Loading...
INSPECTIONS ED 8/04/09, 14:22:02 INSPECTION TICKET PAGE 39 tt County INSPECTOR: IVR DATE 8/05/09 RESS . : 35 LAKEFOREST TRL SUBDIV: CAROLINA LAKES NTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700 WNER . . : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL ( SFD) DIRECTIONS : T /S: 07/30/2009 10:52 AM VBROWN - - -- CAROLINA LAKES SUB DIV #159 0, LAKE FOREST TRAIL. HWY 27W, LEFT ON BUFFALO LAKE RD, LEFT INTO CAROLINA LAKES SUB DIV, LEFT ON CAROLINA WAY, LEFT GOTO CLEARWATER HARBOR, RIGHT GO TO 3RD ROAD, TURN LEFT 3RD LOT ON LEFT. STRUCTURE: 000 000 46X57 3BDR 2BATH SFD WITH GAR DECK FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 8/05/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001804954 a 5,q yi p- HZ would like inspection around noon. COMMENTS AND NOTES PREPARED 8/11/09, 13:58:23 INSPECTION TICKET PAGE 27 Harnett County INSPECTOR: IVR DATE 8/12/09 ADDRESS . : 35 LAKEFOREST TRL SUBDIV: CAROLINA LAKES CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700 OWNER . . : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 07/30/2009 10:52 AM VBROWN - - -- CAROLINA LAKES SUB DIV #159 0, LAKE FOREST TRAIL. HWY 27W, LEFT ON BUFFALO LAKE RD, LEFT INTO CAROLINA LAKES SUB DIV, LEFT ON CAROLINA WAY, LEFT GOTO CLEARWATER HARBOR, RIGHT GO TO 3RD ROAD, TURN LEFT 3RD LOT ON LEFT. STRUCTURE: 000 000 46X57 3BDR 2BATH SFD WITH GAR DECK FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE . . . . . . . . .S F D SEPTIC - EXISTING' • SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 8/05/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001804954 8/05/09 AP would like inspection around noon. T /S: 08/05/2009 11:54 AM MREARIC t pole too B103 01 8/12/09 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001807281 R -1 2'Oq a COMMENTS AND NOTES PREPARED 8/17/09, 14:00:37 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 8/18/09 ADDRESS . : 35 LAKEFOREST TRL SUBDIV: CAROLINA LAKES CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700 OWNER . : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 07/30/2009 10:52 AM VBROWN - - -- CAROLINA LAKES SUB DIV #159 0, LAKE FOREST TRAIL. HWY 27W, LEFT ON BUFFALO LAKE RD, LEFT INTO CAROLINA LAKES SUB DIV, LEFT ON CAROLINA WAY, LEFT GOTO CLEARWATER HARBOR, RIGHT GO TO 3RD ROAD, TURN LEFT 3RD LOT ON LEFT. STRUCTURE: 000 000 46E57 3BDR 2BATH SFD WITH GAR DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 8/05/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001804954 8/05/09 AP would like inspection around noon. T /S: 08/05/2009 11:54 AM MREARIC t pole too B103 01 8/12/09 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001 8/12/09 AP T /S: 08/12/2009 11:14 AM MREARIC damp proofing req'd B105 01 8/18/09 TI R *OPEN FLOOR VRU #: 001810222 ,gn AYR COMMENTS AND NOTES 'PREPARED 9/16/09, 14:02:04 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 9/17/09 I ADDRESS . : 35 LAKEFOREST TRL SUBDIV: CAROLINA LAKES CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700 OWNER . . : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 07/30/2009 10:52 AM VBROWN - - -- CAROLINA LAKES SUB DIV #159 0, LAKE FOREST TRAIL. HWY 27W, LEFT ON BUFFALO LAKE RD, LEFT INTO CAROLINA LAKES SUB DIV, LEFT ON CAROLINA WAY, LEFT GOTO CLEARWATER HARBOR, RIGHT GO TO 3RD 1 ROAD, TURN LEFT 3RD LOT ON LEFT. STRUCTURE: 000 000 46X57 3BDR 2BATH SFD WITH GAR DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY - COUNTY i PERMIT: CPSF 00 CP * SFD I REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS I I B101 01 8/05/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001804954 8/05/09 AP would like inspection around noon. T /S: 08/05/2009 11:54 AM MREARIC t pole too 8103 01 8/12/09 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001807281 8/12/09 AP T /S: 08/12/2009 11:14 AM MREARIC I damp proofing req'd B105 01 8/18/09 MR R *OPEN FLOOR VRU #: 001810222 I 8/18/09 AP T /S: 08/18/2009 11:29 AM MREARIC I A814 01 9/14/09 TI ADDRESS CONFIRMATION VRU #: 001820596 R427 01 9/14/09 FOUR TRADE ROUGH IN >2500 VRU #: 001820604 9/14/09 DA T /S: 09/14/2009 12:59 PM MREARIC truss straps are not per uplift specs fireblock at fireplace r -38 will be req'd ok to side and insul I I129 01 9/16/09 R *INSULATION INSPECTION TIME: 17:00 VRU #: 001822022 9/16/09 DA T /S: 09/15/2009 11:20 AM NTART T /S: 09/16/2009 10:18 AM NTART T /S: 09/16/2009 12:16 PM MREARIC fireblock at fireplace I129 02 9/17/09 / �TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001822808 R'R'..( 317.9 T /S: 09/16/2009 10:18 AM NTART R427 02 9/17/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001822014 0 1.47..q q -(7.9 T /S: 09/15/2009 11:20 AM NTART T /S: 09/16/2009 10:18 AM NTART COMMENTS AND NOTES i V `\RED 7/28/10, 13:58:02 INSPECTION TICKET j PAGE 1 .tt County •', INSPECTOR: IVR 1 DATE 7/29/10 URESS . : 65 LAKEFOREST TRL SUBDIV: CAROLINA LAKES NTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700 OWNER . . : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 07/30/2009 10:52 AM VBROWN - - -- CAROLINA LAKES SUB DIV #159 0, LAKE FOREST TRAIL. HWY 27W, LEFT ON BUFFALO LAKE RD, LEFT INTO CAROLINA LAKES SUB DIV, LEFT ON CAROLINA WAY, LEFT GOTO CLEARWATER HARBOR, RIGHT GO TO 3RD ROAD, TURN LEFT 3RD LOT ON LEFT. I STRUCTURE: 000 000 46X57 3BDR 2BATH SFD WITH GAR DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING 4111111111° WATER SUPPLY COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 8/05/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001804954 8/05/09 AP would like inspection around noon. T /S: 08/05/2009 11:54 AM MREARIC t pole too B103 01 8/12/09 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001807281 8/12/09 AP T /S: 08/12/2009 11:14 AM MREARIC damp proofing req'd B105 01 8/18/09 MR R *OPEN FLOOR VRU #: 001810222 8/18/09 AP T /S: 08/18/2009 11:29 AM MREARIC R427 01 9/14/09 MR FOUR TRADE ROUGH IN >2500 VRU #: 001820604 9/14/09 DA T /S: 09/14/2009 12:59 PM MREARIC truss straps are not per uplift specs fireblock at fireplace r -38 will be req'd ok to side and insul A814 01 9/14/09 TW. �AHHRESS CONFIRMATION TIME: 17:00 VRU #: 001820596 9/21/09 AP 65 LAKEFOREST TRL LOT 159 0 SANFORD 27332 T /S: 09/21/2009 02:24 PM TWARD I129 01 9/16/09 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001822022 9/16/09 DA T /S: 09/15/2009 11:20 AM NTART T /S: 09/16/2009 10:18 AM NTART T /S: 09/16/2009 12:16 PM MREARIC fireblock at fireplace I129 02 9/17/09 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001822808 9/17/09 AP T /S: 09/16/2009 10:18 AM NTART T /S: 09/17/2009 11:49 AM MREARIC R427 02 9/17/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001822014 9/17/09 AP T /S: 09/15/2009 11:20 AM NTART T /S: 09/16/2009 10:18 AM NTART T /S: 09/17/2009 11:49 AM MREARIC R429 01 7/29/10 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 01960814 +� _ 7.24- )/ ama__ T /S: 07/28/2010 12:31 PM RDCONTE COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910 -893 -7525 DO NOT REMOVE DATE: 07 -29 -10 PERMIT # 09- 50022550 ADDRESS: 651akeforest Trl Violations: 1. Back steps not finished 2. Bracing per appendix M is required on back deck 3. Back deck must be self supported or be bolted per code to house 4. Handrails needed on front steps 5. Main service not complete 6. Panel neutral is not installed correctly, no tightening bolt installed on neutral in panel 7. No outlet is installed in attic Harnett County Building Department Mike Rearic cell# (910) 984- 4772 i I PREPARED 7/30/10, 14:23:37 INSPECTION TICKET PAGE 3 Harngt %'- County INSPECTOR: IVR DATE 8/02/10 ADDRESS . : 65 LAKEFOREST TRL SUBDIV: CAROLINA LAKES CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700 OWNER . . : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 07/30/2009 10:52 AM VBROWN - - -- CAROLINA LAKES SUB DIV #159 0, LAKE FOREST TRAIL. HWY 27W, LEFT ON BUFFALO LAKE RD, LEFT INTO CAROLINA LAKES SUB DIV, LEFT ON CAROLINA WAY, LEFT GOTO CLEARWATER HARBOR, RIGHT GO TO 3RD ROAD, TURN LEFT 3RD LOT ON LEFT. STRUCTURE: 000 000 46X57 3BDR 2BATH SFD WITH GAR DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE I SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSP 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 8/05/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001804954 8/05/09 AP would like inspection around noon. T /S: 08/05/2009 11:54 AM MREARIC t pole too B103 01 8/12/09 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001807281 8/12/09 AP T /S: 08/12/2009 11:14 AM MREARIC damp proofing req'd B105 01 8/18/09 MR R *OPEN FLOOR VRU #: 001810222 8/18/09 AP T /S: 08/18/2009 11:29 AM MREARIC R427 01 9/14/09 MR FOUR TRADE ROUGH IN >2500 VRU #: 001820604 9/14/09 DA T /S: 09/14/2009 12:59 PM MREARIC truss straps are not per uplift specs fireblock at fireplace r -38 will be req'd ok to side and insul A814 01 9/14/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001820596 9/21/09 AP 65 LAKEFOREST TRL LOT 159 0 SANFORD 27332 T /S: 09/21/2009 02:24 PM TWARD I129 01 9/16/09 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001822022 9/16/09 DA T/S: 09/15/2009 11:20 AM NTART T /S: 09/16/2009 10:18 AM NTART T /S: 09/16/2009 12:16 PM MREARIC 1 fireblock at fireplace I129 02 9/17/09 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001822808 9/17/09 AP T /S: 09/16/2009 10:18 AM NTART T /S: 09/17/2009 11:49 AM MREARIC R427 02 9/17/09 MR FOUR. TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001822014 9/17/09 AP T /S: 09/15/2009 11:20 AM NTART T /S: 09/16/2009 10:18 AM NTART T /S: 09/17/2009 11:49 AM MREARIC R429 01 7/29/10 MR FOUR TRADE FINAL TIME: 17:00 VRU #: 001960814 7/29/10 DP T /S: 07/28/2010 12:31 PM RDCONTE T /S: 07/29/2010 10:06 AM MREARIC CONTINUED ONTO NEXT PAGE PREPARED 7/30/10, 14:23:37 INSPECTION TICKET PAGE 4 HarnEtS. County INSPECTOR: IVR DATE 8/02/10 ADDRESS . 65 LAKEFOREST TRL SUBDIV: CAROLINA LAKES CONTRACTOR BECKER WILLIAM H PHONE : (910) 263 -2700 OWNER : BECKER WILLIAM H GLENDA F PHONE : (910) 263 -2700 PARCEL . . : 03- 9585 -15- -0159- - - APPL NUMBER: 09- 50022550 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 1. back steps not finished 2. brace deck per code 3, back deck must be self supporting or bolted to house per code 4. handrails on front steps 5, main service not complete 6. panel neutral not finished 7. no outlet in attic R429 02 7/30/10 MR FOUR TRADE FINAL VRU #: 001961663 7/30/10 CA T /S: 07/30/2010 12:00 PM MREARIC bolt deck braces separate neutral and groundd at interior panel R429 03 8 /02 /10 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 001962190 A -do A COMMENTS AND NOTES 1 -w. - - rr- ..w.....nve`:a.uWww�arw.�. - .e- a.....- • •7'.' A . ., .. i .-� .... .. a County of Harnett Building Inspections Department • Planning Services :w a- .�. «,w„ • �µ', pp •w n .e «r, !. � •..�. xuiw J,,,a't..v.w.p:+c . .E 6 ' C erttficate of Com Nance O ccu arrcy. Certificate issued pursuant to the requirements of North Carolina General Statute I53A -363 and Harnett • County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. for the following: • Use Classification: ]2- - Permit N Name: �ec ice r- Lit .1. I I a Building: 04- 5 c., 2C£Q Electrical: I 1 Address: Insulation: 1 ', 4 S L C. k� erect Tr/ . Plumbing: 1 ' ' Mechanical: 1 r ' MFG Home: ,, Date: e_ z_ i 0 Building Official: / , —A, i'rlz - n 1 ‘flETV'Ticei. ,:in 'VW" Tiff V) "re i;;We WA" VT 1