Loading...
INSPECTIONS PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 58 Harnett County INSPECTOR: IVR DATE 5/14/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK - - -- TAKE HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56X62 4BDR SLAB W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSP 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 1_ R *PLUMB UNDER SLAB VRU #: 001926369 /J Q "�" COMMENTS AND NOTES PREPARED 5/18/10, 14:12:44 INSPECTION TICKET PAGE 58 Harnett County INSPECTOR: IVR DATE 5/19/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK - - -- TAKE HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56(62 4BDR SLAB W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 JH R *PLUMB UNDER SLAB VRU #: 001926369 5/14/10 AP - -- B114 01 5/17/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001927045 5/17/10 CA M305 01 5 19/10 TI ,, R *PLUMB SEWER CONNECTION VRU #: 001929009 P307 01 5/19/10 T R *PLUMB WATER CONNECTION VRU #: 001929017 C -5 k/n COMMENTS AND NOTES PkEPARED 5/19/10, 13:56:47 INSPECTION TICKET PAGE 58 Harnett County INSPECTOR: IVR DATE 5/20/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK - - -- TAKE HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56X62 4BDR SLAB W/ GARAGE FLOOD ZONE - FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 JH R *PLUMB UNDER SLAB VRU #: 001926369 5/14/10 AP - -- B114 01 5/17/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001927045 5/17/10 CA M305 01 5/19/10 JH R *PLUMB SEWER CONNECTION VRU #: 001929009 5/19/10 AP P307 01 5/19/10 JH R *PLUMB WATER CONNECTION VRU #: 001929017 5/19/10 AP B114 02 /20/10 TI , R *BLDG MONOLITHIC SLAB VRU #: 001929686 r I COMMENTS AND NOTES REScheck Software Version 4.3.0 Compliance Certificate Project Title: Carpenter Energy Code: 2006 IECC Location: Spring Lake, North Carolina Construction Type: Single Family Conditioned Floor Area: 3041 ft2 Glazing Area Percentage: 7% Heating Degree Days: 3169 Climate Zone: 3 Construction Site: Owner /Agent: Designer /Contractor: 744 Highgrove Dr. Spring Lake, NC 28390 Permit # 10- 50024366 Compliance Passes on•UA "trade - off ` "-- ._rc Compliance: Maximum UA: 681 Your UA: 605 Maximum SHGC: 0.40 Your SHGC: 0.28 • ., . Gross Cavity Cont:.r. ' Glazing UA Assembly. „ ..Area or R -Value ,., -Value 'or Door. Perimeter U- Factor Ceiling 1: Flat Ceiling or Scissor Truss - 688 38.0 0.8 20 Ceiling 2: Cathedral Ceiling (no attic) 690 38.0 0.0 19 Wall 1: Wood Frame, 16 ".o.c. 2216 13.0 0.8 182 Wall 2: Wood Frame. 16" o.c. 825 13.0 0.8 48 Window 1: Vinyl Frame:Double Pane with Low -E 185 0.350 65 SHGC: 0.28 Door 1: Glass 18 0.350 6 SHGC: 0.28 Door 2: Solid - 42 0.500 21 Floor 1: Slab -On- Grade:Unheated 234 0.0 244 Insulation depth: 0.13' Heat Pump 1: Air Source 7.7 HSPF, 13 SEER Air Conditioner 1: Electric Central Air 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meat the 2006 IECC requirements in REScheck Version 4.3.0 and to comply with the mandatory requirements listed in the R Scheck Inspection Checklist. Name - Title Signature Date • Project Title: Carpenter Report date: 05/20/10 • Data filename: C:\Documents and SettingslBryan \Desktop \Res Check Templates \Res check Carpenter.rck Page 1 of 1 • ATC Associates of North Carolina, PC 2725 E. Millbrook Rd Suite 121 Raleigh, NC 27604 Phone: 919 -871 -0999 Fax: 919 -871 -0335 www.atcassociates.com May 19, 2010 Mr. George Aiken Savvy Homes 6030 Creedmoor Road, Suite 101 Raleigh, NC 27612 Ph: 919 781 - 8104 Fax: 919 781 - 8105 Re: Foundation Evaluation for Lot 131 Highgrove at Anderson Creek in Spring Lake, North Carolina ATC Project Number: 45.34028.0005 Dear Mr. Aiken, ATC visited the above referenced site to observe and evaluate foundation soils for Lot 131. At the time of our visit, building pad construction and footing excavation were complete. Using a '' /z inch diameter steel probe rod and Dynamic Cone Penetrometer (DCP) per ASTM STP 399, ATC tested soils at bottom of footing elevation. In addition, ATC performed hand augers and DCP testing at the four outer corners if fill was present. ATC performed DCP testing at 1 foot intervals down to satisfactory residual soils or maximum depth of 5 feet below finish pad elevation. Results, at areas and elevations tested, indicated soils have sufficient bearing capacity to support a foundation designed for a net allowable bearing capacity of 2,000 pounds per square foot (psf). Respectfully, ATC Associates of North Carolina, PC 4 93 v* : /4P � SEAL 034487 iQ RAN &EP koCb Cr 'air PS:0 e / Herbert L. Hales, II, P.E. Project Engineer PREPARED 5/27/10, 14:33:11 INSPECTION TICKET PAGE 44 Harnett County INSPECTOR: IVR DATE 5/28/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK - - -- TAKE HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56X62 4BDR SLAB W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 JH R *PLUMB UNDER SLAB VRU #: 001926369 5/14/10 AP - -- B114 01 5/17/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001927045 5/17/10 CA M305 01 5/19/10 JH R *PLUMB SEWER CONNECTION VRU #: 001929009 5/19/10 AP P307 01 5/19/10 JH R *PLUMB WATER CONNECTION VRU #: 001929017 5/19/10 AP B114 02 5/20/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001929686 5/20/10 AP T /S: 05/20/2010 03:39 PM JHALL E207 01 28/10 QTII��� R *ELEC TEMP SERVICE POLE VRU #: 001933720 COMMENTS AND NOTES PREPARED' 6/11/10, 14:20:47 INSPECTION TICKET PAGE 35 Harnett County INSPECTOR: IVR DATE 6/14/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE ®ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : - PARCEL . . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK -- HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56X62 4BDR SLAB W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 JH R *PLUMB UNDER SLAB VRU #: 001926369 5/14/10 AP - -- B114 01 5/17/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001927045 5/17/10 CA M305 01 5/19/10 JH R *PLUMB SEWER CONNECTION VRU #: 001929009 5/19/10 AP P307 01 5/19/10 GB R *PLUMB WATER CONNECTION VRU #: 001929017 5/19/10 AP B114 02 5/20/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001929686 5/20/10 AP T /S: 05/20/2010 03:39 PM JHALL E207 01 5/28/10 JH R *ELEC TEMP SERVICE POLE VRU #: 001933720 5/28/10 AP R425 01 6/14/10 TI_ FOUR TRADE ROUGH IN VRU #: 001940089 4 -r4 -/a COMMENTS AND NOTES PREPARED 7/21/10, 14:00:37 INSPECTION TICKET PAGE 21 Harnett County INSPECTOR: IVR DATE 7/22/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK - - -- TAKE HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56E62 4BDR SLAB W/ GARAGE FLOOD ZONE FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 JH R *PLUMB UNDER SLAB VRU #: 001926369 5/14/10 AP - -- 6114 01 5/17/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001927045 5/17/10 CA M305 01 5/19/10 JH R *PLUMB SEWER CONNECTION VRU #: 001929009 5/19/10 AP P307 01 5/19/10 JH R *PLUMB WATER CONNECTION VRU #: 001929017 5/19/10 AP 8114 02 5/20/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001929686 5/20/10 AP T /S: 05/20/2010 03:39 PM JHALL E207 01 5/28/10 JH R *ELEC TEMP SERVICE POLE VRU #: 001933720 5/28/10 AP R425 01 6/14/10 JH FOUR TRADE ROUGH IN VRU #: 001940089 6/15/10 AP Inspection passed on 6- 15- 1OJHALL A814 01 6/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001942184 6/21/10 AP T /S: 06/21/2010 03:30 PM TWARD 744 highgrove dr lot 131 T /S: 06/21/2010 03:30 PM TWARD I129 01 6/17/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001942382 6/17/10 AP T /S: 06/16/2010 02:16 PM NTART R431 01 7/19/10 JH FOUR TRADE FINAL >2500 VRU #: 001955988 7/19/10 CA per Andrew R431 02 22/10 a FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001957224 T /S: 07/21/2010 08:31 AM NTART COMMENTS AND NOTES PREPARED 7/26/10, 14:13:01 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 7/27/10 ADDRESS . : 744 HIGHGROVE DR SUBDIV: HIGHGROVE@ANDERSON CRK PH4 40L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . : 01- 0504 -01- -0177- -33- APPL NUMBER: 10- 50024366 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/13/2010 11:11 AM JBROCK - - -- TAKE HWY 210 SOUTH FROM LILLINGTON TURN RIGHT ONTO RAY RD S/D WILL BE YOUR LEFT TURN LEFT ONTO HIGHGROVE DR LOT 131 STRUCTURE: 000 000 56X62 4BDR SLAB W/ GARAGE FLOOD ZONE • FL00D ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 5/14/10 JH R *PLUMB UNDER SLAB VRU #: 001926369 5/14/10 AP - -- B114 01 5/17/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001927045 5/17/10 CA M305 01 5/19/10 JH R *PLUMB SEWER CONNECTION VRU #: 001929009 5/19/10 AP P307 01 5/19/10 JH R *PLUMB WATER CONNECTION VRU #: 001929017 5/19/10 AP 8114 02 5/20/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001929686 5/20/10 AP T /S: 05/20/2010 03:39 PM JHALL E207 01 5/28/10 JH R *ELEC TEMP SERVICE POLE VRU #: 001933720 5/28/10 AP R425 01 6/14/10 JH FOUR TRADE ROUGH IN VRU #: 001940089 6/15/10 AP Inspection passed on 6- 15- 10JHALL A814 01 6/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001942184 6/21/10 AP T /S: 06/21/2010 03:30 PM TWARD Si 744 highgrove dr lot 131 T /S: 06/21/2010 03:30 PM TWARD I129 01 6/17/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001942382 6/17/10 AP T /S: 06/16/2010 02:16 PM NTART R431 01 7/19/10 JH FOUR TRADE FINAL >2500 VRU #: 001955988 7/19/10 CA per Andrew R431 02 7/22/10 FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001957224 7/22/10 DA T /S: 07/21/2010 08:31 AM NTART Er8" fpm grade to untreated wood.2wrong address should be 744.ont porch columns..incomplete. ,0Insulate pull down stairs.5)24" walkway to AHU in attic. R429 01 7/23/10 JH FOUR TRADE FINAL VRU #: 001958503 7/23/10 CA per Andrew R431 03 7/27/10 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001959139 7:77—/O 4 / Y ) T /S: 07/23/2010 12:32 PM DJOHNSON T /S: 07/26/2010 11:03 AM NTART COMMENTS AND NOTES 71 a -+ :7 9a.. 777 a . v 1 '« s . x % i s r 9 .g e^✓ . jj :. :";1: it ... cti '.. f. t t (11- iii 4 (4%. 4;1)sikai,..4:4 County of Harnett _ ` Building Inspections Department , .; -- ' _ a .., Planning Services . Certificate of Compliance:. Occupancy: b. Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Hamett County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the 4 . various ordinances of the Count Harnett and the North Carolina State Building Codes. For the following: r• Use Classification: - f� Permit Numbers Name:16 6�t tes Building: ....., Electrical: M -7 � Address: / � 0, i / Insulation: C Plumbing: Mechanical: ' ^ 6 ) ) MFG Home: Date: 7 _ r ) 7 - / D Building Official: ,. 4 : " %'. 'i :•rl' • ' }:.'Siifi. y.,, ::t.:..4 :.:'. •t V 3':.