INSPECTIONS PREPARED 4/26/10, 13:59:49 INSPECTION TICKET PAGE 72 Harnett County INSPECTOR: IVR DATE 4/27/10 ADDRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : DUNCAN DEVELOPMENT LLC PHONE : PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - -- 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CUS * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 01 CP * REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 TI R*BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 1 -t- ( 77- - 10 COMMENTS AND NOTES PREPARED 4/29/10, 13:58:27 INSPECTION TICKET PAGE 42 Harnett County INSPECTOR: IVR DATE 4/30/10 ADDRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : DUNCAN DEVELOPMENT LLC PHONE : PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - -- 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CUS * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 01 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 B5 R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 4/27/10 AP .T /S: April 27, 2010 11:00 AM BSUTTON B103 01 4/30/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001918241 L+.12 -l© A.P COMMENTS AND NOTES „G71 7 1 PREPARED 5/04/10, 14:05:39 INSPECTION TICKET PAGE 28 Harnett County INSPECTOR: IVR DATE 5/05/10 ADDRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : DUNCAN DEVELOPMENT LLC PHONE : PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CUS * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF O1 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 4/27/10 AP T /S: April 27, 2010 11:00 AM BSUTTON B103 01 4/30/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001918241 4/30/10 AP T /S: April 30, 2010 10:42 AM BSUTTON B105 01 5/05/10 xeric R *OPEN FLOOR VRU #: 001920540 A814 01 5/05/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001918250 4/30/10 AP 600 COKESBURY PARK LN FUQUAY VARINA 27526 T /S: 04/30/2010 09:46 AM TWARD COMMENTS AND NOTES PREPARED 5 /11 /10, 14:03:22 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 5/12/10 ADDRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : DUNCAN DEVELOPMENT LLC PHONE : PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - -- 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CUS * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY - COUNTY PERMIT: CPSF 01 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 4/27/10 AP T /S: April 27, 2010 11:00 AM BSUTTON B103 01 4/30/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001918241 4/30/10 AP T /S: April 30, 2010 10:42 AM BSUTTON B105 01 5/05/10 BS R *OPEN FLOOR VRU #: 001920540 5/05/10 AP T /S: May 05, 2010 11:50 AM BSUTTON A814 01 5/05/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001918250 4/30/10 AP 600 COKESBURY PARK LN FUQUAY VARINA 27526 T /S: 04/30/2010 09:46 AM TWARD R425 01 5/12/10 TI FOUR TRADE ROUGH IN VRU #: 001924840 .5 l° _ COMMENTS AND NOTES ,,:*.PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 40 Harnett County INSPECTOR: IVR DATE 5/14/10 ADDRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER. . : DUNCAN DEVELOPMENT LLC PHONE ;PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - -- 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CU5 * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 01 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 4/27/10 AP T /S: April 27, 2010 11:00 AM BSUTTON B103 01 4/30/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001918241 4/30/10 AP T /S: April 30, 2010 10:42 AM BSUTTON 3105 01 5/05/10 BS R *OPEN FLOOR VRU #: 001920540 5/05/10 AP T /5: May 05, 2010 11:50 AM BSUTTON A814 01 5/05/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001918250 4/30/10 AP 600 COKESBURY PARK LN FUQUAY VARINA 27526 T /S: 04/30/2010 09:46 AM TWARD R425 01 5/12/10 B. FOUR TRADE ROUGH IN VRU #: 001924840 5/12/10 DP 1. No baffles /firestop. 2. Beam added inceiling at end of hall, not shown on plan, no support. 3. No header over bath entry door. Inspection stopped do not side /insulate $50 re fee R425 02 g14/10 4I „ FOUR TRADE ROUGH IN VRU #: 001925734 1 4/0 lajt_ COMMENTS AND NOTES 1 111 1111SIMERVIIIIISIIITIMEWOUWIPAI2i IOTIIIBIITOIIIIMMIKIIMIMIIIMMMMIIIIIIIIIIMIME Apr. 14. 2013 3 20PY AD, 3353 P. 3 • 2SC •••—■ 1 X •-• 0 EN r` 1 Di 0.1 Z i zd F ..L u - / \ \ o ? 0 o / CJ LA / c x 0 / 2SC ...., _ ( )1 7- 1 () i 2SC ( % ) , 1 1 1 J 1 I 1 1/2 WALL 1 X e) 6.1) )1f (,) ( , ■ / 7 I A I or 11 94 TY1NDALL ENGLNEE RING k orsic14 P A •--, .01..F, go . .... : k 0 Ili m uni • ...I'M TM ti Mt IKVISIONI ARO 11E00111W/ 01301 .. SI•to..sh DWI • Cuncr • Noml, Cud on . 1.4111 • .0 CC es , i t • : v. trehintlinneo2 I 4m DILOIM I I 11111. —a ••• AA Cli 01/13/1D II I 00A1Z-0001 WEB STANCIL BUILDERS, INC oulvHorannitA, atv 466 STANCH. RD JOHNSTON IstAn• e , ..C. 1 of 3 ANGIER, NC 27 SDI l"(4 44. u h‘ IV Ar , attiso 4 X01. 2010 3 204 • No. 3353 P. 4 c.: I w L • - -- NEW ilI �1I 1 co I a.- SUPPORT �,. �r3 SEE SHEET 3 co u FOR OPTIONS I _: _ 2 Y.In @ IE/ 0 c ,L., tNI I -t in — I I I IMO ittr;LtUiii4,61, ., iiri ENGINEERING b. A. �; s . 1JV � � /. ' /4 mm.cna .nmm+ul 8 / Q • e15pe•uAOie.. Canis/ • Noun Ond. • MP e[mI� ucoenae mu[ ...ry•.A4.pudp •.:n pwawn: [ TG PROJECT n • E AA I� PT II 04 /13 /10 1 IOOA$.0001 `, ;.` a STANCIL BUILDERS. INC. !Mans L .. ,E pEewasnmoT& e 4� c. ANOIER 01 ten.: NC 2 of 3 ,, ' / p , 1 i1 S _ e 04-1- A)r.14. 2010 3:20PM No. 3353 P. 5 NEW 8Px CMU PIER • GRADE NEW 12 "x20 "x6" THICK CONCRETE FOOTING OPTION 1 NEW 4x4 POST • NEW 12 "x12 "x6" THICK CONCRETE FOOTING GRADE • • OPTION 2 • wj TYNDALL ! ,►' - : • e ENGINEERING 14OESIGN, A . a _ Iy�n 6j ,.YOU.,an msne n0, PATE EEVIYIONI Apo MORD OE GIVE 4o n W0..0 DINI • 4•nn Pier* C.n4u • >m. n". ea +lv ^AaYsl4.awa�.u naZ OIIF. miner" 4 E.y1D 9 AA II PT II 04!17 /10 I00AR -0001 , { 'P Ilan STANCE. BUILDERS, INC. L "Lives , rMnna EL I Idd STANCIL RD lu. _.. • akIT a.n� 3 o f3 7 � P , ANGIER, NC 21501 16 1i,�A 1' � ,3 1� PREPARED 5/17/10, 15:09:44 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 5/18/10 ;Sr AILtRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . : DUNCAN DEVELOPMENT LLC PHONE : PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - -- 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CUS * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY - COUNTY PERMIT: CPSF 01 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 4/27/10 AP T /S: April 27, 2010 11:00 AM BSUTTON B103 01 4/30/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001918241 4/30/10 AP T /S: April 30, 2010 10:42 AM BSUTTON B105 01 5/05/10 BS R *OPEN FLOOR VRU #: 001920540 5/05/10 AP T /S: May 05, 2010 11:50 AM BSUTTON A814 01 5/05/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001918250 4/30/10 AP 600 COKESBURY PARK LN FUQUAY VARINA 27526 T /S: 04/30/2010 09:46 AM TWARD R425 01 5/12/10 BS FOUR TRADE ROUGH IN VRU #: 001924840 5/12/10 DP 1. No baffles /firestop. 2. Beam added inceiling at end of hall, not shown on plan, no support. 3. No header over bath entry door. Inspection stopped do not side /insulate $50 re fee R425 02 5/14/10 (S FOUR TRADE ROUGH IN VRU #: 001925734 5/14/10 U 1. Need engineers repair on girder overnotched for washing machine drain. Ok to side /insulate I129 01 5/18 10 T R *INSULATION INSPECTION VRU #: 001927954 - I •fa Alf) R425 03 5/1 /10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001928241 T /S: 05/17/2010 03:07 PM NTART COMMENTS AND NOTES P- TYNDALL ® ENGINEERING & DESIGN, R.A. r 919923 .1200 • r 9197739658 69Shipwash Drive • Garner • North Carolina • 22529 w ww.tyndellen 9inee rinq,aam May 17, 2010 Stencil Builders 406 Stencil Rd. Angier, NC 27501 Email: frovlauplazola (a embargmail.com Faxed to: 919- 639 -8841 Reference: Engineering Services Lot 76,Cokesbury Park Tyndall Project No.: t OGAR -F0430 To Whom It May Concern: As requested by the builder, a representative of Tyndall Engineering & Design (TE &D) was on site for visually observation and analysis, the following item: • I) Determine structural adequacy of the existing (4) 2x10 girder located under the family room/laundry room wall area in regards to the cutting of the girder for plumbing access. The following conclusions and recommendation were noted: 1) Based on our visual observation and analysis, the existing (4) 2x10 girder, located under the family room/laundry room wall is adequate as constructed, to support the anticipated loading conditions. We appreciate being able to assist you during this phase of the project. If you need further assistance or require additional information please do not hesitate to contact us. Sincerely, Tyndall Engineering & Design • m1l _ter'/! p4 Melvin Cotten Pregti s., F f,P MCI I OGAR -F0430 � I/ i t r i ay 0 he ,,, tl Yy 1 Page 1 of 1 PREPARED 6/16/10, 14:09:17 INSPECTION TICKET PAGE 28 Harnett:County INSPECTOR: IVR DATE 6/17/10 ADDRESS . : 600 COKESBURY PARK LN SUBDIV: COKESBURY PARK CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : DUNCAN DEVELOPMENT LLC PHONE : PARCEL . . : 05 -0635- - -0124- -38- APPL NUMBER: 10- 50024103 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 04/01/2010 02:32 PM RDCONTE - -- 600 COKESBURY PARK / COKESBURY #76 TAKE 421 TO CHRISTIAN LIGHT ROAD TO COKESBURY ROAD. S/D ON THE RIGHT. * * *PWR CO: WAITING ON CUS * ** STRUCTURE: 000 000 57X50 CRAWL 3BD /2BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 01 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 4/27/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001916127 4/27/10 AP T /S: April 27, 2010 11:00 AM BSUTTON 3103 01 4/30/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001918241 4/30/10 AP T /S: April 30, 2010 10:42 AM BSUTTON B105 01 5/05/10 BS R *OPEN FLOOR VRU #: 001920540 5/05/10 AP T /S: May 05, 2010 11:50 AM BSUTTON A814 01 5/05/10 TW DRESS CONFIRMATION TIME: 17:00 VRU #: 001918250 4/30/10 AP 600 COKESBURY PARK LN FUQUAY VARINA 27526 T /S: 04/30/2010 09:46 AM TWARD R425 01 5/12/10 BS FOUR TRADE ROUGH IN VRU #: 001924840 5/12/10 DP 1. No baffles /firestop. 2. Beam added inceiling at end of hall, not shown on plan, no support. 3. No header over bath entry door. Inspection stopped do not side /insulate $50 re fee R425 02 5/14/10 BS FOUR TRADE ROUGH IN VRU #: 001925734 5/14/10 DA 1. Need engineers repair on girder overnotched for washing machine drain. Ok to side /insulate I129 01 5/18/10 BS R *INSULATION INSPECTION VRU #: 001927954 5/18/10 AP T /S: May 18, 2010 11:19 AM BSUTTON R425 03 5/18/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001928241 5/18/10 AP T /S: 05/17/2010 03:07 PM NTART T /S: May 18, 2010 11:19 AM BSUTTON H824 01 6/07/10 JM V'ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001937853 6/07/10 AP T /S: 06/08/2010 09:48 AM SSTEWART T /S: 06/08/2010 09:48 AM SSTEWART R429 01 6/17/10 TI FOUR TRADE FINAL VRU #: 001942063 A -r�.I Ap_L- t COMMENTS AND NOTES g79 it,/ 9 e r ty'r w,, 5f as .7.. F i ^n Em W:Imc7I + n e1 a rri 77:''': . "7 4 7 s e 4 ,,,,, T hi -;=,s, -k,„ -;; -;44k 7.* -;.,4, 7. 7,4 - 7, s 4 79 ' 41H 4..o aiaati+).,i .44) ti",,.1;1 .4iide 4A,'" 4:), ' Cou o f Harnett 1 Building In spections Department il t„, Planning Services �. Certificate of Compliance: Occupancy: >- Certificate issued pursuant to the requirements of North Carolina General Statute I53A -363 and Harnett P 9 ,, County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the .` various ordinances of the County of Hamett and the North Carolina State Building Codes. For the following: Use Classification: lc -5 Permit Numbers Name: buy, co,. OPvf tnr?1Meat Si.. , Building: in- Snn w tn - 3 Electrical: w Address: An C.obpsh L Insulation: Plumbing: 1 Mechanical: MFG Home: IS. ,,` Date: G • ) 7 - i O Building Official: lit 77 `';