INSPECTIONS PREPARED 2/17/10, 14:16:57 INSPECTION TICKET PAGE 27
Harnett County INSPECTOR: IVR DATE 2/18/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
NO permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMES 2BDR /SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 2000000.00 PROPOSED USE • TOWNHOME
SEPTIC - EXISTING') - SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP • SPA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
3101 01 18
2/18/10 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
ate V COMMENTS AND NOTES
PREPARED 3/08/10, 13:58:54 INSPECTION TICKET PAGE 45
Harnett County INSPECTOR: IVR DATE 3/09/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMES 2BDR /SLAB
FLOOD ZONE FLOOD ZONE X
# BEDROOMS • 2000000.00 PROPOSED USE • TOWNHOME
SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
B111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 01 /10 TI,'v� R *PLUMB UNDER SLAB VRU #: 001892025
l i / / S U `e / • 4 �S Request for Tuesday morning inspection.
Thank you.
COMMENTS AND NOTES
PREPARED 3/09/10, 13:59:23 INSPECTION TICKET PAGE 24
Harnett County INSPECTOR: IVR DATE 3/10/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMRS 2BDR /SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS • 2000000.00 PROPOSED USE TOWNHOME
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
B111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 TI R *PLUMB UNDER SLAB VRU #: 001892025
Request for Tuesday morning inspection.
Thank you.
B111 02 3/10 10 TI R *BLDG SLAB INSP VRU #: 001893015
- 10 AO_ PM inspection.
COMMENTS AND NOTES
PREPARED 4/07/10, 13:59:47 INSPECTION TICKET PAGE 26
Harnett County INSPECTOR: IVR DATE 4/08/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMES 2BDR /SLAB
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 2000000.00 PROPOSED USE - TOWNHOME
SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
B111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 BS R *PLUMB UNDER SLAB VRU #: 001892025
3/09/10 AP Request for Tuesday morning inspection.
Thank you.
T /S: March 09, 2010 02:09 PM BSUTTON
B111 02 3/10/10 BS R *BLDG SLAB INSP VRU #: 001893015
3/11/10 AP Request PM inspection.
Need a copy of slab pretreat field report in box. Slab must
be treated before pour
R125 01 3/12/10 TI ONE TRADE ROUGH IN VRU #: 001893882
3/11/10 CA Slab plumbing inspection.
T /S: 03/11/2010 04:47 PM NTART
R125 02 4/08/10 TI { ONE TRADE ROUGH IN VRU #: 001906064
8' �"t'1 Separate sheathing inspection. (All 8 Units)
COMMENTS AND NOTES
PREPARED 4/20/10, 13:59:12 INSPECTION TICKET PAGE 25
Harnett County INSPECTOR: IVR DATE 4/21/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMES 2BDR /SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 2000000.00 PROPOSED USE • TOWNHOME
SEPTIC - EXISTING? SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
B111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 BS R *PLUMB UNDER SLAB VRU #: 001892025
3/09/10 AP Request for Tuesday morning inspection.
Thank you.
T /S: March 09, 2010 02:09 PM BSUTTON
B111 02 3/10/10 BS R *BLDG SLAB INSP VRU #: 001893015
3/11/10 AP Request PM inspection.
Need a copy of slab pretreat field report in box. Slab must
be treated before pour
R125 01 3/12/10 TI ONE TRADE ROUGH IN VRU #:.001893882
3/11/10 CA Slab plumbing inspection.
T /S: 03/11/2010 04:47 PM NTART
R125 02 4/08/10 KS ONE TRADE ROUGH IN VRU #: 001906064
4/08/10 AP Separate sheathing inspection. (All 8 Units)
R425 01 4/21/10 Ja FOUR TRADE ROUGH IN VRU #: 001911593
�/ /D s /Jdf�Yj Framing, Electrical, Mechancial and Plumbing Rough -ins.
COMMENTS AND NOTES
PREPARED 4/26/10, 13:59:49 INSPECTION TICKET PAGE 40
Harnett County's INSPECTOR: IVR DATE 4/27/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMES 2BDR /SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS • 2000000.00 PROPOSED USE • TOWNHOME
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP • SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
13111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 BS R *PLUMB UNDER SLAB VRU #: 001892025
3/09/10 AP Request for Tuesday morning inspection.
Thank you.
T /S: March 09, 2010 02:09 PM BSUTTON
B111 02 3/10/10 BS R *BLDG SLAB INSP VRU #: 001893015
3/11/10 AP Request PM inspection.
Need a copy of slab pretreat field report in box. Slab must
be treated before pour
R125 01 3/12/10 TI ONE TRADE ROUGH IN VRU #: 001893882
3/11/10 CA Slab plumbing inspection.
T /S: 03/11/2010 04:47 PM NTART
R125 02 4/08/10 KS ONE TRADE ROUGH IN VRU #: 001906064
4/08/10 AP Separate sheathing inspection. (All 8 Units)
R425 01 4/21/10 B FOUR TRADE ROUGH IN VRU #: 001911593
4/21/10 A Framing, Electrical, Mechancial and Plumbing Rough -ins.
����/J 1. Need a structural nail plate at center load wall where 3
inch drain is drilled through top plate. also need one at
top plate where front porch beam intersects. 2. Need wedge
CONTINUED ONTO NEXT PAGE
PREPARED 4/26/10, 13:59:49 INSPECTION TICKET PAGE 41
Harnett County INSPECTOR: IVR DATE 4/27/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
anchors in bottom plate in various units within 1 foot of
joints. Ok to insulate
R425 02 4/27/10 TI FOUR TRADE ROUGH IN VRU #: 001914563
Insulation inspection; framing re- inspection; plumbing
re- inspection
COMMENTS AND NOTES
PREPARED 5/05/10, 13:58:24 INSPECTION TICKET PAGE 26
Harnett Co. ty ! INSPECTOR: IVR DATE 5/06/10
ADDRESS ..: 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20X30 TOWNHOMES 2BDR /SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS • 2000000.00 PROPOSED USE • TOWNHOME
SEPTIC - EXISTING? SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
B111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 BS R *PLUMB UNDER SLAB VRU #: 001892025
3/09/10 AP Request for Tuesday morning inspection.
Thank you.
T /S: March 09, 2010 02:09 PM BSUTTON
B111 02 3/10/10 BS R *BLDG SLAB INSP VRU #: 001893015
3/11/10 AP Request PM inspection.
Need a copy of slab pretreat field report in box. Slab must
be treated before pour
R125 01 3/12/10 TI ONE TRADE ROUGH IN VRU #: 001893882
3/11/10 CA Slab plumbing inspection.
T /S: 03/11/2010 04:47 PM NTART
R125 02 4/08/10 KS ONE TRADE ROUGH IN VRU #: 001906064
4/08/10 AP Separate sheathing inspection. (All 8 Units)
R425 01 4/21/10 BS FOUR TRADE ROUGH IN VRU #: 001911593
4/21/10 DA Framing, Electrical, Mechancial and Plumbing Rough -ins.
1. Need a structural nail plate at center load wall where 3
inch drain is drilled through top plate. also need one at
top plate where front porch beam intersects. 2. Need wedge
CONTINUED ONTO NEXT PAGE
PREPARED 5/05/10, 13:58:24 INSPECTION TICKET PAGE 27
Harnett County -j INSPECTOR: IVR DATE 5/06/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
anchors in bottom plate in various units within 1 foot of
joints. Ok to insulate
R425 02 4/27/10 BS FOUR TRADE ROUGH IN VRU #: 001914563
4/27/10 AP Insulation inspection; framing re- inspection; plumbing
re- inspection
T /S: April 27, 2010 11:36 AM BSUTTON
R225 01 5/06/10 T TWO TRADE ROUGH IN VRU #: 001921295
Water and Sewer Line Inspection.
COMMENTS AND NOTES
1
PREPARED 7/09/10, 15:16:01 INSPECTION TICKET PAGE 19
Harnett County INSPECTOR: IVR DATE 7/12/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK - - --
421 SOUTH TO BUIES.�,CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
APPL NOTES : BPMN 12/30/09 T /S: 12/30/2009 08:36 AM JBROCK
No permits can be issued on this job
until we get a new recorded map cutting
the lots out for the townhomes. It
should also have the homes plotted for
a site plan. Application numbers issued
at this time only for plan review. Make
sure there is a site plan in the file
and a new 2010 map. The tracking step
for planning will also need to be
approved.
STRUCTURE: 000 000 20730 TOWNHO•ES 2BDR /SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 2000000.00 PROPOSED USE TOWNHOME
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
8111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
8103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 BS R *PLUMB UNDER SLAB VRU #: 001892025
3/09/10 AP Request for Tuesday morning inspection.
Thank you.
T /S: March 09, 2010 02:09 PM BSUTTON
8111 02 3/10/10 BS R *BLDG SLAB INSP VRU #: 001893015
3/11/10 AP Request PM inspection.
Need a copy of slab pretreat field report in box. Slab must
be treated before pour
R125 01 3/12/10 TI ONE TRADE ROUGH IN VRU #: 001893882
3/11/10 CA Slab plumbing inspection.
T /S: 03/11/2010 04:47 PM NTART
R125 02 4/08/10 KS ONE TRADE ROUGH IN VRU #: 001906064
4/08/10 AP Separate sheathing inspection. (All 8 Units)
R425 01 4/21/10 SS FOUR TRADE ROUGH IN VRU #: 001911593
4/21/10 DA Framing, Electrical, Mechancial and Plumbing Rough -ins.
1. Need a structural nail plate at center load wall where 3
inch drain is drilled through top plate. also need one at
top plate where front porch beam intersects. 2. Need wedge
CONTINUED ONTO NEXT PAGE
PREPARED 7/09/10, 15:16:01 INSPECTION TICKET PAGE 20
Harnett County INSPECTOR: IVR DATE 7/12/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
REQUESTED INSP .DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
anchors in bottom plate in various units within 1 foot of
joints. Ok to insulate
R425 02 4/27/10 BS FOUR TRADE ROUGH IN VRU #: 001914563
4/27/10 AP Insulation inspection; framing re- inspection; plumbing
re- inspection
T /S: April 27, 2010 11:36 AM BSUTTON
R225 01 5/06/10 KS TWO TRADE ROUGH IN VRU #: 001921295
5/06/10 AP Water and Sewer Line Inspection..
R431 01 6/24/10 TI FOUR TRADE FINAL >2500 VRU #: 001945294
6/23/10 CA Final
T /S: 06/23/2010 02:16 PM NTART
CANCELLED FINAL INSPECTION NO ADDRESS CONFIRMATION.
A814 01 6/25/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001945922
6/25/10 AP T /S: 06/25/2010 02:24 PM TWARD
103 WOLF CREEK LN UNIT 22
LILLINGTON 27546
T /S: 06/25/2010 02:25 PM TWARD
R429 01 7/12/10 TI �! FOUR TRADE FINAL VRU #: 001950823
1.12 IS4& All trade final.
COMMENTS AND NOTES
i >'\ ,,c,,,„,,,,,,,•,„,„ ,,s4,,,s4,..tti.14,,t/s,..,,, \ye,4,/,•/,
....... _s,,,,,,.„,..s. ,,...._ ,,,..„,_<
:/-/
County of Harnett
4 . 1 B ullding Inspections Department '
Planning services Y r
,/ Certificate of Compliance: Occupancy: X
Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett
)) County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the -�
various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: f
Use Classification: SF Townhome Permit Numbers V
Name: Stafford Custom Homes Building: 09- 50023501
Electrical: 09- 50023501
0-.4. Address: 103 Wolf Creek Lane Insulation: 09- 50023501
Lillington NC 27546 Plumbing: 09- 50023501
Mechanical: 50023501
✓ MFG Home: xxxxxxx
4i Date: 07 -14 -10 Building Official: BSutton
ii
, , , , ■lier ■ 44.
PREPARED 7/14/10, 9:38:41 INSPECTION TICKET PAGE 9
Harnet INSPECTOR: Sutton Brad DATE 7/14/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
DIRECTIONS : T /S: 12/30/2009 08:35 AM JBROCK
421 SOUTH TO BUIES CREEK LESLIE
CAMPBELL TO KIVET RIGHT ON OLD CHURCH
UNIT 22
PERMIT: CPFA 00 CP * SFA
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
8101 01 2/18/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001884436
2/18/10 AP T /S: February 18, 2010 12:04 PM BSUTTON
8111 01 3/01/10 DJ R *BLDG SLAB INSP VRU #: 001888007
2/26/10 CA Foundation Inspection
T /S: 02/26/2010 03:24 PM DJOHNSON
B103 01 3/01/10 BS R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001888650
3/01/10 AP T /S: 02/26/2010 03:27 PM DJOHNSON
T /S: March 01, 2010 10:37 AM BSUTTON
P309 01 3/09/10 BS R *PLUMB UNDER SLAB VRU #: 001892025
3/09/10 AP Request for Tuesday morning inspection.
Thank you.
T /S: March 09, 2010 02:09 PM BSUTTON
B111 02 3/10/10 BS R *BLDG SLAB INSP VRU #: 001893015
3/11/10 AP Request PM inspection.
Need a copy of slab pretreat field report in box. Slab must
be treated before pour
R125 01 3/12/10 TI ONE TRADE ROUGH IN VRU #: 001893882
3/11/10 CA Slab plumbing inspection.
T /S: 03/11/2010 04:47 PM NTART
R125 02 4/08/10 KS ONE TRADE ROUGH IN VRU #: 001906064
4/08/10 AP Separate sheathing inspection. (All 8 Units)
R425 01 4/21/10 BS FOUR TRADE ROUGH IN VRU #: 001911593
4/21/10 DA Framing, Electrical, Mechancial and Plumbing Rough -ins.
1. Need a structural nail plate at center load wall where 3
inch drain is drilled through top plate. also need one at
top plate where front porch beam intersects. 2. Need wedge
anchors in bottom plate in various units within 1 foot of
joints. Ok to insulate
R425 02 4/27/10 BS FOUR TRADE ROUGH IN VRU #: 001914563
4/27/10 AP Insulation inspection; framing re- inspection: plumbing
re- inspection
T /S: April 27, 2010 11:36 AM BSUTTON
R225 01 5/06/10 KS TWO TRADE ROUGH IN VRU #: 001921295
5/06/10 AP Water and Sewer Line Inspection.
R431 01 6/24/10 TI FOUR TRADE FINAL >2500 VRU #: 001945294
6/23/10 CA Final
T /S: 06/23/2010 02:16 PM NTART
CANCELLED FINAL INSPECTION NO ADDRESS CONFIRMATION.
A814 01 6/25/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001945922
6/25/10 AP T /S: 06/25/2010 02:24 PM TWARD
103 WOLF CREEK LN UNIT 22
LILLINGTON 27546
CONTINUED ONTO NEXT PAGE
PREPARED 7/14/10. 9:38:41 INSPECTION TICKET PAGE 10
Harnett_County INSPECTOR: Sutton Brad DATE 7/14/10
ADDRESS . : 103 WOLF CREEK LN SUBDIV:
CONTRACTOR : STAFFORD CUSTOM HOMES PHONE : (910) 692 -9808
OWNER . . : STAFFORD LAND COMPANY INC PHONE : (910) 692 -9808
PARCEL . . : 11 -0670- - -0055- -13-
APPL NUMBER: 09- 50023501 CP NEW RESIDENTIAL (SFA)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
T /S: 06/25/2010 02:25 PM TWARD
R429 01 7/12/10 BS FOUR TRADE FINAL VRU #: 001950823
7/12/10 DA All trade final.
1. Dryer vent flush with wall. 2. Cap unused drains on
attic hvac. 3. Mark unit for heat kit.
R429 02 7/14/10 BS FOUR TRADE FINAL TIME: 17:00 VRU #: 001953249
Reinspection of Final.
T /S: 07/14/2010 08:13 AM NTART
COMMENTS AND NOTES