Loading...
INSPECTIONS PREPARED _'/17/10, 13:59:00 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 3/18/10 ADDRESS . : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER : MGM BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN ON CORNER OF NC 2108 AND BEN COURT, BEN WOODS SUB DIV #1. 2105 APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 210S. STRUCTURE: 000 000 55X55 3BDR - 2BATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 3 /1R /1a h 3/18/10 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 COMMENTS AND NOTES i it Complete Engineering & Consulting, PLLC Michael A. Cavnar P.E. 4721 Ray Road Spring Lake, North Carolina 28390 910 -497 -6703 Fax: 910 -497 -5351 March 18, 2010 From: Michael A. Cavnar RE Engineer Consultant To: Andrew Milton 910- 890 -0555 Cell 407 -479 -3135 Fax Re: Engineering Consulting On March 18, 2010, a site visit was conducted at Benwood Subdivision, 14 Ben Court, Lillington, N.C. to inspect footers only. Concerns from Harnett County inspector was moisture in several areas of the footers. Engineer concluded that no gravel needs to be installed in moist areas. Soils should be adequate for the footers at this date and time. Sincerely, 3' Il lg l 7 ichael A. Cavnar P.E. �� \" ill, *, tees1 * Q- , . � . - = • _1Q • Ad: 2109/ PREPARED 3/22/10, 14:02:42 INSPECTION TICKET PAGE 12 - Harnett County INSPECTOR: IVR DATE 3/23/10 ADDRESS 14 BEN CT SUBDIV: BEN WOODS 101 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : MGM BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN ON CORNER OF NC 210S AND BEN COURT, BEN WOODS SUB DIV #1. 210S APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 210S. STRUCTURE: 000 000 55X55 3BDR 2BATH SFD WITH DECK CRAWL FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION 1 TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poored prior to inspections department examining engineerlreport. Engineered report obtained and no rpair needed. T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR B103 01 3/23/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3 . co AP COMMENTS AND NOTES • I I1 I II PREPARED 3/24/10, 13:58:12 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR I DATE 3/25/10 ADDRESS : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : MGM BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN ON CORNER OF NC 210S AND BEN COURT, BEN WOODS SUB DIV #1. 2105 APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 2105. STRUCTURE: 000 000 55X55 3BDR 2BATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' •'NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION f TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 3101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poored prior to inspections department examining engineer report. Engineered report obtained and no rpair needed. T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR B103 01 3/23/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3/23/10 AP T /S: 03/23/2010 01:40 PM MREARIC B101 02 3/25/10 TI R *BLDG FOOTING / TEMP SVC POLE TIME: 17: VRU #: 001899084 VOICE MESSAGE LEFT T /S: 03/23/2010 03:33 PM NTART '! B105 01 3/25/10 qp TI R *OPEN FLOOR TIME: 17:00 VRU #: 001899582 3 /t'/ /O 'h . A` T /S: 03/24/2010 11:20 AM NTART COMMENTS AND NOTES 1II i I li PREPARED 4/13/10, 13:58:35 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 4/14/10 ADDRESS . : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : M G M BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN ON CORNER OF NC 2105 AND BEN COURT, BEN WOODS SUB DIV #1. 2105 APPROX 4M2 TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 210S. STRUCTURE: 000 000 55X55 3BDR MATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE . : SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poored prior to inspections department examining engineerlreport. Engineered report obtained and no rpair needed. T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR B103 01 3/23/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3/23/10 AP T /S: 03/23/2010 01:40 PM MREARIC B101 02 3/25/10 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17 :00 VRU #: 001899084 3/25/10 AP VOICE MESSAGE LEFT T /S: 03/23/2010 03:33 PM NTART B105 01 3/25/10 DT R *OPEN FLOOR TIME: 17:00 VRU #: 0018991582 3/25/10 AP T /S: 03/24/2010 11:20 AM NTART R425 01 4/14/10 T � FOUR TRADE ROUGH IN VRU #: 001909180 0 I) COMMENTS AND NOTES it PREPARED 4/14/10, 13:59:27 INSPECTION TICKET PAGE 14 Harnett County' INSPECTOR: IVR DATE 4/15/10 ADDRESS . : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : M G M BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN - - -- ON CORNER OF NC 2108 AND BEN COURT, BEN WOODS SUB DIV #1. 2108 APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 2108. STRUCTURE: 000 000 55X55 3BDR 2BATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS l B101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poured prior to inspections department examining engineerlreport. Engineered report obtained and no rpair needed. T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR 8103 01 3/23/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3/23/10 AP T /S: 03/23/2010 01:40 PM MREARIC B101 02 3/25/10 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17: VRU #: 001899084 3/25/10 AP VOICE MESSAGE LEFT T /S: 03/23/2010 03:33 PM NTART B105 01 3/25/10 DT R *OPEN FLOOR TIME: 17:00 VRU #: 001899582 3/25/10 AP T /S: 03/24/2010 11:20 AM NTART R425 01 4/14/10 ►- FOUR TRADE ROUGH IN VRU #: 001909180 4/14/10 DA 1. Missing receptacle for rear of house and for air units. 2. Roof /plumbing boots not complete. 3. No tests on plumbing (water or drain) lines. okay to side. T /S: 04/14/2010 10:42 AM DETAYLOR R425 02 4 15/10 TI S FOUR TRADE ROUGH IN VRU #: 001910212 iv it'( COMMENTS AND NOTES ICI i PREPARED 4/16/10, 13:58:14 INSPECTION TICKET I PAGE 17 Harnett County INSPECTOR: IVR DATE 4/19/10 ADDRESS . : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : MGM BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN - - -- ON CORNER OF NC 2105 AND BEN COURT, BEN WOODS SUB DIV #1. 210S APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 2105. STRUCTURE: 000 000 55X55 3BDR 2BATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW SEPTIC WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS IC I B101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poored prior to inspections department examining engineer report. Engineered report obtained and no rpair needed. T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR B103 01 3/23/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3/23/10 AP T /S: 03/23/2010 01:40 PM MREARIC B101 02 3/25/10 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17n00 VRU #: 001899084 3/25/10 AP VOICE MESSAGE LEFT T /S: 03/23/2010 03:33 PM NTART B105 01 3/25/10 DT R *OPEN FLOOR TIME: 17:00 VRU #: 001899582 3/25/10 AP T /S: 03/24/2010 11:20 AM NTART ' R425 01 4/14/10 DT FOUR TRADE ROUGH IN VRU #: 001909180 4/14/10 DA 1. Missing receptacle for rear of house and for air units. 2. Roof /plumbing boots not complete. 3. No tests on plumbing (water or drain) lines. okay to side. I T /S: 04/14/2010 10:42 AM DETAYLOR R425 02 4/15/10 DT FOUR TRADE ROUGH IN VRU #: 001910212 4/15/10 AP I129 01 4/19/10 I R *INSULATION INSPECTION VRU #: 001911818 i f ii WO ( 7 1;1 ) 32,C - citIC5 COMMENTS AND NOTES III PREPARED 6/29/10, 13:59:56 INSPECTION TICKET I PAGE 14 Harntlt Cohnty INSPECTOR: IVR DATE 6/30/10 v ADDRESS . : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : M G M BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN - - -- I ON CORNER OF NC 2105 AND BEN COURT, BEN WOODS SUB DIV #1. 2105 APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 2105. STRUCTURE: 000 000 55X55 3BDR 2BATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE . . . . . : SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY I • COUNTY PERMIT: CPSF 00 CP • SFD , REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poor prior to inspections department examining engineer report. Engineered report obtained and no rpair needed. II T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR B103 01 3/23/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3/23/10 AP T /S: 03/23/2010 01:40 PM MREARIC B101 02 3/25/10 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00. VRU #: 001899084 3/25/10 AP VOICE MESSAGE LEFT T /S: 03/23/2010 03:33 PM NTART 1 B105 01 3/25/10 DT R *OPEN FLOOR TIME: 17:00 VRU #: 001899582 3/25/10 AP T /S: 03/24/2010 11:20 AM NTART I R425 01 4/14/10 DT FOUR TRADE ROUGH IN VRU #: 001909180 4/14/10 DA 1. Missing receptacle for rear of house and for air units. 2. Roof /plumbing boots not complete. 3. No tests on plumbing (water or drain) lines. okay to side. I T /S: 04/14/2010 10:42 AM DETAYLOR R425 02 4/15/10 DT FOUR TRADE ROUGH IN VRU #: 001910212 I 4/15/10 AP 4 I129 01 4/19/10 DT R *INSULATION INSPECTION VRU #: 001911818 4/19/10 AP Insulation missing around rear kitchen nook windows. T /S: 04/19/2010 09:56 AM DETAYLOR H824 01 5/27/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001933456 5/27/10 AP PER OLIVER TOLKSDORF OPERATIONS PERMIT ONIHOLD FOR PUMP AND ALARM TO BE CHECKED. T /S: 05/27/2010 08:44 AM SSTEWART / T /S: 05/27/2010 08:45 AM SSTEWART H824 02 6/09/10 OT V ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001939131 6/09/10 AP T /S: 06/10/2010 09:26 AM SZIMMER T /S: 06/10/2010 09:28 AM SZIMMER A814 01 6/29/10 FS ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001947738 6/29/10 AP T /S: 06/29/2010 10:56 AM NTART T /S: 06/29/2010 11:02 AM FBURGESS I CONTINUED ONTO NEXT PAGE PREPARED 6/29/10, 13:59:56 INSPECTION TICKET PAGE 15 Harnept County INSPECTOR: IVR DATE 6/30/10 it ADDRESS 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER : M G M BUILDERS PHONE : PARCEL 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS \ BEN CT BUNNLEVEL, NC 28323 LOT 1 R429 01 6/30/10 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 001947746 (0) DA T /S: 06/29/2010 11:03 AM NTART COMMENTS AND NOTES j it Violation Notice Do Not Remove Harnett County Inspection Department 102 East Front St P.O. Box 65 Llllington, NC 27546 Phone (910) 893-7525 Fax (910) 893 -2793 07- 50016756 June 30, 2010 1. Need positive drainage around home and any vent within 4 inches of ground shall have vent well. 2. Rose bibs not secured to house. 3. Need cleanout brought up to grade outside of foundation. 4. Water heater shall be raised or door sealed to prevent fumes from entering closet in garage. 5. Seal Freon linesets at unit in crawl space. 6. Rear steps shall have hand rail. (more than 3 risers) Ken Slattum Code Administrator PREPARED 7/08/10, 14:07:45 INSPECTION TICKET j PAGE 8 Harnett-County INSPECTOR: IVR DATE 7/09/10 ADDRESS . : T4 :BE1N CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : MGM BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/08/2009 03:29 PM VBROWN ON CORNER OF NC 2105 AND BEN COURT, BEN WOODS SUB DIV #1. 2105 APPROX 4MI TO LEFT ON TO BEN COURT LOT ON CORNER OF BEN COURT AND NC 210S. l5S Z.O S2. g STRUCTURE: 000 000 55X55 3BDR 2BATH SFD WITH DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING'' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 3/18/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001896041 3/18/10 AP Need engineer soil report. Concrete poored prior to inspections department examining engineerRreport. Engineered report obtained and no rpair needed. T /S: 03/18/2010 12:30 PM DETAYLOR T /S: 03/18/2010 01:05 PM DETAYLOR T /S: 03/19/2010 02:02 PM DETAYLOR 8103 01 3/23/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001898361 3/23/10 AP T /S: 03/23/2010 01:40 PM MREARIC B101 02 3/25/10 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001899084 3/25/10 AP VOICE MESSAGE LEFT T /S: 03/23/2010 03:33 PM NTART 8105 01 3/25/10 DT R *OPEN FLOOR TIME: 17:00 VRU #: 001899582 3/25/10 AP T /S: 03/24/2010 11:20. AM NTART R425 01 4/14/10 DT FOUR TRADE ROUGH IN VRU #: 001909180 4/14/10 DA 1. Missing receptacle for rear of house and for air units. 2. Roof /plumbing boots not complete. 3. No tests on plumbing (water or drain) lines. okay to side. T /S: 04/14/2010 10:42 AM DETAYLOR R425 02 4/15/10 DT FOUR TRADE ROUGH IN VRU #: 001910212 4/15/10 AP I129 01 4/19/10 DT R *INSULATION INSPECTION VRU #: 001911818!, 4/19/10 AP Insulation missing around rear kitchen nook windows. T /S: 04/19/2010 09:56 AM DETAYLOR H824 01 5/27/10 OT */ ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001933456 5/27/10 AP PER OLIVER TOLKSDORF OPERATIONS PERMIT ON HOLD FOR PUMP AND ALARM TO BE CHECKED. T /S: 05/27/2010 08:44 AM SSTEWART T /S: 05/27/2010 08:45 AM SSTEWART H824 02 6/09/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001939131 6/09/10 AP T /S: 06/10/2010 09:26 AM SZIMMER T /S: 06/10/2010 09:28 AM SZIMMER A814 01 6/29/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001947738 6/29/10 AP T /S: 06/29/2010 10:56 AM NTART T /S: 06/29/2010 11:02 AM FBURGESS CONTINUED ONTO NEXT PAGE PREPARED 7/08/10, 14:07:45 INSPECTION TICKET PAGE 9 Harnett, County INSPECTOR: IVR DATE 7/09/10 ADDRESS . : 14 BEN CT SUBDIV: BEN WOODS 10 LOTS CONTRACTOR : TIMELESS RESIDENTAL CONST LLC PHONE : (910) 890 -0555 OWNER . . : M G M BUILDERS PHONE : PARCEL . . : 12 -0547- - -0013- -03- APPL NUMBER: 09- 50023355 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS y14 BEN CT BUNNLEVEL, NC 28323 LOT 1 R429 01 6/30/10 FOUR TRADE FINAL TIME: 17:00 VRU #: 001947746 6/30/10 DA T /S: 06/29/2010 11:03 AM NTART 1. Need cleanout up to grade. 2. Need positive drainage and ventwells if required. 3. Hose bibs not secured. 4. Water heater shall be raised or seal door 5. Seal freon linesets at unit 6. Rear steps shall have handrail T /S: 06/30/2010 10:41 AM KSLATTUM R429 02 7/09/10 TI FOUR TRADE FINAL VRU #: 001951748 — 2/111 6 14 COMMENTS AND NOTES �V. ` ;., ‘C 1:77,ynm'+ .r .1 `r a T 71 '0°'S' 7 AT 7 a a 47 4 :7J; , i ' t J'r r fi'+ °' Pl j If , _ �,., T. P ' \ ' kf a \ w � %s �'s; ''�i r m r L A AL dz : r b County,of Harnett • Building Inspections Department \ Planning Services P Certificate of Compliance: Occupancy: )( ' Certificate issued pursuant to the r equirements of North Carolina General Statute 153A�363 and Harnett ip,.. County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: Res \A an 4-4 , Permit Numbers `.'= Name: I"; r less R., s '�AP,�ti w.I (�µ�i. Building: 5 ecrical: 4) ,- Address: 14 Bevn C-} Insulation: t O� J El Bvnnievtcl , 1 C 28'12' Plumbing: r Mechanical: Q 4 MFG Home: 7. k ;;; n. Date: 7 / 1 Ito Building Official: s> ' r_____' jp tia; .,, i 3*.qc„, ,2 ,... 7, , ,....,1 7 . t 777* 7777; , .7,1 4