VIOLATIONS. PAY $50 RE FEE P.2 R427 02 7/30/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 00196/112 7/30/10 DA T /S: 07/30/2010 12:01 PM MREARIC temp window needed by back door on final' strap A -04 per specs install collar ties flashing H824 01 8/09/10 OT ✓ENVIR. OPERATIONS PERMIT TIME: 17:00 1 VRU #: 001967504 8/09/10 AP T /S: 08/10/2010 10 :06 AM SZIMMER T /S: 08/10/2010 10:07 AM SZIMMER I129 01 8/16/10 MR R *INSULATION INSPECTION VRU #: 001969668 8/16/10 DA T /S: 08/16/2010 11:06 AM MREARIC frame around the stove vent pipe and fireblock per code at that area R427 03 8/16/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 I VRU #: 001969849 8/16/10 AP T /S: 08/13/2010 02:23 PM NTART T /S: 08/16/2010 12:23 PM MREARIC 1129 02 8/18/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001971191 8/18/10 AP T /S: 08/17/2010 01:20 PM RDCONTE T /S: 08/18/2010 12:50 PM MREARIC M305 01 10/05/10 MR R *PLUMB SEWER CONNECTION TIME: 17 :00 VRU #: 001989755 10/05/10 AP T /S: 10/04/2010 01:42 PM NTART T /S: 10/05/2010 01:02 PM MREARIC P307 01 10/05/10 MR R *PLUMB WATER CONNECTION TIME: 17 :00 VRU #: 001989763 10/05/10 AP T /S: 10/04/2010 01:42 PM NTART T /S: 10/05/2010 01:02 PM MREARIC R431 01 10/07/10 TI FOUR TRADE FINAL >2500 VRU #: 001990894 1 - Jo f(/ I COMMENTS AND NOTES I ' 4 , i *,, 4 County of Harnett • Building Inspections Department Planning Services .- ` Certificate " <of•C`om ' liance ` : '''Occu a : �« ' - p q P P ' Y X Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett .. County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the • various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: 4 Use Classification: (R >_,3 i • Permi Numbers Name: s e f e r ` . $ui lding: b q- Snr 22 fir 3S Electrical: • , Address: t� or - ', Insulation: �, Plumbing: 4 Mechanical: ! r ' ��� MFG Home: v Date: (©- 7,1 0 Building Official: 7 ri i I