Loading...
INSPECTIONS PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 51 Harnett County INSPECTOR: IVR DATE 5/14/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER -. . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 87S, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECK, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 S 14/ 0 R *PLUMB UNDER SLAB VRU #: 001926021 COMMENTS AND NOTES PREPARED 5/19/10, 13:56:47 INSPECTION TICKET PAGE 44 Harnett County INSPECTOR: IVR DATE 5/20/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 87S, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECK, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 O TI R *BLDG MONOLITHIC SLAB VRU #: 001929215 If COMMENTS AND NOTES PREPARED 5/25/10, 14:03:39 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 5/26/10 'ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 875, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R*PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t -pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 TI R *ELEC TEMP SERVICE POLE VRU #: 001932476 2.61/D 49ce.bi_ COMMENTS AND NOTES N� \ $ $ H . . . 1 1) o 90 � » \ �_ e � g | b �i | Ziliiiil %� / § y> | I d )� | | ` ( ■ �� 1111 11 1111 ' |, �_ ■ -- -- - - -9 . Pa | . 11 .• � — � � - - � � ■ §§ to \ § 16.7' — , i # �| - \ ?; ■ | | ( §§ _ | � | §§ - - -- - - - --- | � � ; § | P :i§ ® & §| ® ; - , §. ;: 2 =' § va r.EZ § e e § -- -- —9 . 4,_ _ /\ | � 7 z f ) k 1! § ; - ; |) |,! ; . e E. "CENTURY o,RVE80R /w § j ¥ ■ 2 ill .. | -- § /£ � �} §f ■ . ;■ , ------------------------- ■ ,. ------- - - - -- §• ; t!§ *- - | ` t PREPARED 6/14/10, 14:00:41 INSPECTION TICKET PAGE 30 Harnett County INSPECTOR: IVR DATE 6/15/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 875, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECX, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t - pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 DT R *ELEC TEMP SERVICE POLE VRU #: 001932476 5/26/10 AP A814 01 6/14/10 TI ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 001940204 T /S: 06/11/2010 01:58 PM DJOHNSON R425 01 6/15/10 TII ,� FOUR TRADE ROUGH IN VRU #: 001940804 �c / /f //d Deilk COMMENTS AND NOTES r EPARED 6/17/10, 14:06:02 INSPECTION TICKET PAGE 35 iarnitt County INSPECTOR: IVR DATE 6/18/10 ADDRESS . : 61 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . . LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 87S, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECK, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY COUNTY PHRMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t -pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 DT R *ELEC TEMP SERVICE POLE VRU #: 001932476 5/26/10 AP A814 01 6/14/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001940204 6/16/10 AP T /S: 06/11/2010 01:58 PM DJOHNSON 81 century dr lot 214 cameron 28326 T /S: 06/16/2010 04:01 PM TWARD R425 01 6/15/10 DT FOUR TRADE ROUGH IN VRU #: 001940804 6/15/10 DP 1. Need engineered letter for truss bored for electrical above garage. 2. Stud columns under girder truss must go to slab. 3. No water in stand pipe. T /S: 06/15/2010 09:38 AM DETAYLOR R427 01 ` 6/ 8 /10 TI / FOUR TRADE ROUGH IN >2500 VRU #: 001942804 AP COMMENTS AND NOTES pr7i I39tid LT2217T80T6 32IIHSOOOM 8S :20 0102 -LT -20 1 T NEERN G C A MiTek Affiliate Trenao 818 Soundside Rd Edenton, NC 27932 Re : J01885 Cav & Cates / Lot 214 Colony / Harnett The truss drawing(s) referenced below have been prepared by Truss Engineering Co. under my direct supervision based on the parameters provided by Comtech, Inc - Fayetteville. Pages or sheets covered by this seal: E5744199 thruE5744199 My license renewal date for the state of North Carolina is December 31, 2010. North Carolina COA: C -0844 -(N CAA° O Q O F s i o 4r. - ye SEAL 030652 .n • '11111r 46k 04 4241 " June 16,2010 Lassiter, Frank The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSJ/TPI -1 Chapter 2. Engineering services provided by Truss Engineering Company. l 'd 6686'°N 1N3Wd01A3O ONV1 SS3NIAVO Wd0£ b Otel . 9t 'in(' T3JFJd LT221718016 321IHS400M, S0:£0 0502 -LT -20 „ti 301636 T1we 01 Truss m FLOOR Type - 'ay Ply Ca36Olss /Lc4214 CO1ny /11ea1/a 703744109 13 1 a+. R44m,ara woman Co1*L Ina.. P.n4e, NO 28300 7 ,2301 Act 22 2010 MI Industries, 03744109 Inc. Ned Jun to 1&30;142010 Pge1 044 TOP view NI tee • 1d9.9 REPAIR: ONE It DIAMETER HOLE CUT CLEANLY AND ACCURATELY ?HROIJON THE TOP CHORD ON THE MONT FACE. 3' OP LUMBER REMAINS UNDISTURBED AND NO PLATES OR WEBS ARE DISTURBED. 1.04 II v II 1464 II 13da 44 ISd II LM x: Iwo 11 13d II axe x• 3b P Ya ¢ 1.340 c t a 3 4 6 e 7 0 0 10 11 10 19 _ I /I // % /Ii' ?� I �...._ �.�� 0. germ ii�� I`I iii........... �i m x 10 17 1e 1e 14 13 12 3!e = loll FP = 341 = 141 = 3x10 1x 3.1 a 3410 = APPLY 2X6 X 134.0' SYP NOR WAS TO ONE SIDE OF TRUSS CENTERED ON MAASS, WITH CONSTRUCTION DUALITY ADHESIVE AND 1 ROW OP 100(3' X 0.1311NAILS SPACED 2.0' O.C. I 34444 . (X dg 141E4pe) . _.. aOeA l 08 4d4141F 4444., .. __ 4 444._ w LOADING (pH) SPACING 1.74 CSI DEFL In (bc) IMO Ltd PLATES ORW TOLL 40.80 Plates Increase 1.00 TC 0.44 Vert(LL) - 028 14 - 13 '631 480 MT10 ] 244/100 TOOL 10.0 Lumb&Inupse 1.00 SC 034 Virgil.) - 0.4014.16 »532 360 MT16 111/147 BCU. 0.0 Rap &revs bra TO Wit 032 11pa(TL) 0.00 12 MI No BCC SO COOS IRC20WR1 (Mcd03) Weight 102 FT 4 201100,1111E LUMBER BRACWO TOP CHORD 4 X 2 gyp No.t TOP CHORD Structural woad siloaVenp directly applied a 04-0 cc purling, SOT CHORD 4X28YP No,1 end vertical&. WEBS 4 X 2 SYP No.3 SOT CHORD ROM cia,9 NNW applied of 10-0-0 ea bmdng. REACTIONS OWUae) 18 (nen. 048), 124821044 (nrb, 0-14) FORCE= (Ile) - Medmum Ce321raedayMa3lman TansiOn TOP CHORD 18. 1 0.83/( 1 , 1.18.830, 12.20 -83/0, 1140.8310. 1-2 34-286W0, 34r2859/0, 4.8•306710, 04°388110, 6.7-- $eet4, 14e•28GO/0, $43.2860/0.1)-100,28013. 10 -11x410 ear CHORD 17.183441700, 16.17'.0 /3510,18.1801510,1419.0 /3807,13.14x0/3610,12.1311071700 WEBS 2- 18xI86810, 2- 17.011280, 3. 17--206341, 4- 1 1n-7000,10.12x.18890,10.13180I1293, 8.13=2001 7.134-7081 144.- 11 4B 12 ,6. 1 4..271µ1,4- 16.116/612.6 -18x- 271/41 NOTES 1) Unbalanced 6034 the Toad' have been om,I red for 01134 design. 2) All plates aro MT20 pleats unless otlwwian MOWW9Isd. 3) Preddt mechanical annsodolt (bycan) of teem to hewing plate at INN) 18. 4) TN Mae Is designed In 3033rdanao 1NO3 ire 2003 traemedaml Residential Coda sections 8802.11.1 and 8802.108 and referenced standard ANSIRPI 1. e) Rebommend 238 Wongbecka, on wigs, spaced It 104)-0 on and fastened m each tun ,mph 3-10d (0.131' X 3) nails. Bbonabadcs to be attached to wells et Me r outer ands or restrained by mgr maws. LOAD DAB&(&) Standard ,, 11 1u1Jn 14 ' ,```'•(H CARD S EAL - 030652 • �k R.LA`� i11r1,.,1,11` June 18,2010 • A I2Aw940 We0 3. 1w634 paten14'4 m4 2BLa NOna QM Item num MtStkonxxuxrawc wI 747a ra le ea W029 L t. �,`,,,, .dd b w ars/ ..011 Wet 4xnecin. la k 7:; .. L' =...` depl me.Nrle4n commits WonJndudb,Nk gcamoenxrc . I At VILE NIA I ..,: 4 C c . ..« 44,44.._:, y ... r 101 ne. r1 w!'Yer.xxw0.s..n _.. 4444__ __......... _ 4_44_4._ I 1 4444. 4444. � _ _ � �y,5.. .- }w... ........._.- 4444._ PREPARED 6 /21/10, 14:01:39 INSPECTION TICKET PAGE 24 -Harnett Coupty INSPECTOR: IVR DATE 6/22/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR CAVINESS -LAND DEVELOPMENT PHONE : (919) 481 -0503 . OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 87S, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECR, SLAB FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t -pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 DT R *ELEC TEMP SERVICE POLE VRU #: 001932476 5/26/10 AP A814 01 6/14/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001940204 6/16/10 AP T /S: 06/11/2010 01:58 PM DJOHNSON 81 century dr lot 214 cameron 28326 T /S: 06/16/2010 04:01 PM TWARD R425 01 6/15/10 DT FOUR TRADE ROUGH IN VRU #: 001940804 6/15/10 DP 1. Need engineered letter for truss bored for electrical above garage. 2. Stud columns under girder truss must go to slab. 3. No water in stand pipe. T /S: 06/15/2010 09:38 AM DETAYLOR R427 01 6/18/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001942804 6/18/10 AP I129 01 6/22/10 TI R *INSULATION INSPECTION VRU #: 001944178 G- 2z- ( a DA-CV� COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillitigton, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 06 -22 -10 PERMIT # 10- 50024215 ADDRESS: 81 century VIOLATIONS: No adequate access is provided for final inspection of blown in insulation over kitchen or upstairs front bedroom Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 6/24/10, 14:01:D8 INSPECTION TICKET PAGE 37 Harnett County INSPECTOR: IVR DATE 6/25/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 875, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECK, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP 8114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t -pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 DT R *ELEC TEMP SERVICE POLE VRU #: 001932476 5/26/10 AP A814 01 6/14/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001940204 6/16/10 AP T /S: 06/11/2010 01:58 PM DSOHNSON 81 century dr lot 214 cameron 28326 T /S: 06/16/2010 04:01 PM TWARD R425 01 6/15/10 DT FOUR TRADE ROUGH IN VRU #: 001940804 6/15/10 DP 1. Need engineered letter for truss bored for electrical above garage. 2. Stud columns under girder truss must go to slab. 3. No water in stand pipe. T /S: 06/15/2010 09:38 AM DETAYLOR R427 01 6/18/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001942804 6/18/10 AP I129 01 6/22/10 R *INSULATION INSPECTION VRU #: 001944178 6/22/10 DA T /S: 06/22/2010 12:52 PM MREARIC provide adequate access for final inspection of blown -in insulation over kitchen and over the front bedroom upstairs I129 02 6/25/10 TI R *INSULATION INSPECTION VRU #: 001945943 'IU7f4 or or COMMENTS AND NOTES PREPARED 8/26/10, 14:00:49 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 8/27/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF LEXINGTON #214. 27W TO 24/87, 87S, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECK, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t -pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 DT R *ELEC TEMP SERVICE POLE VRU #: 001932476 5/26/10 AP A814 01 6/14/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001940204 6/16/10 AP /S: 06/11/2010 01:58 PM DJOHNSON 81 century dr lot 214 • cameron 28326 T /S: 06/16/2010 04:01 PM TWARD R425 01 6/15/10 DT FOUR TRADE ROUGH IN VRU #: 001940804 6/15/10 DP 1. Need engineered letter for truss bored; for electrical above garage. 2. Stud columns under girder truss must go to slab. 3. No water in stand pipe. T /S: 06/15/2010 09:38 AM DETAYLOR R427 01 6/18/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001942804 6/18/10 AP 1129 01 6/22/10 MR R *INSULATION INSPECTION VRU #: 001944178 6/22/10 DA T /S: 06/22/2010 12:52 PM MREARIC provide adequate access for final inspection of blown -in insulation over kitchen and over the front bedroom upstairs I129 02 6/25/10 DT R *INSULATION INSPECTION VRU #: 001945943 6/25/10 AP R429 01 8/27/10 TI FOUR TRADE FINAL VRU #: 001975660 `d /7710 COMMENTS AND NOTES YKEYARED 8 /30/10, 14:17:48 INSPECTION TICKET I PAGE 13 Harnettl.County _- INSPECTOR: IVR I DATE '8/31/10 ADDRESS . : 81 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS LAND DEVELOPMENT PHONE : (919) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -10- -0282- -26- , APPL NUMBER: 10- 50024215 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/23/2010 01:02 PM VBROWN - - -- 81 CENTURY DRIVE, THE COLONY OF ' LEXINGTON #214. 27W TO 24/87, 87S, LEFT ON SAWYER RD, HEAD TO BACK OF NEW SECTION OF GATES OF LEXINGTON. STRUCTURE: 000 000 45X58 3BDR 2.5BATH SFD W GAR,DECR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 1 P309 01 5/14/10 KS R *PLUMB UNDER SLAB VRU #: 001926021 5/14/10 AP B114 01 5/20/10 DT R *BLDG MONOLITHIC SLAB VRU #: 001929215 5/20/10 AP t -pole ground rod not driven all the way into ground. T /S: 05/20/2010 09:47 AM DETAYLOR E207 01 5/26/10 DT R *ELEC TEMP SERVICE POLE VRU #: 001932476 5/26/10 AP A814 01 6/14/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001940204 6/16/10 AP T /S: 06/11/2010 01:58 PM DJOHNSON v81 century dr lot 214 cameron 28326 T /S: 06/16/2010 04:01 PM TWARD R425 01 6/15/10 DT FOUR TRADE ROUGH IN VRU #: 001940804 6/15/10 DP 1. Need engineered letter for truss bored;for electrical above garage. 2. Stud columns under girder truss must go to slab. 3. No water in stand pipe. T /S: 06/15/2010 09:38 AM DETAYLOR ' R427 01 6/18/10 DT FOUR TRADE ROUGH IN >2500 VRU #: 001942804 6/18/10 AP I129 01 6/22/10 MR R *INSULATION INSPECTION VRU #: 001944178 6/22/10 DA T /S: 06/22/2010 12:52 PM MREARIC provide adequate access for final inspection of blown -in insulation over kitchen and over the front bedroom upstairs 1129 02 6/25/10 DT R *INSULATION INSPECTION VRU #: 001945943 6/25/10 AP R429 01 8 / 27 /10 FOUR TRADE FINAL VRU #: 001975660 i i 8/27/10 DA 1. Microwave on 20amp breaker, needs 20amp receptacle 2. Missin light outside of master r T /S: 08/27/2010 09:27 AM DETAYLOR R429 02 8/31/10 TI FOUR TRADE FINAL VRU #: 001976482 8/3111 PrP D 14 COMMENTS AND NOTES .e " R'r+ i " Y'�:'f` +. , ,N a r +rr 'r -m ,€.. r c '. n”" a+�^ c t '�'RA` .a. ;, *i- b pi n� ... ry i � ::, r� � L �{'.'.. r 1 sum t �' ` ' County of Harnett Building Inspections Department ' . Planning Services r' Ce rtificate of Com liance: , < Occu an : X P P , ` Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett r 4 County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the • various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: taes l Permit Numbers Name:CO. , ncs S �a� d �t� Building: \? \ Electrical: .0" ri# Address: S I Cevr ►, r Insulation: tit/ �uw+c ro yl KR.- a /3 Plumbing: . 5 4. Mechanical: \ , MFG Home: Date: 8 /31// 0 Building OfficiaLJ /yi p. fie, os,7 7 W7„,‘ a T7 'T '3Z7