Loading...
IPAC RRHTE# ��-=339s'G,2� Harnett County Department of Public Health 28403 Improvement Permit A building permit cannot be issued with only an Improvement Permit ISSUED TO V�L�t ��•tJ"�iruc %e, PROPERTY LOCATION: Iec'/ d. SUBDIVISION f fc, +Qv1 Bcic� a LOT # NEW R REPAIR ❑ , EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: J -Y 6 U Proposed Wastewater System Type: P, Projected Daily Flow: 3(Q 0 GPD Number of bedrooms: 3 Number of Occupants: C max Basement ❑Yess0 No Pump Required: QYes ❑ No Ma ❑ be required based on final location and elevations of facilities Type of Water Supply: El Community Public ❑ Well Distance from well feet Permit valid for: R1Five years Permit conditions: ❑ No expiration Authorized State Agent:: -4 /'Kz' o'-- , yJ Date: 6 /.Z z— If 2u l.r SEE ATTACHED SITE SKETCH The issuance of this permit by tge Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: �.31`2V/LA A.l0 PROPERTY LOCATION: �oc`r,eCd SUBDIVISION T� 44 i gee c1cc LOT # V51Facility Type: J'c ZNew El Expansion El Repair Basement? ❑ Yes ❑ No Basement Fixtures? ❑ Yes ❑ No Type of Wastewater System- P,, . 4-- �!'Yo �edvc� w JI11A r- (Initial) Wastewater Flow: J(Q c GPD (See note below, if applicable ❑) at'"?� ,,�e�.sL�.orn �f-�4'v�- (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size /00 o gallons Pump Tank Size /c),00 gallons Pump Requirements: ft. TDH vs. Conditions: Exact length of each trench 300 feet Trenches shall be installed on contour at a Maximum Trench Depth of: Id- ,� inches (Trench bottoms shall be level to +/-1/4" in all directions) GPM 0,4 ''Q4 Co /tlly P161 Trench Spacing: �_ Feet on Center Soil Cover: inches (Maximum soil cover shall not exceed 36" above the trench bottom) inches below pipe ate Depth: inches above pipe —9( inches total WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. **If applicable: /understand the system type specified is different from the type specified on the application. !accept the specifications of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is subject to revocation if the site plan, plat, or the intended use changes. The Construction Authorization shall not be transferred when there is a rhnnae in nwnar6in of rho city Thi, Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State Agent- A �c' Date: r- ,-2/",/J— �C Authorization Expiration Date: LL2 -a 2 o Southeastern Soil & Environmental Associates, Inc. P.O. Box 9321 Fayetteville, NC 28311 PhcrielFax (910) 822-4540 Email mike (a) south easte msoil. com April 20, 2015 Harnett County Health Dept. 307 Cornelius Harnett Blvd. Lillington, NC 27546 Re. Hydraulic conductivity (Ksat) analysis for subsurface waste disposal system (repair area), Trotters Ridge Subdivision, Lot 44, Darley Ct., Harnett County, North Carolina To whom it may concern, An evaluation of soil and hydraulic conductivity (Ksat) has been conducted on the aforementioned property. The purpose of the investigation was to determine soil absorption rates for a proposed repair septic system to serve a 3 bedroom single family residence. All ratings and determinations were made in accordance with "Laws and Rules for Sanitary Sewage Collection, Treatment, and Disposal, 15A NCAC 18A .1900". Soils in the proposed repair area consist of 12 to 16 inches of a very friable loamy sand underlain by a firm sandy clay loam to 24 inches. Below 24 inches is a firm sandy clay loam BC and C horizons [no evidence of soil wetness within 36 inches of the soil surface. Any mottling was considered relic of a mineral deposition]. One compact constant head permearneter (CCHP) measurement was made to determine a Ksat rate at a depth of 36 inches (C horizon). The measured Ksat rate was were 0.17 cm/hr. This equates to 1.00 gpd/sq. ft. Using 30% of the lowest Ksat measured equates to 0.30 gpd/sq. 411. (acceptable allowance if using pretreatment). The proposed repair system (ultra shallow conventional installed at grade with 6 inches of soil cover) is based on a 0.30 gpd/sq. ft, conventional application rate which is considerably less than the measured rate. The Ksat measured support a higher application rate if needed, however, for the purposes of this proposal we will use a more conservative figure. SOIL/SITE EVALUATION - SOIL PHYSICAL ANALYSIS - LAND USE/SUBDIVISION PLANNING * WETLANDS GROUNDWATER DRA"NAGE.'MOUNDIN(, - SURFACES -SUBSURFACE WASTE TRF --AD M,ENT SYS'$ EMS, EVALUAfION &DESIGN SOUTHEASTERN SOIL & ENVIRONMENTAL ASSOC., INC, PROPOSED SUBSURFACE WASTE DISPOSAL SYSTEM DETAIL SHEET SUBDIVISION i-L,0CE INITIAL SYSTEM DISTRIBUTION BENCHMARK NO. BEDROOMS 33 LINE FLAG COLOR ELEVATION LOT REPAIR vi DISTRIBUTION C LOCATION X<- � Y PROPOSED LTAR 0, LENGTH {FT} BY i-, TYPICAL PROFILE 4..7- �,a I DATE Yr /14A)( -rWA-T- -?*' 1kc-ed7- 114(4-1 6AA-4-t- XlWr-e Southeastern Soil & Environmental Associates, Inc. P.O. Box 9321 Fayetteville, NC 28311 Phone'Fax (910) 822-4540 Email YT,,.ek�C,�southeasterns,,,)il.corTi ep.-l'-saip (-.A y4p 0 SaL/SITE EVALUATION - SOIL PHYSICAL ANALYSIS - LAND USE/SUBDIVISION PLANNING - WETLANDS GROUNDWATER DRAINAGE/MOUNDING - SURFAC E/SUBSU R FACE WASTE THEATMENT SYSTEM9, EVALUATION & DLSIGN