Loading...
IPAC RHTE # J��sR Harnett County Department of Public Health 28189 Improvement Permit A building permit cannot be issued with only an Improvement Permit �' `` PROPERTY LOCATION: �o z Lo2ca Qon,o ISSUED TO: CR� UT'(NG.%�s SvQ 1`tQMGs ING SUBDIVISION oo;�S LOT # NEWX REPAIR I� EPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: S� (G" Proposed Wastewater System Type: ' .S iC) V—C-�b Nv e.t �JYS n Projected Daily Flow: GPD Number of bedrooms: Number of Occupants: max Basement [--]Yes No Pump Required: []Yes �<No ❑ May be required based on final location and elevations of facilities Type of Water Supply: ❑ Community Public ❑ Well Distance from well i®U feet Permit valid for.'Five years Permit conditions: ❑ o expiration Authorized State Agent:: ���\\�`�C?�\ � Date: IS SEE ATTACHED SITE SKETCH The issuance of this permit by the Health Department in no way guarantees the issuances her permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement it shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: clil(n"�'LIL-PN-tp PROPERTY LOCATION: ��t �–ra s P\D / SUBDIVISION \A00,05 LOT # 175 Facility Type: 1��� New ❑ Expansion ❑ Repair Basement? ❑ Yes X No Basement Fixtures? ❑ Yes --�o Type of Wastewater System** 2)5'/o Q<:` )o .cy G'v5'S' Cts (Initial) Wastewater Flow: 34 0 GPD (See note below, if applicable ❑) \ ��cic�czi<�(Repair Installation Requirements/Conditions Number of trenches 1 Septic Tank Size 1000 gallons Exact length of each trench X00 feet Trench Spacing: c— Feet on Center Pump Tank Size gallons Trenches shall be installed on contour at a Soil Cover: G inches Maximum Trench Depth of. ��), inches (Maximum soil cover shall not exceed (Trench bottoms shall be level to +/-1/4" 36" above the trench bottom) in all directions) Pump Requirements: ft. TDH vs. GPM inches below pipe Aggregate Depth: inches above pipe Conditions: D � ' 62-s t�'X z --L- � vQ41>.� cW f DO Go= y > inches total WATER LINES (INCLUDING IRRIGATION) MUST BE 1OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. **If applicable: / understand the system type specified is different from the type specified on the application. / accept the specifications of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is su ' ct to revocation if the site plan, plat, or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownershia of the site. This Construction Authorization is subject to comt� ions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State Agent: Date: 3) n o ction Authorization Expiration Date: HTE # )I Li - 5 - 3'-T (-- � Permit # al ) � ) Harnett County Department of Public Health Site Sketch PROPERTY LOCATON: Zo ISSUED TO: �r4c, SUBDIVISION e5�L-��2 'YAC 00S LOT # Authorized State Agent 1�00"��. Date: A 1-0 0 Southeastern Soil & Environmental Associates, Inc. P.O. Box 9321 Fayetteville, NC 28311 Phone/Fax (910) 822-4540 Email ii�iket,ysoutheasternsoil.c�)m February 4, 2015 Harnett County Health Dept. 307 Cornelius Harnett Blvd. Lillington, NC 27546 Re: Hydraulic conductivity (Ksat) analysis for pretreatment/drip irrigation subsurface waste disposal system (repair area), Ballard Woods Subdivision, Lot 145, Gwendolyn Way, Harnett County, North Carolina To whom it may concerti, An evaluation of soil and hydraulic conductivity (Ksat) has been conducted on the aforementioned property. The purpose of the investigation was to determine soil absorption rates for a proposed pretreatment/drip irrigation repair septic system to serve a 3 bedroom single family residence. All ratings and determinations were made in accordance with "Laws and Rules for Sanitary Sewage Collection, Treatment, and Disposal, 15A NCAC 18A. 1900". Original soils in the proposed repair area were graded/cut (approximately 6 inches based on trees left in the area). The remaining soil profile consist of 0 to 6 inches of a friable loamy sand underlain by a firm sticky and plastic sandy clay loam extending to 18 to 22 inches. Below this is a firm sandy clay loam and/or sandy loam BC horizon with massive structure. This horizon extends to approximately 30 inches. Below 30 inches is a firm to very firm mixed mottled sandy clay loam to sandy clay C horizon that extends to at least 48 inches. This layer also contained lenses and pockets of sandy loam. Two compact constant head perineameter (CCHP) measurements were made to determine a Ksat rate at depths of 26 and 36 inches (BC and C horizons). Measured Ksat rates were 0.169 and 0.133 cmfl-ff. The lowest measured rate equates to 0.78 gpd/sq. ft. Using 10% of the lowest Ksat measured (C horizon) equates to 0.078 gpd/sq. ft. (typical for domestic disposal without pretreatment). Using pretreatment typically allows application rates to be increased up to 100 percent (or 0.156 gpd/sq. ft.). The proposed repair system (drip irri,,gation with pretreatment) is based on a 0.10 gpd/sq. ft. (drip rate; equates to 0.2 gpd/sq. ft. conventional rate) application rate which is considerably less than the measured rate. Based on our measurements, this rate and should allow for sufficient drainage from the proposed repair system. SOIL. ;ITE EVALUATION - SOIL PHYSIC A!- ANALYSIS 4 LAW USE'S",13CIVISION PLANNING - WETLANDS GROUNDWATER DRAINAGE. -1VIOUNDING - SU7iFACf7"'-,,UESURFACE WASTE TF,1LATMENT SYSTEPMS, EVA'-UATION & DESIGN' The system sizing is as follows: 360 gpd (a` 0.10 gpd/sq. -ft. = 3600 s+ft 3600 sq.ft /2) = 1800 linear feet of drip tine spaced on —2 foot centers. Area available for drip field �, +/- 10,000 sqft, It is imperative that no additional grading, rutting, de. occur In the area of the proposed drip field (see map). I trust this is the information required at this time. As with any evaluation/desigm, this report does not guarantee that a septic system will function for any specific le ngth of time. Please call if you 1-tave any questions. Sincerely, f Mike Eaker President g I S, re" C,% SOUTHEASTERN SOIL & ENVIRONMENTAL ASSOC,, INC, PROPOSED SUBSURFACE WASTE DISPOSAL SYSTEM DETAIL SHEET SUBDIVISION 6ALLA" Wc>opj LOT INITIAL SYSTEM Peppw& REPAIR DISTRIBUTION 5E -PA -'- BENCHMARK NO. BEDROOMS LINE FLAG COLOR ELEVATION Im DISTRIBUTION LOCATION 11- C PROPOSED LTAR 013 LENGTH (FT) 97j S -7a 43 "70 BY Aq 64�e- TYPICAL PROFILE 0--. GS slFr�.& -Y<- N 0 -r F- L- "fj SEs '? / 4 9), 1 e t4AJeA pA41;�16,,Cj { m / cA, 1 - DATE c> !% . I Z_± or. A) 0 "PtTO�VA--- 4!-PAroiNe &j1L*%,oj (To ) /490 rtt�L_ &�o Alls4a- -TO 54;80 LOA--rei-q-, *4,j 0--r- E g %�jk,F 5 IPA fbSFO S-f-fTic- I v k IT( Aw fys es 1 A Im v v 'M li L., p L PERphppq no q IL 1 c I lot 10 e , I LU. 'ti'"" THE OAKLAND W!",,,TM N PORCH ME BALLA!,R1.1 W( jillpl- fAaLxgEale- A PJP (rift' t �t-