INSPECTIONS PREPARED 2/12/10, 13:58:10 INSPECTION TICKET PAGE 21 Harnett ?aunty, INSPECTOR: IVR DATE 2/15/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 7 -rf in nA -M COMMENTS AND NOTES PREPARED 3/03/10, 14:01:06 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 3/04/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillina on, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 03 -04 -10 PERMIT # 09- 50023328 ADDRESS: 202 lakeland port VIOLATIONS: 1. Damp -proof the foundation.. I will check it on open floor insp. 2. Install a drain hole at lowest point of foundation 3. The porch area, if filled, exceeds the height of an 8" masonry wall with unbalanced fill .. see table R404.1.1 ... engineer is required Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 4/14/10, 8:02:51 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 3/06/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101'01- 2/15/10 -MR : R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500'' "' 2/15/10 DA T /S: 02/15/2010 12:52 PM ' MREARIC ---- - - 8 2x2x12" point loads are missing - -- -- -- -- B10102 2/16/10 MR' R *BLDG FOOTING / TEMP SVC POLE '" VRU #. :'- 001883529 '. 2/16/10 AP ` ':T /S: 02/16/2010 11:55 AM MREARIC ' B103 o1. .. 3/04/10 MR - R *BLDG -FOUND & TEMP SVC POLE VRU #i'001890270 - -- 3/04/10'' DA -, - T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation - -- - install a foundation drain - - - -. -. -- " -- "'" ' porch area is too tall for fill eithout engineering B103'02 3/06/10 TT' ' • R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001909928 "'!3 •e -,c ,4f —ff T /Si 04/14/2010 08:02 AM 'NTART. COMMENTS AND NOTES • PREPARED 3/08/10, 13:58:54 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 3/09/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES 'RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . i JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing 8101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain porch area is too tall for fill eithout engineering A814 01 3/09/10 TI ADDRESS CONFIRMATION VRU #: 001890289 B105 01 3/09/10 TI (j R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 '3 ,`j - -�o r4fi(4g, T /S: 03/08/2010 10:36 AM NTART COMMENTS AND NOTES PREPARED 4/06/10, 13:58:26 INSPECTION TICKET PAGE 14 Harnett..:Coun t INSPECTOR: IVR DATE 4/07/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 3101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain porch area is too tall for fill eithout engineering A814 01 3/09/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001890289 3/12/10 AP 202 Lakeland port sanford 27332 T /S: 03/12/2010 09:43 AM TWARD B105 01 3/09/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 3/09/10 AP T /S: 03/08/2010 10:36 AM NTART T /S: 03/09/2010 12:27 PM MREARIC R425 01 4/06/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001904838 4/05/10 CA T /S: 04/05/2010 09:43 AM NTART R425 02 4/07/10 TI _ FOUR TRADE ROUGH IN VRU #: 001905868 '1, 7 - 10 ( P'Jk COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 04 -07 -10 PERMIT # 09- 50023328 ADDRESS: 202 lakeland port VIOLATIONS: 1. Firecaulk above fireplace 2. Electric not complete 3. Pex pipe must be checked with water in pipe not air 4. Ok to side house Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 4/08/J.0, 13:58:34 INSPECTION TICKET PAGE 20 Harnett County 4 - INSPECTOR: IVR DATE 4/09/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain porch area is too tall for fill eithout engineering A814 01 3/09/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001890289 3/12/10 AP 202 lakeland port sanford 27332 T /S: 03/12/2010 09:43 AM TWARD B105 01 3/09/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 3/09/10 AP T /S: 03/08/2010 10:36 AM NTART T /S: 03/09/2010 12:27 PM MREARIC R425 01 4/06/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001904838 4/05/10 CA T /S: 04/05/2010 09:43 AM NTART R425 02 4/07/10 FOUR TRADE ROUGH IN VRU #: 001905868 4/07/10 DA T /S: 04/07/2010 12:55 PM MREARIC firecaulk over fireplace electric not complete pex needs water test not air ok to side house R425 03 4/09/10 TI FOUR TRADE ROUGH IN VRU #: 001907477 - M� COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 04 -09 -10 PERMIT # 10- 50023328 ADDRESS: 202 lakeland port VIOLATIONS: 1. You cannot use aluminum to flash the front porch at concrete junction 2. Ok to side but not the front porch. I will check it on the insulation inspection Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 4/12/10, 13:59:00 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 4/13/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain porch area is too tall for fill eithout engineering A814 01 3/09/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001890289 3/12/10 AP 202 lakeland port sanford 27332 T /S: 03/12/2010 09:43 AM TWARD B105 01 3/09/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 3/09/10 AP T /S: 03/08/2010 10:36 AM NTART T /S: 03/09/2010 12:27 PM MREARIC R425 01 4/06/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001904838 4/05/10 CA T /S: 04/05/2010 09:43 AM NTART R425 02 4/07/10 MR FOUR TRADE ROUGH IN VRU #: 001905868 4/07/10 DA T /S: 04/07/2010 12:55 PM MREARIC firecaulk over fireplace electric not complete pex needs water test not air ok to side house R425 03 4/09/10 i' FOUR TRADE ROUGH IN VRU #: 001907477 4/09/10 T /S: 04/09/2010 01:30 PM MREARIC aluminum flashing not allowed on porch ok to side and insulatae but not front porch I129 01 4/13/10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001908649 2)t3-/o , 1 p ( T /S: 04/12/2010 10:37 AM NTART R425 04 4/13/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001908631 ¥ Af -n� �g T /S: 04/12/2010 10:37 AM NTART COMMENTS AND NOTES PREPARED 4/26/10, 13:59:49 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 4/27/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain porch area is too tall for fill eithout engineering B103 02 3/06/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001909928 3/06/10 AP T /S: 04/14/2010 08:02 AM NTART T /S: 04/14/2010 08:03 AM NTART A814 01 3/09/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001890289 3/12/10 AP 202 lakeland port sanford 27332 T /S: 03/12/2010 09:43 AM TWARD B105 01 3/09/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 3/09/10 AP T /S: 03/08/2010 10:36 AM NTART T /S: 03/09/2010 12:27 PM MREARIC R425 01 4/06/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001904838 4/05/10 CA T /S: 04/05/2010 09:43 AM NTART R425 02 4/07/10 MR FOUR TRADE ROUGH IN VRU #: 001905868 4/07/10 DA T /S: 04/07/2010 12:55 PM MREARIC firecaulk over fireplace electric not complete pex needs water test not air ok to side house R425 03 4/09/10 MR FOUR TRADE ROUGH IN VRU #: 001907477 4/09/10 DA T /S: 04/09/2010 01:30 PM MREARIC aluminum flashing not allowed on porch ok to side and insulatae but not front porch I129 01 4/13/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001908649 4/13/10 AP T /S: 04/12/2010 10:37 AM NTART T /S: 04/13/2010 01:21 PM MREARIC R425 04 4/13/10 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001908631 4/13/10 AP T /S: 04/12/2010 10:37 AM NTART T /S:, 04/13/2010 01:21 PM MREARIC B113 01 4/27/10 TI R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001915867 y - 21* )0 A P —O T /S: 04/26/2010 10:12 AM NTART COMMENTS AND NOTES PREPARED 6/17/10, 14:06:02 INSPECTION TICKET PAGE 13 Harett; INSPECTOR: IVR DATE 6/18/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 542(38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain Porch area is too tall for fill eithout engineering B103 02 3/06/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001909928 3/06/10 AP T /S: 04/14/2010 08:02 AM NTART T /S: 04/14/2010 08:03 AM NTART A814 01 3/09/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001890289 3/12/10 AP 202 lakeland port sanford 27332 T /S: 03/12/2010 09:43 AM TWARD B105 01 3/09/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 3/09/10 AP T /S: 03/08/2010 10:36 AM NTART T /S: 03/09/2010 12:27 PM MREARIC R425 01 4/06/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001904838 4/05/10 CA T /S: 04/05/2010 09:43 AM NTART R425 02 4/07/10 MR FOUR TRADE ROUGH IN VRU #: 001905868 4/07/10 DA T /S: 04/07/2010 12:55 PM MREARIC firecaulk over fireplace electric not complete pex needs water test not air ok to side house R425 03 4/09/10 MR FOUR TRADE ROUGH IN VRU #: 001907477 4/09/10 DA T /S: 04/09/2010 01:30 PM MREARIC aluminum flashing not allowed on porch ok to side and insulatae but not front porch I129 01 4/13/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001908649 4/13/10 AP T /S: 04/12/2010 10:37 AM NTART T /S: 04/13/2010 01:21 PM MREARIC R425 04 4/13/10 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001908631 4/13/10 AP T /S: 04/12/2010 10:37 AM NTART T /S: 04/13/2010 01:21 PM MREARIC B113 01 4/27/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001915867 4/27/10 AP T /S: 04/26/2010 10:12 AM NTART T /S: 04/27/2010 01:57 PM MREARIC CONTINUED ONTO NEXT PAGE PREPARED 6/17/10, 14:06:02 INSPECTION TICKET PAGE 14 Hargett CCunt INSPECTOR: IVR DATE 6/18/10 ADDRESS . : 202 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R429 01 6/18/10 TI FOUR TRADE FINAL VRU #: 001942660 4•/ a -In DP - /�� COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 06 -18-10 PERMIT # 09- 50023328 ADDRESS: 202 lakeland port VIOLATIONS: 1. You cannot have a panbelboard in the bathroom (E) Not Located in Bathrooms. In dwelling units and guest rooms or guest suites of hotels and motels, overcurrent devices, other than supplementary overcurrent protection, shall not be located in bathrooms 2. Plans do not show the toilet in the laundry room, have it approved by environ, and bldg. dept 3. Install secondary drain to outside on air handler or float switch Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 6/29/10, 13:59:56 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 6/30/10 ADDRESS : A2 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR -: JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 54X38 3 BR ATT GARAGE DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/15/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882500 2/15/10 DA T /S: 02/15/2010 12:52 PM MREARIC 8 2x2x12" point loads are missing B101 02 2/16/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001883529 2/16/10 AP T /S: 02/16/2010 11:55 AM MREARIC B103 01 3/04/10 MR R *BLDG FOUND & TEMP SVC POLE VRU #: 001890270 3/04/10 DA T /S: 03/04/2010 11:58 AM MREARIC damp -proof foundation install a foundation drain porch area is too tall for fill eithout engineering B103 02 3/06/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001909928 3/06/10 AP T /S: 04/14/2010 08:02 AM NTART T /S: 04/14/2010 08:03 AM NTART A814 01 3/09/10 TW . / CONFIRMATION TIME: 17:00 VRU #: 001890289 3/12/10 AP Y '202 lakeland port sanford 27332 T /S: 03/12/2010 09:43 AM TWARD B105 01 3/09/10 MR R *OPEN FLOOR TIME: 17:00 VRU #: 001891928 3/09/10 AP T /S: 03/08/2010 10:36 AM NTART T /S: 03/09/2010 12:27 PM MREARIC R425 01 4/06/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001904838 4/05/10 CA T /S: 04/05/2010 09:43 AM NTART R425 02 4/07/10 MR FOUR TRADE ROUGH IN VRU #: 001905868 4/07/10 DA T /S: 04/07/2010 12:55 PM MREARIC firecaulk over fireplace electric not complete pex needs water test not air ok to side house R425 03 4/09/10 MR FOUR TRADE ROUGH IN VRU #: 001907477 4/09/10 DA T /S: 04/09/2010 01:30 PM MREARIC aluminum flashing not allowed on porch ok to side and insulatae but not front porch I129 01 4/13/10 MR R *INSULATION INSPECTION TIME: 17:00 VRU #: 001908649 4/13/10 AP T /S: 04/12/2010 10:37 AM NTART T /S: 04/13/2010 01:21 PM MREARIC R425 04 4/13/10 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001908631 4/13/10 AP T /S: 04/12/2010 10:37 AM NTART T /S: 04/13/2010 01:21 PM MREARIC B113 01 4/27/10 MR R *BLDG WATER /DAMP PROOFING TIME: 17:00 VRU #: 001915867 4/27/10 AP T /S: 04/26/2010 10:12 AM NTART T /S: 04/27/2010 01:57 PM MREARIC CONTINUED ONTO NEXT PAGE PREPARED 6/29/10, 13:59:56 INSPECTION TICKET PAGE 11 Harnett Cpunty INSPECTOR: IVR DATE 6/30/10 ADDRESS . : 2 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR, : JAMES RAY CONSTRUCTION PHONE : (910) 893 -3281 OWNER . . : JAMES RAY CONSTRUCTION #122 PHONE : (910) 893 -5063 PARCEL . . : 03- 9585 -15- -0122- - - APPL NUMBER: 09- 50023328 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R429 01 6/18/10 MR FOUR TRADE FINAL VRU #: 001942660 6/18/10 DA T /S: 06/18/2010 02:41 PM NTART VIOLATIONS: 1 -YOU CANNOT HAVE A PANELBOARD IN THE BATHROOM. (E) NOT LOCATED IN BATHROOMS. IN DWELLING UNITS AND GUEST ROOMS OR GUEST SUITES OF HOTELS OR MOTELS, OVERCURRENT DEVICES, OTHER THAN SUPPLEMENTARY OVERCURRENT PROTECTION, SHALL NOT BE LOCATED IN BATHROOMS. R429 02 6/30/10 TI FOUR TRADE FINAL VRU #: 001947834 6 3oti A9 -MR COMMENTS AND NOTES t I , h AT ; :. ;7 i t wt' r: rsrg"rfmtrev ;rR°y.wrvq-'yprr r,, -e+ t - Ir,;` r r ; Co t t p i 's +ry s+ i ^;,r11 - ik ?44 ' -\ ''S " ' I:#C 1 47k 'M :m* A t ''fr".sk' " 'fr ."' ft County of Harnett Building Inspections Department • ' Planning Services r Certificate of Compll annce:s, Occupancy: x Certificate issued ursuant to the requirements of North Carolina General Statute 153A -363 and Harnett , ,, P 9 County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: ; Use Classification: f', -3 Permit Numbers p Name: -Mum p s ' ° r Coustructiou Building: n9- Snn z ti 8 Electrical: ' 1 r. Address: Insulation: ' 1 2n Lake.lroko/ fnrt Plumbing: I' Mechanical: \`7 4 ,� MFG Home: ` Date: 6, 30- ten Building Official: `r wt. / ,/ 4.L4.1 4.:1)..4) 4)1 )) i " i , ,717,1m.. Nur ‘ylviivi % ) i)