INSPECTIONS PREPARED 4/19/10, 15:13:27 INSPECTION TICKET PAGE 53 Harnett County INSPECTOR: IVR DATE 4/20/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * * * * * * * * * * * * * *• * * * * * * * * * * * ** STRUCTURE: 000 000 76R65.25 4BDR 3.5BATH W GAR,DECR,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING? SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER . CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 TI R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 /tin* /0 Ace 04?._ T /S: 04/16/2010 11:50 AM NTART COMMENTS AND NOTES PREPARED 4/15/10, 13:59:20 INSPECTION TICKET PAGE 46 Harnett County INSPECTOR: IVR DATE 4/16/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PHI, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS - .00 PROPOSED USE • SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 TI R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 LA' 16 )O /�}6� - IVII>_ T /S: 04/15/2010 08:54 AM VBROWN ��— COMMENTS AND NOTES PREPARED 4/23/10, 13:58:45 INSPECTION TICKET PAGE 20 Harnett County INSPECTOR: IVR DATE 4/26/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : • PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * ** * ** * * * * ** * * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DEC &,CRAWL FLOOD ZONE - FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC 3103 01 4/26/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 t)-)._,J-,. ((j ''°" Mike Etowski 303 -4828 ��� COMMENTS AND NOTES n(& r U „de » /c b 8 , � (< 5s r ul G(� �o caufc , a PREPARED 5/03/10, 13:57:50 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 5/04/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * * * * * * * ** * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE - SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART 3101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 • 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 T /S: 05/03/2010 11:44 AM NTART B103 02 5/04/10 TI R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 Nj ^ MR T /S: 05/03/2010 11:43 AM NTART TSP IS READY * * * *a* * * * * * * * * * * * * * * * * * * * *+ B105 01 5/04/10 TI R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 rj= £4(O A w. T /S: 05/03/2010 11:44 AM NTART COMMENTS AND NOTES PREPARED 6/21/10, 14:01:39 INSPECTION TICKET PAGE 18 Harnett' COunty INSPECTOR: IVR DATE 6/22/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * *** * * * * * * ** * * * * ** * * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76%65 -25 4BDR 3.5BATH W GAR,DBCK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART 96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 'MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP IS READY * * * *** * * * * * * * * * * * * * * * * * * * ** T /S: 05/04/2010 12:35 PM MREARIC 8105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC R427 01 6/22/10 TI FOUR TRADE ROUGH IN >2500 VRU #: 001943638 CONTINUED ONTO NEXT PAGE PREPARED 6/21/10, 14:01:39 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 6/22/10 • ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6 - I0 DA1j4 James Stovall 910 - 263 -0535 COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DA'Z'E: 06 -22 -10 PERMIT # 10- 50023990 ADDRESS: 96 crystal point VIOLATIONS: 1. Vent termination over roof is not high enough for 12/12 roof 2. Temp windows needed beside back door to porch 3. Leak at clean -out under tub 4. Truss H -2 needs straps at both ends 5. Joist under dryer has been over - notched 6. Ok to side but not insulate Harnett County Building Department Mike Rea ric cell# (910) 984- 4772 PREPARED 6/28/10, 13:59:34 INSPECTION TICKET PAGE 30 Harnett County1. — \ INSPECTOR: IVR DATE 6/29/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * ** * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART 96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP IS READY * * * * * * * * * * * * * * * * * * * * * * ** * ** T /S: 05/04/2010 12:35 PM MREARIC 3105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC R427 01 6/22/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001943638 CONTINUED ONTO NEXT PAGE PREPARED 6/28/10, 13:59:34 INSPECTION TICKET PAGE 31 Harnett County . INSPECTOR: IVR DATE 6/29/10 1 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6/22/10 DA James Stovall 910- 263 -0535 T /S: 06/22/2010 02:03 PM MREARIC 1. vent termination is not high enough for pitch r tempered windows needed beside double door to porch 3, leak at clean -oouot under master tub 4 truss H -2 needs straps on both ends 5. joist under dtryer has been over - notched 6. ok to side but not insulate R427 02 6/29/10 TI FOUR TRADE ROUGH IN >2500 VRU #: 001947282 C - 25 ■ic Ao_it Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 COMMENTS AND NOTES • HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 06 -29 -10 PERMIT # 10- 50023990 ADDRESS: 96 crystal pt. VIOLATIONS: 1. The piers under the over- notched joist at the dryer are not installed per code 2. The vent termination, according to the manufacturers instructions, on page 23, call for a minimum height (H) of 5' for a 12 on 12 roof pitch. From the lowest outlet point to the closest roof point, see diagram in installation booklet Re- inspection Fee $50.00 Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 7/01/10, 15:51:35 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 7/01/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * ** * * * * * * * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 3101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910- 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 3101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART 96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP IS READY * * * * * * * * * * * * * * * * * * ** * * * * * ** T /S: 05/04/2010 12:35 PM MREARIC B105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC CONTINUED ONTO NEXT PAGE PREPARED 7/01/10, 15:51:35 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 7/01/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R427 01 6/22/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001943638 6/22/10 DA James Stovall 910 - 263 -0535 T /S: 06/22/2010 02:03 PM MREARIC 1. vent termination is not high enough for pitch 2. tempered windows needed beside double door to porch 3, leak at clean -oouot under master tub 4. truss H -2 needs straps on both ends 5. joist under dtryer has been over - notched 6. ok to side but not insulate R427 02 6/29/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001947282 6/29/10 DP Mike Etowski 910- 303 -4828 James Stovall 910 - 263 -0535 T /S: 06/29/2010 01:08 PM MREARIC 1. the piers you installed under the notched joist under the dryer are not per code, no footer, no parging or mortar 2. according to the manuf. installation guide installation requires the lowest outlet point to be 5' above the roof when installed in a 12/12 roof R431 01 7/01/10 TI FOUR TRADE FINAL >2500 VRU #: 001948405 6/30/10 CA Mike Etowski 910- 303 -4828 James Stovall 910 - 263 -0535 R427 03 7/01/10 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001949304 1 - n L I P_adc T /S: 07/01/2010 03:51 PM NTART R431 02 7/01/10 MR FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001948637 7/01/10 CA T /S: 06/30/2010 02:30 PM JBROCK T /S: 07/01/2010 12:11 PM MREARIC this should be a rough T /S: 07/01/2010 03:51 PM NTART COMMENTS AND NOTES lir -3171' Functions Options Help — , ' 81 la It I S4 I 710 11201 0 3 5Z41 Application number 10 50023990 CPO 000 Application type CP NEW RESIDENTIAL [SFD) Tenant number, name NEEDS ZONING INSPECTION Permit type/seq/VRU CPSF 00 000802959 CP 'SR) IProperty address 96 CRYSTAI. POINT 03 Status Inspection Inspector Request Resul ts Date Description ID Date Time Stet Date 4/26/10 R*BLDG FOUND 8 TEMP SVC P MR 4/26/10 DR 4/26/10r 4/20/10 R*BLOG FOOTING / TEMP SVC MR 4/20/10 17:00 RP 4/20/10 4/16/18 R*BLDG FOOTING / TEMP SVC MR 4/16/10 17:00 AP 4/16/10 4/15/10 R*BLDG FOOTING / TEMP SVC VC 4/15/10 CA 4/15/10 • '1 °I< Emit I Cancel I Add inspection I , ' 4‘..3 - . 5.1)i.4 2 1. 7 :1, 4 ,1 " lialnehl County . iRequet Foglnspeiuon llnsp 51 bs10ry7 i llll ih ;1, '',nX I ut ilu Fu, tior Options HeIP .. . m, i �,. , y 11 Vig l t 1 H]6 770 12010 3 52:49 PM ; Application number 10 50023990 •000 000 ■ I Application Igpe + CP NEW RESIDENTIAL (SFDI Tenant number, name . NEEDS ZONING INSPECTION I , Permit tgpe /seq/VRU CPSF CO ' 000002959 CP' SFD 1Propertg address 96 CRYSTAL POINT- 03 '��` " .i I CII - ileIete Ji w Status Inspection Inspector Request Results t Date Description ID Date Time Stat Date - 7/01/10 FOUR TRADE FINAL >2500 MR 7/01/10 17:00 AP 7/01/10 6/30/10 FOUR TRADE FINAL >2505 TI 7/81/10 CA 6/30/10. 6/29/18 FOUR TRADE ROUGH IN >2508 MR 6/29/10 DP 6/29/10 6/22/10 FOUR TRADE ROUGH IN >2500 MR 6/22/10 DA 6/22/10 5/04/10 ADDRESS CONFIRMATION TW 5/04/10 17:00 AP 5/04/10 5/04/10 R +OPEN FLOOR MR 5/84/10 17:00 AP 5/04/10 " 5/04/10 R *BLDG FOUND 8 TEMP SVC P MR 5/04/10 17:00 AP 5/04/10 ' I. . I OK 1 Exit I , C!nce(I A9d inspection I rr PREPARED 7/12/10, 14:13:06 INSPECTION TICKET PAGE 17 Harnett SOuntr INSPECTOR: IVR DATE 7/13/10 ADDRESS E . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB I5 FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART 96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP IS READY * * * * * * * * * * * * * * * * * * * * * * * * * ** T /S: 05/04/2010 12:35 PM MREARIC 8105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC R427 01 6/22/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001943638 CONTINUED ONTO NEXT PAGE PREPARED 7/12/10, 14:13:06 INSPECTION TICKET PAGE 18 Harnett ;opnty, INSPECTOR: IVR DATE 7/13/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6/22/10 DA James Stovall 910 - 263 -0535 T /S: 06/22/2010 02:03 PM MREARIC 1. vent termination is not high enough for pitch 2. tempered windows needed beside double door to porch 3, leak at clean -oouot under master tub 4. truss H -2 needs straps on both ends 5. joist under dtryer has been over - notched 6. ok to side but not insulate R427 02 6/29/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001947282 6/29/10 DP Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 T /S: 06/29/2010 01:08 PM MREARIC 1. the piers you installed under the notched joist under the dryer are not per code, no footer, no parging or mortar 2. according to the manuf. installation guide installation requires the lowest outlet point to be 5' above the roof when installed in a 12/12 roof R431 01 7/01/10 TI FOUR TRADE FINAL >2500 VRU #: 001948405 6/30/10 CA Mike Etowski 910- 303 -4828 James Stovall 910 - 263 -0535 R427 03 7/01/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001949304 7/02/10 AP T /S: 07/01/2010 03:51 PM NTART T /S: 07/02/2010 08:14 AM NTART R431 02 7/01/10 MR FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001948637 7/01/10 CA T /S: 06/30/2010 02:30 PM JBROCK T /S: 07/01/2010 12:11 PM MREARIC this should be a rough T /S: 07/01/2010 03:51 PM NTART I129 01 7/12/10 TI R *INSULATION INSPECTION VRU #: 001952191 7/09/10 CA James Stovall 910 - 263 -0535 I129 02 7/13/10 TI R *INSULATION INSPECTION VRU #: 001952787 7 -(3_ /G ralk.Z James Stovall 910 - 263 -0535 COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 07 -13 -10 PERMIT # 10- 50023990 ADDRESS: 96 crown point VIOLATIONS: 1. 1. Provide me with the info on the insulation as installed . ie: what kind, brand, insulating value per inch. I cannot inspect if I don't know Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 7/15/10, 14:03:19 INSPECTION TICKET PAGE 14 HnettCounty INSPECTOR: IVR DATE 7/16/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART 96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP I5 READY * * * * * * * * * * * * * * * * * * * * * * * * * ** T /S: 05/04/2010 12:35 PM MREARIC B105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC R427 01 6/22/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001943638 CONTINUED ONTO NEXT PAGE PREPARED 7/15/10, 14:03:19 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR DATE 7/16/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6/22/10 DA James Stovall 910- 263 -0535 T /S: 06/22/2010 02:03 PM MREARIC 1. vent termination is not high enough for pitch 2. tempered windows needed beside double door to porch 3, leak at clean -oouot under master tub 4. truss H -2 needs straps on both ends 5. joist under dtryer has been over - notched 6. ok to side but not insulate R427 02 6/29/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001947282 6/29/10 DP Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 T /S: 06/29/2010 01:08 PM MREARIC 1. the piers you installed under the notched joist under the dryer are not per code, no footer, no parging or mortar 2. according to the manuf. installation guide installation requires the lowest outlet point to be 5' above the roof when installed in a 12/12 roof R431 01 7/01/10 TI FOUR TRADE FINAL >2500 VRU #: 001948405 6/30/10 CA Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 R427 03 7/01/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001949304 7/02/10 AP T /S: 07/01/2010 03:51 PM NTART T /S: 07/02/2010 08:14 AM NTART R431 02 7/01/10 MR FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001948637 7/01/10 CA T /S: 06/30/2010 02:30 PM JBROCK T /S: 07/01/2010 12:11 PM MREARIC this should be a rough T /S: 07/01/2010 03:51 PM NTART I129 01 7/12/10 TI R *INSULATION INSPECTION VRU #: 001952191 7/09/10 CA James Stovall 910 - 263 -0535 I129 02 7/13/10 MR R *INSULATION INSPECTION VRU #: 001952787 7/13/10 DA James Stovall 910- 263 -0535 T /S: 07/13/2010 01:36 PM MREARIC provide me with information on the insulation, what kind, how thick, etc. I129 03 7/16/10 TI R *INSULATION INSPECTION VRU #: 001954858 7 -(C - ,4P - -/VJc2_ Insulation Specs were in job box for previous inspection on 07 -13 -10 James Stovall Site contact 910 - 263 -0535 COMMENTS AND NOTES PREPARED 9/30/10, 14:02:21 INSPECTION TICKET PAGE 5 Harnett aunty 1 _ INSPECTOR: IVR DATE 10/01/10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB IS FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** * * * * * * * * * * * * * ** **** * * * * * * * * * * ** STRUCTURE: 000 000 76865.25 4BDR 3.5BATH W GAR,DECR,CRAWL FLOOD ZONE - FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIE: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART 8101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART V96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP Is READY * * * * * * ** * * * * * * * * * * * * * * * * * ** T /S: 05/04/2010 12:35 PM MREARIC 8105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC R427 01 6/22/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001943638 CONTINUED ONTO NEXT PAGE PREPARED 9/30/10, 14:02:21 INSPECTION TICKET PAGE 6 Harnett Cdunty S INSPECTOR: IVR DATE 10 /01 /10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6/22/10 DA James Stovall 910 - 263 -0535 T /S: 06/22/2010 02:03 PM MREARIC 1. vent termination is not high enough for pitch 2. tempered windows needed beside double door to porch 3, leak at clean -oouot under master tub 4. truss H -2 needs straps on both ends 5. joist under dtryer has been over - notched 6. ok to side but not insulate R427 02 6/29/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001947282 6/29/10 DP Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 T /S: 06/29/2010 01:08 PM MREARIC 1. the piers you installed under the notched joist under the dryer are not per code, no footer, no parging or mortar 2. according to the manuf. installation guide installation requires the lowest outlet point to be 5' above the roof when installed in a 12/12 roof R431 01 7/01/10 TI FOUR TRADE FINAL >2500 VRU #: 001948405 6/30/10 CA Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 R427 03 7/01/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001949304 7/02/10 AP T /S: 07/01/2010 03:51 PM NTART T /S: 07/02/2010 08:14 AM NTART R431 02 7/01/10 MR FOUR TRADE FINAL >2500 TIME: 17 :00 VRU #: 001948637 7/01/10 CA T /S: 06/30/2010 02:30 PM JBROCK T /S: 07/01/2010 12:11 PM MREARIC this should be a rough T /S: 07/01/2010 03:51 PM NTART I129 01 7/12/10 TI R *INSULATION INSPECTION VRU #: 001952191 7/09/10 CA James Stovall 910- 263 -0535 I129 02 7/13/10 MR R *INSULATION INSPECTION VRU #: 001952787 7/13/10 DA James Stovall 910- 263 -0535 T /S: 07/13/2010 01:36 PM MREARIC provide me with information on the insulation, what kind, how thick, etc. I129 03 7/16/10 MR R *INSULATION INSPECTION VRU #: 001954858 7/16/10 AP Insulation Specs were in job box for previous inspection on 07 -13 -10 James Stovall Site contact 910 - 263 -0535 T /S: 09/30/2010 01:52 PM NTART R431 03 9/27/10 TI FOUR TRADE FINAL >2500 VRU #: 001987031 9/24/10 CA James Stovall 910 - 263 -0535 ZONING HAS TO GO OUT BEFORE C.O. CAN BE ISSUED. N -TART CONTINUED ONTO NEXT PAGE PREPARED 9/30/10, 14:02:21 INSPECTION TICKET PAGE 7 Harnett Cauntyli INSPECTOR: IVR DATE 10 /01 /10 ADDRESS . : 96 CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R431 05 10/01/10 T TII FOUR TRADE FINAL >2500 VRU #: 001988856 POI k 1 4- R431 04 10 /01 /10 VC FOUR TRADE FINAL >2500 VRU #: 001987569 9/30/10 CA Site Contact James Stovall 910 - 263 -0535 T /S: 09/30/2010 01:40 PM VBROWN INSP CA BECAUSE FLOOD ZONING INSP NOT DONE YET. COMMENTS AND NOTES PREPARED 10/04/10, 13:59:35 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 10/05/10 1 ADDRESS . : 96C CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 03/17/2010 11:43 AM VBROWN - - -- CAROLINA LAKES #68 C PH1, CRYSTAL POINT. 27W, LEFT ON BUFFALO LAKES RD, LEFT INTO GUARD ENT, RIGHT ON CAROLINA WAY, 1ST LEFT ONTO CROWN POINT, RIGHT ONTO CRYSTAL POINT. T /S: 04/01/2010 02:34 PM NTART WILL NEED ZONING INSPECTION BEFORE JOB Is FINALLED * * * * * * * * * * * * * * * * * * * ** * * ** ** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** STRUCTURE: 000 000 76X65.25 4BDR 3.5BATH W GAR,DECK,CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS .00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/15/10 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001910249 4/15/10 CA Mike Etowski 910 - 303 -4828 T /S: 04/15/2010 08:52 AM VBROWN CUSTOMER CALLED AND WAS WANTING TO RESCHD INSP BUT COULD NOT. SCOTT SAID HE SPOKE WITH INSP. INSP HAD NOT CA INSP. I CA INSP AND RESCHD FOR 4/16/10 B101 02 4/16/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001910637 4/16/10 AP T /S: 04/15/2010 08:54 AM VBROWN T /S: 04/16/2010 11:49 AM NTART B101 03 4/20/10 MR R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001912021 4/20/10 AP T /S: 04/16/2010 11:50 AM NTART T /S: 04/20/2010 12:26 PM MREARIC B103 01 4/26/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001915503 4/26/10 DA Mike Etowski 303 -4828 T /S: 04/26/2010 01:03 PM MREARIC pier missing under kitchen pass- through window area ok to continue A814 01 5/04/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001919968 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART 96 CRYSTAL PT LOT 68C SANFORD 27332 T /S: 05/04/2010 08:40 AM TWARD B103 02 5/04/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001919943 5/04/10 AP T /S: 05/03/2010 11:43 AM NTART TSP IS READY * * * * * * * * * * * * * * * * * * * * * * * * * ** T /S: 05/04/2010 12:35 PM MREARIC 8105 01 5/04/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001919950 5/04/10 AP T /S: 05/03/2010 11:44 AM NTART T /S: 05/04/2010 12:36 PM MREARIC R427 01 6/22/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001943638 CONTINUED ONTO NEXT PAGE PREPARED 10/04/10, 13:59:35 INSPECTION TICKET PAGE 14 Harnett County INSPECTOR: IVR DATE 10/05/10 A ADDRESS . : 96R CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER . . : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6/22/10 DA James Stovall 910 - 263 -0535 T /S: 06/22/2010 02:03 PM MREARIC 1. vent termination is not high enough for pitch 2. tempered windows needed beside double door to porch 3, leak at clean -oouot under master tub 4. truss H -2 needs straps on both ends 5. joist under dtryer has been over - notched 6. ok to side but not insulate R427 02 6/29/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001947282 6/29/10 DP Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 T /S: 06/29/2010 01:08 PM MREARIC 1. the piers you installed under the notched joist under the dryer are not per code, no footer, no parging or mortar 2. according to the manuf. installation guide installation requires the lowest outlet point to be 5' above the roof when installed in a 12/12 roof R431 01 7/01/10 TI FOUR TRADE FINAL >2500 VRU #: 001948405 6/30/10 CA Mike Etowski 910 - 303 -4828 James Stovall 910 - 263 -0535 R427 03 7/01/10 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001949304 7/02/10 AP T /S: 07/01/2010 03:51 PM NTART T /S: 07/02/2010 08:14 AM NTART R431 02 7/01/10 MR FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001948637 7/01/10 CA T /S: 06/30/2010 02:30 PM JBROCK T /S: 07/01/2010 12:11 PM MREARIC this should be a rough T /S: 07/01/2010 03:51 PM NTART I129 01 7/12/10 TI R *INSULATION INSPECTION VRU #: 001952191 7/09/10 CA James Stovall 910- 263 -0535 I129 02 7/13/10 MR R *INSULATION INSPECTION VRU #: 001952787 7/13/10 - DA James Stovall 910 - 263 -0535 T /S: 07/13/2010 01 :36 PM MREARIC provide me with information on the insulation, what kind, how thick, etc. I129 03 7/16/10 MR R *INSULATION INSPECTION VRU #: 001954858 7/16/10 AP Insulation Specs were in job box for previous inspection on 07 -13 -10 James Stovall Site contact 910 - 263 -0535 T /S: 09/30/2010 01:52 PM NTART R431 03 9/27/10 TI FOUR TRADE FINAL >2500 VRU #: 001987031 9/24/10 CA James Stovall 910 - 263 -0535 ZONING HAS TO GO OUT BEFORE C.O. CAN BE ISSUED. N -TART CONTINUED ONTO NEXT PAGE PREPARED 10/04/10, 13:59:35 INSPECTION TICKET PAGE 15 Harnett,County INSPECTOR: IVR DATE 10 /05 /10 ADDRESS . : 96. CRYSTAL POINT SUBDIV: CAROLINA LAKES TENANT, NBR: NEEDS ZONING INSPECTION CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864 -0247 OWNER : DYER JODI PHONE : PARCEL . . : 03- 9585 -03- -0068- - - APPL NUMBER: 10- 50023990 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R431 05 10 /01 /10 FOUR TRADE FINAL >2500 VRU #: 001988856 10 /01 /10 DA 1. All bath /dryer ducts must vent to outside. 2. Unable to open access doors. 3. Need lockout for water heater breaker. T /S: 10/01/2010 10:49 AM DETAYLOR R431 04 10/01/10 VC FOUR TRADE FINAL >2500 VRU #: 001987569 9/30/10 CA Site Contact James Stovall 910- 263 -0535 T /S: 09/30/2010 01:40 PM VBROWN INSP CA BECAUSE FLOOD ZONING INSP NOT DONE YET. R431 06 10/05/10 TI FOUR TRADE FINAL >2500 VRU #: 001989391 � 0 - 51O Ap - nlR James Stovall 910- 236 -0535 COMMENTS AND NOTES .rz . , . - i • ' .7-1i,:i • • :.: '4 ' ' '% . , • . t hi ..F. County of Harnett • ..... , Building Inspections Department ' - ' • ... I , !- ' '''''. . • -.., ../Planning Services - . . , Certificate of Ccimpliance: Occupancy._2S,_ Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the „ . various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: TC-3 ;Permit Numbers .0 Name: 0 ye-Jr< ...,, Building:0 ." 0 Electrical: t 1 Address: 9 cr n-. Insulation: t 1 Plumbing: I , Mechanical: t , MFG Home: _ Date: /0 _ 5- /0 Building Official: ar .........._ •• , . .4 4. . .■ , •+, • s• • • 4. ., , . .1, „ 1. .,.. s .. e s . • i i., . • e. .