Loading...
IPACHTE#11ly—a� --3810 % Harnett County Department of Public Health 28805 Improvement Permit A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: &L • I N1 X ,044�.� tC- JZZA� /ZZ ISSUED TOr/&,dalll V'7M- a ,.,a 134;6enrc. SUBDIVISION LOT # NEW I REPAIR ❑ 4EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: 1"7a4 Proposed Wastewater System ype: 1;-%.-2,, Projected Daily Flow: JDo GPD 4 ya l LaydaeS Number of bedrooms: Number of Occupants: max Basement ❑Yes 9 No Pump Required: ❑Yes ❑ No 9111ay be required based an final location and elevations of facilities Type of Water Supply: ❑ Community d Public ❑ Well Distance from well feet Permit valid for. P/Five years Permit conditions: ❑ No expiration Authorized State Agent:-,' , >L_��I� amt GT ! Date: 4 — '5--- 1 b SEE ATTACHED SITE SKETCH The issuance of this permitth/ Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate goveming bodies in mewing their requirements. This site is subject to revoation d the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization Reauired for Building Permit The construction and installation requirements of Rules .1958, .1957, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met Systems shall be installed in accordance with the attached system layout ISSUED TO: l PROPERTY LOCATION: 50 W8 644 F- - 4,6 SUBDIVISION LOT # Facility Type: 15 13 4 New Expansion El Repair Basement? 1-1YesNo Basemel Fixtures? ❑ Yes E�% Type of Wastewater System** Z5"/otU�uv��F� (See note below, if applicable ❑) Os'dU I %tr9rz,— (Repair) Installation Requirements/Conditions Number of trenches Z Septic Tank Size —/B10-6 gallons Exact length of each trench feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of: L 4 inches (Trench bottoms shall be level to +/•1/4" in all directions) Pump Requirements: (t. TDM vs. GPM Conditions: (Initial) Wastewater Flow: /Oy GPD Trench Spacing: �— Feet on Center Soil Cover. S— inches (Maximum soil cover shall not exceed 36" above the trench bottom) Aggregate Depth: WATER LINES (INCLUDING IRRIGATION) MUST BE IDFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. inches below pipe Z inches above pipe / Z inches total **If applicable: / undeatand the system type specified ii different hom the type speaTled on the application. / accept the tpenficationi of this peimit. Owner/Legal Representative Signature: Date: This Construction Authorization is subject to revocation if the site plan, plat or the intended use changes. The Construction Authorization shall not he transferred when there is a change in ownership of the site. This construction Authorization IS subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit 5[C MIAMI.! NIC SRC II.n /—,. Authorized State Agr.��r��---5 = ���/1,�,%La-.-C�r' Date: cl- S - 14 �, Construction Authorization Expiration Date: 4 - f-- z/ HTE# Ile- SS_38/V Permit # Z8o OS� Harnett County Department of Public Health Site Sketch PROPERTY LO(ATON:,F2Z1Y/ GI�It/7d1�F i7zu�.�.YL1� ISSUED TO: SUBDIVISION LOT # 1 _ Authorized State en�: f Date: 5,z )yia o4Kjz�z6a �fvbg ZD Department of Environment, Health and Natural Resources Division of Environmental Health On -Site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: V�`�"""� Address: .� Date Evaluated: 3-8-16 Proposed Facility: �^'"`�sh' t Design Flow (.1949): Location of Site:,.,� Property Recorded: Water Supply: U Public❑ Individual ❑ Well Evaluation Method: ❑-ager Boring ❑ Pit ❑ Cut Type of Wastewater: Sewage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: ❑ Spring ❑ Mixed ❑ Other P R O F I L E # .1940 Landscape Position/ Slope % Horizon Depth (In.) SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS Profile Class & LTAR .1941 Structure/ Texture .1941 Consistence mineralogy .1942 Soil Wetness/ Color .1943 Soil Depth IN. .1956 Sapro Class .1944 Restr Horiz 3 L,336 0- 30 3L (woe n so � xL "_ " 7� Y Description Initial Repair System Other Factors (.1946): System Site Classification (.1948): Available Space (.1945) Evaluated B System Type(s) Others Present: Site LTAR Y