DOCUMENTS Harnett
C O U N T Y' A e M) Emergency S.rracrs D+partmnnt
4 '•. wwwliarn.tt.ar9
Plan Review, Inspection and Permit Fees
Application Number 14-50034824
$ 75.00 ❑ DRB Major Sub Division Prelim Site Plans
$150.00 ❑ Explosive Material (90 Days)
$ 75.00 ❑ Explosive Materials (72 Hours)
$ 50.00 ❑ Fireworks Public Display
$ 50.00 ❑ Final Inspection
$ 35.00 + $2.00 per device ❑ Fire Alarm Testing
$ 35.00 + $2.00 per nozzle ❑ Fixed Fire Suppression
$ 25.00 ❑ Insecticide Fog/Fumigation
$ 50.00 ❑ Pipe Test/UST/AGST
$ 50.00 ❑ Plans up to 5000 sq ft
$100.00 ❑ Plans 5001 sq ft to 10,000 sq ft
$150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft
$250.00 ❑ Plans 25,001 sq ft and over
$ 35.00 + 2.00 per Head ❑ Sprinkler Certification Test
$ 35.00 ❑ Standpipe Testing
$ 25.00 ❑ Special Assembly
$ 25.00 ❑ Temporary Kiosks/Displays
$ 25.00 ❑ Tents/Canopies/Air Supported
$ 50.00 ❑ Tank Installation (charge for each tank)
$ 50.00 ® Tank Removal (charge for each tank)
Total Devices/Heads 3
Total Cost $150.00
Code Enforcement Official Buddy Walters Date 10/28/2014
Harnett
C O U N T Y Emergency Services Department
�(� NORTH CAROLINA * •it
www.harnett.org
1005 Edwards Brothers Drive
Lillington,NC 27546
October 28, 2014 Mailing Address:
PO Box 370
Lillington, NC 27546
Mr. Tony Disher
Evo Corporation ph:910-893-7580
fax:910-893-5025
1703 Vargrave Street
Winston Salem,NC. 27107
Re: UGST Removal(Short Stop Food Mart)
3235 Ray Road
Spring Lake,NC.28390
Application Number 14-50034824
Mr. Disher,
Thank you for contacting our office for the tank removals. The request has been
carefully reviewed by a qualified code enforcement official to examine for full
compliance with the North Carolina Fire Prevention Code and all other fire protection
regulatory documents. There are some items that will need to be adhered to in the
process for the removals. These items are outlined and described below.
Removal of Tanks:
• Guidance
o The removal of the tanks shall follow the applicable requirements in
NFPA 30, API 2015,NFPA 226,and North Carolina Fire Prevention
Code.
• Procedures
o Combustible liquids shall be removed from the tank and connected piping.
o Piping at tank openings that is not to be used further shall be disconnected.
o Piping shall be removed from the ground(if applicable).
o Tank openings shall be capped or plugged, leaving a 1/8 to '/4 inch gap for
pressure equalization.
o Tanks shall be purged of vapor and inerted prior to removal.
strong roots • new growth
• Closure Report
o A closure report shall be submitted to the Fire Marshal's Office after the
removal of the tanks. The closure report shall detail any possible
contamination of the property resulting from the tanks and the appropriate
response. The destination of the removed tanks must also be noted.
'Tanks to be Removed (2) 6000 Callon, (1) 4000 Gallon
General Notes
• Contact our office to witness the removal of the tanks and the tests associated
with the tanks and piping attached to tanks. A Fire Inspector must be onsite to
witness test and removal of tanks.
Thank you again for submitting the request for the tank removals. Please review this
letter and adhere to any notes and alterations that were made in addition to the original
request. These remarks are for the request that was submitted and its original intent.
These remarks do not apply if the original intent changes or what was submitted on the
above date changes. If you have any questions,please do not hesitate to call this office.
Sincerely
J .4r
Buddy Walters
Chief Deputy Fire Marshal
www.harnett.org
HCEMS
Office of the Fire Marshal
P.O. Box 370
Lillington, N.C. 27546
(910)-893-7580
Permit Certificate
Business Name: SHORT STOP ANDERSON CREEK
Address: 3235 RAY RD
Spring Lake, NC 28390
OFFC 910-497-3914
Phone:
The following permit has been issued: Permit No. 0140068
Type: 036 Under Ground Tank Removal
Issued Date: 10/28/2014
Effective Date: 10/28/2014
Expiration Date:
This permit certificate has been issued for [ ] construction/ [ ] operational purposes located
at the above business location.This permit has been issued and will be enforced in accordance
with section io5 of the N.C. State Fire Prevention Code. Please contact our office for any further
questions regarding this permit.
idek 14 14 Ats /6-7(4 Al
Inspector: Rudolph Hough Walters Date
10/28/2014 Page 1