Loading...
INSPECTIONS PREPARED 10/07/09, 13:58:31 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 10/08/09 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING" • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 /0 •5. .9 '1P_ 11_4. COMMENTS AND NOTES PREPARED 10/20/09, 14:06:05 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 10/21/09 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING'' • NEW SEPTIC WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP /7 T /S: 10/08/2009 09:14 AM MREARIC B101 02 10/21/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001838943 16 2, .4 4-r-11;12 COMMENTS AND NOTES ` 7`Cr - 5 T QuU.c04+ kqp i i PREPARED 10/21/09, 10:05:59 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 10/21/09 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09:14 AM MREARIC B101 02 10/21/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001838943 10/21/09 CA T /S: 10/21/2009 10:05 AM NTART B103 01 10/21/09 TI R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 T /S: 10/21/2009 10:05 AM NTART COMMENTS AND NOTES nor uo GUSU 14 Jorll 001 J1J- JJJ -VJl1 r raa G � -C 1 - _t! ! G'' r • • � • 3 tit C te• r 1 ` 466 Stencil Road Angier, NC 27501 (919) 639-2073 (919) 639 -8841 Fax March 9, 2010 Harnett County Central Permitting Re: Application for Residential Building and Trades Permit 09- 50021752 Stencil Builders, Inc. releases all permits for Lot 189 Patton's Point, 120 Jumpmaster Dr. to Bradley Built, Inc. pectiv y submitted, Fr ie L. Stencil S cil Builders, Inc. / I a \ /J` PREPARED 3/30/10, 13:58:19 INSPECTION TICKET PAGE 6 Harnett Couuty -. INSPECTOR: IVR DATE 3/31/10 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2RATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09:14 AM MREARIC B103 01 10/21/09 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 10/21/09 AP T /S: 10/21/2009 10:05 AM NTART T /S: 10/21/2009 10:06 AM NTART A814 01 3/31/10 TI ADDRESS CONFIRMATION VRU #: 001902782 T /S: 03/30/2010 01:46 PM BBLEVINS B105 01 3/31/10 TI ,�I R *OPEN FLOOR VRU #: 001902816 2 I3 J ` • /O pA-&4 . COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 03 -31 -10 PERMIT 3 09- 50021752 ADDRESS: 120 jumpmaster. VIOLATIONS: 1. Header (or something) is needed under cantilevered floor joists over foundation opening Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 4/21/10, 14:02:28 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 4/22/10 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09:14 AM MREARIC B103 01 10/21/09 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 10/21/09 AP T /S: 10/21/2009 10:05 AM NTART T /S: 10/21/2009 10:06 AM NTART B105 01 3/31/10 MR R *OPEN FLOOR VRU #: 001902816 3/31/10 DA T /S: 03/31/2010 01:19 PM MREARIC header needed under cantilevered joist over access hole A814 01 3/31/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001902782 4/01/10 AP T /S: 03/30/2010 01:46 PM BBLEVINS 120 JUMPMASTER DR LOT 189 BROADWAY 27505 T /S: 04/01/2010 11:30 AM TWARD R425 01 4/22/10 TI FOUR TRADE ROUGH IN VRU #: 001913852 X 2 2 1. AF, AUK_ COMMENTS AND NOTES GPO 5f4i u w +c be �e.wpete PREPARED 4/27/10, 13:59:07 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 4/28/10 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09:14 AM MREARIC B103 01 10/21/09 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 10/21/09 AP T /S: 10/21/2009 10:05 AM NTART T /S: 10/21/2009 10:06 AM NTART 3105 01 3/31/10 MR R *OPEN FLOOR VRU #: 001902816 3/31/10 DA T /S: 03/31/2010 01:19 PM MREARIC header needed under cantilevered joist over access hole A814 01 3/31/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001902782 4/01/10 AP T /S: 03/30/2010 01:46 PM BBLEVINS 120 JUMPMASTER DR LOT 189 BROADWAY 27505 T /S: 04/01/2010 11:30 AM TWARD R425 01 4/22/10 41 , FOUR TRADE ROUGH IN VRU #: 001913852 4/22/10 T /S: 04/22/2010 11:31 AM MREARIC stair window to be tempered per R308.4.10 I129 01 4/28/10 TI R *INSULATION INSPECTION VRU #: 001917144 4'28-16 COMMENTS AND NOTES k) tettf 1n �zC/( 4 30 u s F i o c n [ 3 � rxr;rru<nu S/23/10, 13:58:00 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 8/24/10 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH . 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597= - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS / COMMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09:14 AM MREARIC 3103 01 10/21/09 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 10/21/09 AP T /S: 10/21/2009 10 :05 AM NTART T /S: 10/21/2009 10:06 AM NTART 3105 01 3/31/10 MR R *OPEN FLOOR VRU #: 001902816 3/31/10 DA T /S: 03/31/2010 01:19 PM MREARIC header needed under cantilevered joist over access hole A814 01 3/31/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001902782 4/01/10 AP T /S: 03/30/2010 01:46 PM BBLEVINS 120 JUMPMASTER DR LOT 189 BROADWAY 27505 T /S: 04/01/2010 11:30 AM TWARD R425 01 4/22/10 MR FOUR TRADE ROUGH IN VRU #: 001913852 4/22/10 AE T /S: 04/22/2010 11:31 AM MREARIC stair window to be tempered per R308.4.10 I129 01 4/28/10 MR R *INSULATION INSPECTION VRU #: 001917144 4/28/10 AP T /S: 04/28/2010 12:22 PM MREARIC still no tempered window in stairway Bonus room ovewr garage has the floor insulated H824 01 5/26/10 OT ENVIR. OPERATIONS PERMIT TIME: 08:00 VRU #: 001933571 5/26/10 AP T /S: 05/27/2010 10:22 AM SSTEWART T /S: 05/27/2010 10:23 AM SSTEWART I129 02 8/24/10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001973809 8-2.9.16 A(J -)01._ T /S: 08/23/2010 12:04 PM JBROCK FINSIH BONU ROOM AREA R225 01 8/24/10 TI TWO TRADE ROUGH IN TIME: 17:00 VRU #: 001973791 e- 2q -to AP - T /S: 08/23/2010 12:04 PM JBROCK FINSIH BONUS ROOM AREA COMMENTS AND NOTES PREPARED 9/22/10, 13:58:43 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 9/23/10 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09 :14 AM MREARIC B103 01 10/21/09 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 10/21/09 AP T /S: 10/21/2009 10:05 AM NTART T /S: 10/21/2009 10:06 AM NTART B105 01 3/31/10 MR R *OPEN FLOOR VRU #: 001902816 3/31/10 DA T /S: 03/31/2010 01:19 PM MREARIC header needed under cantilevered joist over access hole A814 01 3/31/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001902782 4/01/10 AP T /5: 03/30/2010 01:46 PM BBLEVINS /120 JUMPMASTER DR LOT 189 BROADWAY 27505 T /S: 04/01/2010 11:30 AM TWARD R425 01 4/22/10 MR FOUR TRADE ROUGH IN VRU #: 001913852 4/22/10 AE T /S: 04/22/2010 11:31 AM MREARIC stair window to be tempered per R308.4.10 I129 01 4/28/10 MR R *INSULATION INSPECTION VRU #: 001917144 4/28/10 AP T /S: 04/28/2010 12:22 PM MREARIC still no tempered window in stairway onus room ovewr garage has the floor insulated H824 01 5/26/10 OT /ENVIR. OPERATIONS PERMIT TIME: 08:00 VRU #: 001933571 5/26/10 AP T /S: 05/27/2010 10:22 AM SSTEWART T /S: 05/27/2010 10:23 AM SSTEWART 1129 02 8/24/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001973809 8/24/10 AP T /S: 08/23/2010 12:04 PM JBROCK FINSIH BONU ROOM AREA T /S: 08/24/2010 12:54 PM MREARIC R225 01 8/24/10 MR TWO TRADE ROUGH IN TIME: 17:00 VRU #: 001973791 8/24/10 AP T /S: 08/23/2010 12:04 PM JBROCK FINSIH BONUS ROOM AREA T /S: 08/24/2010 12:54 PM MREARIC R429 01 94231110 T„� 4 FOUR TRADE FINAL VRU #: 001985784 ZZ l COMMENTS AND NOTES PREPARED 9/28/10, 14:08:12 INSPECTION TICKET PAGE 2 Harnett Y8'untf INSPECTOR: IVR DATE 9/29/10 ADDRESS . : 120 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073 OWNER . . : STANCIL BUILDERS INC PHONE : PARCEL . . : 03 -9597- - -0225- -68- APPL NUMBER: 09- 50021752 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 120 JUMPMASTER DRIVE PATTONS POINT SUB DIV #189. 27W, LEFT ON DOCS RD, RIGHT MICRO TOWER RD, SUB DIV ON RIGHT. T /S: 03/17/2009 03:47 PM VBROWN - - -- STRUCTURE: 000 000 401E60 3BDR 2BATH SFD, GAR, DECK, CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 10/08/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001832832 10/08/09 AP T /S: 10/08/2009 09:14 AM MREARIC B103 01 10/21/09 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001839919 10/21/09 AP T /S: 10/21/2009 10:05 AM NTART T /S: 10/21/2009 10:06 AM NTART B105 01 3/31/10 MR R *OPEN FLOOR VRU #: 001902816 3/31/10 DA T /S: 03/31/2010 01:19 PM MREARIC header needed under cantilevered joist over access hole A814 01 3/31/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001902782 4/01/10 AP T /S: 03/30/2010 01:46 PM BBLEVINS N/120 JUMPMASTER DR LOT 189 BROADWAY 27505 T /S: 04/01/2010 11:30 AM TWARD R425 01 4/22/10 MR FOUR TRADE ROUGH IN VRU #: 001913852 4/22/10 AE T /S: 04/22/2010 11:31 AM MREARIC stair window to be tempered per R308.4.10 I129 01 4/28/10 MR R *INSULATION INSPECTION VRU #: 001917144 4/28/10 AP T /S: 04/28/2010 12:22 PM MREARIC still no tempered window in stairway Bonus room ovewr garage has the floor insulated H824 01 5/26/10 OT "Ni ENVIR. OPERATIONS PERMIT TIME: 08:00 VRU #: 001933571 5/26/10 AP T /S: 05/27/2010 10:22 AM SSTEWART T /S: 05/27/2010 10:23 AM SSTEWART I129 02 8/24/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001973809 8/24/10 AP T /S: 08/23/2010 12:04 PM JBROCK FINSIH BONU ROOM AREA T /S: 08/24/2010 12:54 PM MREARIC R225 01 8/24/10 MR TWO TRADE ROUGH IN TIME: 17:00 VRU #: 001973791 8/24/10 AP T /S: 08/23/2010 12:04 PM JBROCK FINSIH BONUS ROOM AREA T /S: 08/24/2010 12:54 PM MREARIC R429 01 9/23/10 5 FOUR TRADE FINAL VRU #: 001985784 9/23/10 DA Need 6'8" headroom at stairs T /S: 09/23/2010 09:34 AM KSLATTUM R429 02 9/29/10 TI o FOUR TRADE FINAL VRU #: 001987835 Q zq /o1� COMMENTS AND NOTES in iw vr-...„awsWSaSww...cr....„...,, . . ..... "a_osaptf✓ailti`wpai3'ou�a'` ,+'�'''£k:'i'.'.R?=tit'+Gfir.tw tS7)7a''A?s*"';!Hk ", * ww,Fo te,, y!'°,:f.yir Pa m1„,,,,lregrd , rtasittststittastat County of Harnett Building Inspections Department . , Planning Services Certificate of Compliance: Occupancy: x P 4 Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett ( County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: p. Use Classification: 1?•3 Permit Numbers Name: 13 r roil )v y 13 t o IT Building: 09- SnC Zr75_7. — 4 Electrical: I t •-, e,. Address: 1 Insulation: t I I Z c t r+' Q ' i m p Vu scho r Plumbing: I r Mechanical: t 1 MFG Home: Date: 9 .. Zq _ 0 Building Official: •-ri 24 A dp . ‘447 ( 741 1 TE -1 '11 741 :1 71 11 77477 1 477 '17 ' 1 L' It7 7V7717