Loading...
FM REVIEW , -' -, Harnett C O U N T Y A. j♦ _ L5A IV`,) Emergency Seriion Deportment www.harnett.org 41.0 Plan Review, Inspection and Permit Fees Application Number 14-50034808 $ 75.00 ❑ DRB Major Sub Division Prelim Site Plans $150.00 ❑ Explosive Material (90 Days) $ 75.00 ❑ Explosive Materials (72 Hours) $ 50.00 ❑ Fireworks Public Display $ 50.00 ❑ Final Inspection $ 35.00 + $2.00 per device 0 Fire Alarm Testing $ 35.00 + $2.00 per nozzle ❑ Fixed Fire Suppression $ 25.00 ❑ Insecticide Fog/Fumigation $ 50.00 ❑ Pipe Test/UST/AGST $ 50.00 ❑ Plans up to 5000 sq ft $100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $250.00 ❑ Plans 25,001 sq ft and over $ 35.00 + 2.00 per Head ❑ Sprinkler Certification Test $ 35.00 ❑ Standpipe Testing $ 25.00 ❑ Special Assembly $ 25.00 ❑ Temporary Kiosks/Displays $ 25.00 ❑ Tents/Canopies/Air Supported $ 50.00 ❑ Tank Installation (charge for each tank) $ 50.00 ❑ Tank Removal (charge for each tank) Total Devices/Heads 203 Total Cost $441.00 Code Enforcement Official Buddy Walters Date 11/04/2014 Harnett --" n COUNTY r"!, Emergency Services Department rrFi ;\r:o! www.harnett.org 1005 Edwards Brothers Drive Lillington,NC 27546 Mailing Address: November 4,2014 Pd Box 370 Lillington,NC 27546 Paul Lamm ph:910-893-7580 Envirocon, Inc. fax:910-893-5025 4343 Saint Mary's Street Wilson,NC. 27895 Re: Coats Erwin Middle School 2833 NC Hwy 55 East Dunn, NC. 28334 Application Number 14-50034808 Mr. Lamm, Thank you for submitting the fire alarm plans for fire alarm system replacement at Coats Erwin Middle School. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. Please review the following project notes. If there are any questions please do not hesitate to contact this office. • Project notes o Systems and their components shall be listed and approved for the purpose for which they are installed. o Upon completion of the installation of the fire alarm system, alarm notification appliances and circuits, alarm-initiating devices and circuits, supervisory-signal initiating devices and circuits, signaling line circuits, and primary and secondary power supplies shall be tested in accordance with NFPA 72 o 100 %testing of devices o A record of completion in accordance with NFPA 72 verifying that the system has been installed in accordance with the approved plans and specifications shall be provided o Please contact the Fire Marshal's Office to schedule final acceptance test. 910-893-0741 1 strong roots• new growth Y Thank you again for submitting fire alarm plans. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions,please do not hesitate to call this office. Again, thank you and we look forward to working with you during the construction period! Sincerely, 447- y Buddy Walters Chief Deputy Fire Marshal www.harnen.org