Loading...
INSPECTIONS PREPARED 4/22/10, 14:02:12 INSPECTION TICKET PAGE 50 Harnett County INSPECTOR: IVR DATE 4/23/10 ADDRESS . : 16 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS & CATES BUILDING AND PHONE : (910) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -09- -0282- -04- APPL NUMBER: 10- 50024164 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/09/2010 10:33 AM RDCONTE - -- 273 REGIMENTAL / THE COLONY ® LEX #79 TAKE 27W GO APPROX 17.5MI, MERGE LEFT ONTO NC87. GO APPROX 4.5MI, T/L ON PLANTATION DR. T/R ON CRUTCHFIELD DR. T/R ON SCRANTON CT. * * *PWR CO: CENTRAL ELECTRIC * ** STRUCTURE: 000 000 44.5X39 SLAB 3BD /2.5BA W/ GAR FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 4/21/10 DT R *PLUMB UNDER SLAB VRU #: 001913512 4/21/10 AP A814 01 4/23/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001914951 T /S: 04/22/2010 02:01 PM NTART B125 01 4/23/10 TI R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001914712 t %(Z3110 fkf I)( T /S: 04/22/2010 12:39 PM VBROWN COMMENTS AND NOTES PREPARED 5/11/10, 14:03:22 INSPECTION TICKET PAGE 30 Harnett County INSPECTOR: IVR DATE 5/12/10 ADDRESS . : 16 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS & CATES BUILDING AND PHONE : (910) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . : 09- 9565 -09- -0282- -04- APPL NUMBER: 10- 50024164 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/09/2010 10:33 AM RDCONTE - -- 273 REGIMENTAL / THE COLONY @ LEX #79 TAKE 27W GO APPROX 17.5MI, MERGE LEFT ONTO NCS7. GO APPROX 4.5MI, T/L ON PLANTATION DR. T/R ON CRUTCHFIELD DR. T/R ON SCRANTON CT. * * *PWR CO: CENTRAL ELECTRIC * ** STRUCTURE: 000 000 44.5X39 SLAB 3BD /2.5BA W/ GAR FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 4/21/10 DT R *PLUMB UNDER SLAB VRU #: 001913512 4/21/10 AP A814 01 4/23/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001914951 4/26/10 AP T /S: 04/22/2010 02:01 PM NTART 16 CENTURY DR LOT 79 CAMERON 28326 T /S: 04/26/2010 08:29 AM TWARD B125 01 4/23/10 DT R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001914712 4/23/10 AP T /S: 04/22/2010 12:39 PM VBROWN R425 01 5/12/10 FOUR TRADE ROUGH IN VRU #: 001924733 C7121/0 E207 01 5/12/10 T�I R *ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 001924802 57U00 ll° T /S: 05/11/2010 01:44 PM NTART COMMENTS AND NOTES PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 47 Harnett County INSPECTOR: IVR DATE 5/14/10 ADDRESS . : 16 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS & CATES BUILDING AND PHONE : (910) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -09- -0282- -04- APPL NUMBER: 10- 50024164 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/09/2010 10:33 AM RDCONTE - -- 273 REGIMENTAL / THE COLONY @ LEX #79 TAKE 27W GO APPROX 17.5MI, MERGE LEFT ONTO NC87. GO APPROX 4.5MI, T/L ON PLANTATION DR. T/R ON CRUTCHFIELD DR. T/R ON SCRANTON CT. * * *PWR CO: CENTRAL ELECTRIC * ** STRUCTURE: 000 000 44.5139 SLAB 3BD /2.5BA W/ GAR FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 4/21/10 DT R *PLUMB UNDER SLAB VRU #: 001913512 4/21/10 AP A814 01 4/23/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001914951 4/26/10 AP T /S: 04/22/2010 02:01 PM NTART 16 CENTURY DR LOT 79 CAMERON 28326 T /S: 04/26/2010 08:29 AM TWARD 8125 01 4/23/10 DT R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001914712 4/23/10 AP T /S: 04/22/2010 12:39 PM VBROWN R425 01 5/12/10 - FOUR TRADE ROUGH IN VRU #: 001924733 5/12/10 DA 1. Al and A2 trusses not strapped for enough uplift at jnt12 2. Window withing 60 inches of walking surface at stairs must be tempered. 3. Need receptacle at rear of house outside porch. Okay to side and insulate T /S: 05/12/2010 10:34 AM DETAYLOR E207 01 5/12/10 DT R *ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 001924802 5/12/10 AP T /S: 05/11/2010 01:44 PM NTART I129 01 5 14/10 T]y, D R *INSULATION INSPECTION VRU #: 001926296 R425 02 5/14/10 TI Y � , I FOUR TRADE ROUGH IN VRU #: 001926287 COMMENTS AND NOTES PREPAID 6/22/10, 13:59:55 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 6/23/10 ADDRESS . : 16 CENTURY DR SUBDIV: LEXINGTON PLANTATION INV LLC CONTRACTOR : CAVINESS & CATES BUILDING AND PHONE : (910) 481 -0503 OWNER . . : LEXINGTON PLANTATION INVESTORS PHONE : PARCEL . . : 09- 9565 -09- -0282- -04- APPL NUMBER: 10- 50024164 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/09/2010 10:33 AM RDCONTE - -- 273 REGIMENTAL / THE COLONY @ LEX #79 TAKE 27W GO APPROX 17.5MI, MERGE LEFT ONTO NC87. GO APPROX 4.5MI, T/L ON PLANTATION DR. T/R ON CRUTCHFIELD DR. T/R ON SCRANTON CT. * * *PWR CO: CENTRAL ELECTRIC * ** STRUCTURE: 000 000 44.5E39 SLAB 3BD /2.5BA W/ GAR FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 4/21/10 DT R *PLUMB UNDER SLAB VRU #: 001913512 4/21/10 AP A814 01 4/23/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001914951 4/26/10 AP T /S: 04/22/2010 02:01 PM NTART \/16 CENTURY DR LOT 79 CAMERON 28326 T /S: 04/26/2010 08:29 AM TWARD B125 01 4/23/10 DT R *BLDG MONOLITHIC SLAB TIME: 17:00 VRU #: 001914712 4/23/10 AP T /S: 04/22/2010 12:39 PM VBROWN R425 01 5/12/10 DT FOUR TRADE ROUGH IN VRU #: 001924733 5/12/10 DA 1. Al and A2 trusses not strapped for enough uplift at jnt12 2. Window withing 60 inches of walking surface at stairs must be tempered. 3. Need receptacle at rear of house outside porch. Okay to side and insulate T /S: 05/12/2010 10:34 AM DETAYLOR E207 01 5/12/10 DT R *ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 001924802 5/12/10 AP T /S: 05/11/2010 01:44 PM NTART I129 01 5/14/10 KS R *INSULATION INSPECTION VRU #: 001926296 5/14/10 AP R425 02 5/14/10 KS FOUR TRADE ROUGH IN VRU #: 001926287 5/14/10 AP R429 01 6/23/10 TI FOUR TRADE FINAL VRU #: 001945097 4 Ye A& )r COMMENTS AND NOTES r s, , e`er . 77 7 N s 2 ,z. ''f'F. 1 M '"S ? ".. 7P7a' i t County of Harnett Building Inspections Department ti Planning Services Certificate of Compliance: Occupancy: X Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett \,3 . ' TTT County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the 1. various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: N . Use Classification: Pr s I Ae,n- --,` .- l Permit Numbers r` Name: Cav , ,nrsc 4- ro.1-c n Building: lk . : Electrical: \ I0 's Address: Ib [en - y r t - r Insulation: �� : i ls�. rnn N 7--g S (o Plumbing: I� • Mechanical: VO K lllyyy {��� r MFG Home: Date: ( 1 2 3 I / t) Building Official > ,-----,,- ` iii if �. t i �i,f cif ∎ `� > ,s`1' 1'.7 � t ., r ,i 3 , .,