IPACHTE# IS 537653 Harnett County Department of Public Health 28756 Improvement Permit A building permit cannot be issued with only an provement Permit (y ISSUED T0: M vV� PROPERTY LOCATION: t) PZtZt � 0cL(� VJJ s ct-\ear-.` t ra '% ss40 SUBDIVISION LOT # NEW REPAIR ❑ EVfANSION ❑ Type of Structure: Meav �c•.E \Y LI A-5 �Z Proposed Wastewater System Type: '1.5"/0 Projected Daily Flow: 360 GPD Number of bedrooms: 3 Number of Occupants: max Basement ❑Yes No Site Improvements required prior to Construction Authorization Issuance: Pump Required: ❑Yes No ❑ May be required based on final location and elevations of facilities Type of Water Supply: El Community Public ❑ Well Distance from well X00 feet Permit valid for. IX Five years Permit conditions: ❑ No expiration Authorized State Agent: :! h5 Date:3 u 16 SEE ATTACHED SITE SKETCH The issuance of this permit by the Health Department in no way guarantees the issuan Cher permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvem"FiN,111211 shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met Systems shall be installed in accordance with the attached system layout ISSUED T0: In a CU-) CSL PROPERTY LOCATION: C'yPWG5 GA Va0g RD (�(a SUBDIVISION Facility Type: \ eP1 )AocnC. �I4 �� New ❑ Expansion ❑ Repair Basement? ❑ Yes 'X No Basement Fixtures? 11 Yes %� No Type of Wastewater System** 9-S—/o SV,9 U G� P v S 754 6M (Initial) (See note below, if applicable ❑) ) �� �S °,c ,- C— • s (Repair) Installation Requirements/Conditions Number of trenches a Septic Tank Size T o act gallons Exact length of each trench feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of: 1$ -aZ� inches (Trench bottoms shall be level to +/-1/4" in all directions) Pump Requirements: ft. TDM vs. GPM Conditions: LOT # Wastewater Flow: 34 6 GPD Trench Spacing: 9 Feet on Center Soil Cover: inches (Maximum soil cover shall not exceed 36" above the trench bottom) Aggregate Depth: WATER LINES (INCLUDING IRRIGATION) MUST BE ]OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. inches below pipe inches above pipe inches total **If applicable: / understand the spsem type specified it different from the type specified of the application. / accept the specifications of this permit This Construction Authonz&, construction Authorization is Authorized State Agent: r the intended use changes The construction Authorization shall not be tmnshr, Laws and Rules for Sewage Treatment and Disposal and to the conditions of this T%SS Date: Cons ction Authorization Expiration Date: _ Date: a change in ownership o1 the site. This SEE ATTACHED SITE SKETCH HTE# 15-5'376S3 Harnett County Permit # Department of Public Health Site Sketch PROPERTY LOCATON Cyp26ss C�' v2C.11 '(..C) ISSUED TO: Y�1_, U AG t.- nc:1—��"C- SUBDIVISION Authorized State Agent: n(Ia5 `aLrvt?t 5otx� Date: 3 2 � T. LOT # Department of Environment, Health and Natural Resources Division of Environmental Health On -Site, Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: Address: Date Evaluated: Proposed Facility: Design Flow (.1949): Location of Site: Property Recorded: Water Supply: Public❑ Individual El Well �r�, Evaluation Method: �] Au aBoKng E] Pit ❑ Cut Type of Wastewater. ` 14 Sewage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: ❑ Spring ❑ Mixed ❑ Other P R O F 1 L E # .1940 Landscape Position/ Slope% Horizon Depth (In.) SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS Profile Class & LTAR .1941 Structure/ Texture .1941 Consistence Mineralogy .1942 Soil Wemese/ Color .1943 Soil Depth IN. .1956 Sapro Class .1944 Restr Horiz 0 G Q� l,- Q, 3-36 Six s t 5�1'P SSs�C �c t� s 3i V 3�y Description Initial Repair System Other Factors (.1946): Systew Site Classification (.1948): Available Space (. 1945) j EvaluatedBy:O\ System Type(s) 25 l _ Others Present: Site LTAR