INSPECTIONS PREPARED 4/29/10, 13:58:27 INSPECTION TICKET PAGE 26
Harnett County INSPECTOR: IVR DATE 4/30/10
ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 - 41
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL .. . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON --
CHANDLERS RIDGE LOT 5
72 JACK HARRIS LANE
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 51X52 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING? - SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 4/30/10 TI k R *PLUMB UNDER SLAB VRU #: 001918731
COMMENTS AND NOTES
PREPARED 5/05/10, 14:24:39 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 5/06/10
ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON --
CHANDLERS RIDGE LOT 5
72 JACK HARRIS LANE
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 51X52 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 4.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY ' • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 4/30/10 DT R *PLUMB UNDER SLAB VRU #: 001918731
4/30/10 AP 1. House not framed in accordance with engineered plans.
2. #rd floor roughed -in, fire block top plate at side walls.
3. Engineered repair for master not completed.
4. Fasten switch box in 2nd floor hall.
5. Replace /refasten loose /torn house wrap.
Do not side or insulate.
T /S: 04/30/2010 10:20 AM DETAYLOR
B114 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001920735
g-6-16
B125 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001920727
5/05/10 CA T /S: 05/05/2010 02:24 PM NTART
COMMENTS AND NOTES
PREPARED 6/09/10, 13 :58:44 INSPECTION TICKET PAGE 26
Harnett County INSPECTOR: IVR DATE 6/10/10
ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON --
CHANDLERS RIDGE LOT 5
72 JACK HARRIS LANE
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 51152 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 4/30/10 DT R *PLUMB UNDER SLAB VRU #: 001918731
4/30/10 AP 1. House not framed in accordance with engineered plans.
2. #rd floor roughed -in, fire block top plate at side walls.
3. Engineered repair for master not completed.
4. Fasten switch box in 2nd floor hall.
5. Replace /refasten loose /torn house wrap.
Do not side or insulate.
T /S: 04/30/2010 10:20 AM DETAYLOR
B114 01 5/06/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001920735
5/06/10 AP
B125 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 0019207271
5/05/10 CA T /S: 05/05/2010 02:24 PM NTART
R425 01 6/10/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU # 001937934
6f100 igr o T /S: 06/09/2010 07:52 AM NTART
COMMENTS AND NOTES
PREPARED 6/15/10, 14:24:35 INSPECTION TICKET PAGE 26
Harnett County INSPECTOR: IVR DATE 6/16/10
ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON --
CHANDLERS RIDGE LOT 5
72 JACK HARRIS LANE
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 51E52 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 4/30/10 DT R *PLUMB UNDER SLAB VRU #: 001918731 I{
4/30/10 AP 1. House not framed in accordance with engineered plans.
2. #rd floor roughed -in, fire block top plate at side walls.
3. Engineered repair for master not completed.
4. Fasten switch box in 2nd floor hall.
5. Replace /refasten loose /torn house wrap)
Do not side or insulate.
T /S: 04/30/2010 10:20 AM DETAYLOR
B114 01 5/06/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001920735
5/06/10 AP
B125 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001920727
5/05/10 CA T /S: 05/05/2010 02:24 PM NTART
R425 01 6/10/10 • FOUR TRADE ROUGH IN TIME: 17:00 VRU #:i 001937934
6/10/10 DA T /S: 06/09/2010 07:52 AM NTART
1. A03, Ao4, A09, Al0 trusses not braced p roperly.
2. Al2 and D03 trusses not strapped properly.
3. No test on gas line.
4. Middle bedroom smoke detector not wired.
5. Fire caulk laundry room pan drain at top plate.
6. Re -caulk water lines for spare upstairs tub /shower
Okay to side, do not insulate.
T /S: 06/10/2010 11:20 AM DETAYLOR
R425 02 6/15/10 VC FOUR TRADE ROUGH IN VRU #: 001940902
6/15/10 CA T /S: 06/14/2010 03:59 PM VBROWN
TRAVIS CALLED AND CA INSP WANTED IT FOR WED
R425 03 y/16/10 TI FOUR TRADE ROUGH IN VRU #: 001941061
0 {fL(to r
COMMENTS AND NOTES
PREPARED 6/18/10, 14:00:33 INSPECTION TICKET PAGE 18
Harnett County INSPECTOR: IVR DATE 6/21/10
ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON -- ++�
CHANDLERS RIDGE LOT 5
72 JACK HARRIS LANE '
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 51X52 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 4/30/10 DT R *PLUMB UNDER SLAB VRU #: 001918731
4/30/10 AP 1. House not framed in accordance with engineered plans.
2. #rd floor roughed -in, fire block top plate at side walls.
3. Engineered repair for master not completed.
4. Fasten switch box in 2nd floor hall.
5. Replace /refasten loose /torn house wrap.
Do not side or insulate.
T /S: 04/30/2010 10:20 AM DETAYLOR
B114 01 5/06/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001920735
5/06/10 AP
B125 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001920727
5/05/10 CA T /S: 05/05/2010 02:24 PM NTART
R425 01 6/10/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001937934
6/10/10 DA T /S: 06/09/2010 07:52 AM NTART
1. A03, Ao4, A09, A10 trusses not braced properly.
2. Al2 and D03 trusses not strapped properly.
3. No test on gas line.
4. Middle bedroom smoke detector not wired.
5. Fire caulk laundry room pan drain at top plate.
6. Re -caulk water lines for spare upstairs tub /shower
Okay to side, do not insulate.
T /S: 06/10/2010 11:20 AM DETAYLOR
R425 02 6/15/10 VC FOUR TRADE ROUGH IN VRU #: 001940902
6/15/10 CA T /S: 06/14/2010 03:59 PM VBROWN
TRAVIS CALLED AND CA INSP WANTED IT FOR WED
R425 03 6/16/10 DT FOUR TRADE ROUGH IN VRU #: 001941061
6/16/10 AP
A814 01 6/18/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001942929
T /S: 06/17/2010 01:27 PM JBROCK
I129 01 6/18/10 RD R *INSULATION INSPECTION TIME: 17 :00 VRU #: 001942937
6/18/10 CA T /S: 06/17/2010 01:28 PM JBROCK
T /S: 06/18/2010 07:30 AM RDCONTE
ROLLED TO 6/21/10
I129 02 6/21/10 TI R *INSULATION' INSPECTION TIME: 17 :00 VRU #: 001943109
/
(2Ajto flf T /S: 06/18/2010 07:31 AM RDCONTE
COMMENTS AND NOTES
PREPARED 7/23/10, 14:14:51 INSPECTION TICKET PAGE 12
Hainett County INSPECTOR: IVR I DATE 7/26/10
, ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON --
CHANDLERS RIDGE LOT 5 i
72 JACK HARRIS LANE
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 51E52 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - SEWER WATER SUPPLY 1 • COUNTY
I
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
I
P309 01 4/30/10 DT R *PLUMB UNDER SLAB VRU #: 001918731
4/30/10 AP 1. House not framed in accordance with engineered plans.
2. #rd floor roughed -in, fire block top plate at side walls.
3. Engineered repair for master not completed.
4. Fasten switch box in 2nd floor hall.
5. Replace /refasten loose /torn house wrap
Do not side or insulate.
T /S: 04/30/2010 10:20 AM DETAYLOR
B114 01 5/06/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001920735
5/06/10 AP
B125 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001920727
5/05/10 CA T /S: 05/05/2010 02:24 PM NTART
R425 01 6/10/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU # 001937934
6/10/10 DA T /S: 06/09/2010 07:52 AM NTART
1. A03, Ao4, A09, A10 trusses not bracedlproperly.
2. Al2 and D03 trusses not strapped properly.
3. No test on gas line.
4. Middle bedroom smoke detector not wired.
5. Fire caulk laundry room pan drain at top plate.
6. Re -caulk water lines for spare upstairs tub /shower
Okay to side, do not insulate.
T /S: 06/10/2010 11:20 AM DETAYLOR
R425 02 6/15/10 VC FOUR TRADE ROUGH IN VRU #: 001940902
6/15/10 CA T /S: 06/14/2010 03:59 PM VBROWN
TRAVIS CALLED AND CA INSP WANTED IT FOR WED
R425 03 6/16/10 DT FOUR TRADE ROUGH IN VRU #: 001941061
6/16/10 AP
A814 01 6/18/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRUI #: 001942929
6/21/10 AP T /S: 06/17/2010 01:27 PM JBROCK
72 jack harris In lot 5 '
T /S: 06/21/2010 03:32 PM TWARD
I129 01 6/18/10 RD R *INSULATION INSPECTION TIME: 17:00 VRU #: 001942937
6/18/10 CA T /S: 06/17/2010 01:28 PM JBROCK
T /S: 06/18/2010 07:30 AM RDCONTE
ROLLED TO 6/21/10
I129 02 6/21/10 DT R *INSULATION INSPECTION TIME: 17:00 VRU #: 001943109
CONTINUED ONTO NEXT PAGE
.PREPARED 7/23/10, 14:14:51 INSPECTION TICKET PAGE 13
HaynettCounty INSPECTOR: IVR DATE 7/26/10
ADDRESS . : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
6/21/10 AP T /S: 06/18/2010 07:31 AM RDCONTE
R431 01 7/26/10 T FOUR TRADE FINAL >2500 VRU #: 001958563!
:1 4 '- VOICE MESSAGE LEFT
COMMENTS AND NOTES
PREPARED 7/26/10, 14:13:01 INSPECTION TICKET PAGE 12
Harnett County INSPECTOR: IVR DATE 7/27/10
3 1'
ADDRESS . : -72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 02/26/2010 11:18 AM DJOHNSON --
CHANDLERS RIDGE LOT 5
72 JACK HARRIS LANE
210 SOUTH RIGHT ON OVERHILLS RD THEN
RIGHT INTO CHANDLERS RIDGE
STRUCTURE: 000 000 53152 4BR SLAB, PATIO GARAGE OPT SUNROOM
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
P309 01 4/30/10 DT R *PLUMB UNDER SLAB VRU #: 001918731
4/30/10 AP 1. House not framed in accordance with engineered plans.
2. #rd floor roughed -in, fire block top plate at side walls.
3. Engineered repair for master not completed.
4. Fasten switch box in 2nd floor hall.
5. Replace /refasten loose /torn house wrap.
Do not side or insulate.
T /S: 04/30/2010 10:20 AM DETAYLOR
B114 01 5/06/10 JH R *BLDG MONOLITHIC SLAB VRU #: 001920735
5/06/10 AP
B125 01 5/06/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001920727
5/05/10 CA T /S: 05/05/2010 02:24 PM NTART
R425 01 6/10/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001937934
6/10/10 DA T /S: 06/09/2010 07:52 AM NTART
1. A03, Ao4, A09, Al0 trusses not bracediproperly.
2. Al2 and D03 trusses not strapped properly.
3. No test on gas line.
4. Middle bedroom smoke detector not wired.
5. Fire caulk laundry room pan drain at top plate.
6. Re -caulk water lines for spare upstairs tub /shower
Okay to side, do not insulate.
T /S: 06/10/2010 11:20 AM DETAYLOR
R425 02 6/15/10 VC FOUR TRADE ROUGH IN VRU #: 001940902
6/15/10 CA T /S: 06/14/2010 03:59 PM VBROWN
TRAVIS CALLED AND CA INSP WANTED IT FOR WED
R425 03 6/16/10 DT FOUR TRADE ROUGH IN VRU #: 001941061
6/16/10 AP
A814 01 6/18/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001942929
6/21/10 AP T /S: 06/17/2010 01:27 PM JBROCK
V72 jack harris In lot 5
T /S: 06/21/2010 03:32 PM TWARD
I129 01 6/18/10 RD R *INSULATION INSPECTION TIME: 17:00 VRU #: 001942937
6/18/10 CA T /S: 06/17/2010 01:28 PM JBROCK
T /S: 06/18/2010 07:30 AM RDCONTE
ROLLED TO 6/21/10
I129 02 6/21/10 DT R *INSULATION INSPECTION TIME: 17:00 VRU #: 001943109
CONTINUED ONTO NEXT PAGE
PREPARED 7/26/10, 14:13:01 INSPECTION TICKET PAGE 13
Harnett County INSPECTOR: IVR DATE 7/27/10
ADDRESS : 72 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS
CONTRACTOR : AMERICAN HOMESMITH LLC PHONE : (919) 422 -4128
OWNER . . : AMERICAN HOMESMITH LLC #5 PHONE : (919) 600 -8988
PARCEL . . : 01 -0514- - -0002- -05-
APPL NUMBER: 10- 50023856 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
6/21/10 AP T /S: 06/18/2010 07:31 AM RDCONTE
R431 01 7/26/10 JH FOUR TRADE FINAL >2500 VRU #: 001958563
7/26/10 DA VOICE MESSAGE LEFT
1)Missing lights on front ® garage doors.2)No insulation in
/ attic.3)ground rod need to be 8' in ground & 6' min apart.
R431 02 7/27/10 TI - -K FOUR TRADE FINAL >2500 VRU #: 001959626
7
COMMENTS AND NOTES
y Y l - • , , : ii . :Asti A A AL Ai Att io i h t.„ ..‘d r adistA , A , s , N , n 2,7 '
le st)
- County of Harnett
4 .
Building Inspections. Department
Planning Services
Certificate' ®ff C®mnjplliance: (Occupancy:
. Certificate issued pursuant to the requirements of North Carolina General Statute 153A -3 and Harnett
County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the `
1/41 various ordinances of the Coun of Harnett and the North Carolina State Building Codes. Foi the following:'
Use Classification: F P ermit Numbers o
Name: (2,, ,; 6, , Lnn� r 5nti fd (..1 Building: y"'
/( Electrical:
Address: 22 A 4 * a,-i f t i Insulation: C'
Plumbing:
Mechanical: "•1
MFG Home: I b kk, ,.
Date: 7_ _ 70 Building Official: .fi-5 --c" /J ' s
4
' terRraliegfele74\1‘7M T)7 MM Mg 71, 1
,.