Loading...
LAND USE II k,,, Harnett ✓ N T T A itrivi) Emergency Services Department Plan Review, Inspection and Permit Fees Application Number 10- 50024587 $150.00 Explosive Mat. (90 Days) $ 75.00 n Explosive Mat. (72 Hrs) $ 25.00 ❑ Fireworks Public Display $ 35.00 Z Final Inspection $ 35.00 +2.00 per device n Fire Alarm Testing $ 35.00 + 2.00 per nozzle ❑ Fixed Fire Suppression $ 25.00 1 1 Insecticide Fog /Fumigation $ 50.00 Pipe Test/UST /AGST $ 50.00 Z Plans up to 5000 ft $100.00 ❑ Plans 5001 ft to 10,000 ft $150.00 n Plans 10,001 ft to 25,000 ft $250.00 ❑ Plans 25,001 ft and over $ 35.00 + 2.00 per Head 1 Sprinkler Certification Test $ 35.00 ❑ Standpipe Testing $ 25.00 1 I Special Assembly $ 25.00 U Temporary Kiosks /Displays $ 25.00 n Tents, Canopies, Air Supported $ 50.00 ❑ Tank Installation (charge for each tank) $ 50.00 ❑ Tank Removal (charge for each tank) $ 85.00 Total Total device /heads Teddy Joe Mclamb 06/14/10 Code Enforcement Official Date IUI'I� " "' II _ „�� ., ���IP� '��������,t !�� Ha rnett � �M� Emergency Services II�� g��IIr�OTY _ 4��rllil�li ��IIIJI�iII� Dery U cnxNr. sera A ,,erthernett, @9, Y Fire Marshal Division June 14, 2010 Daren McLean P.O. Box 1029 Lillington, NC 27546 Harnett Central Middle School 2529 Harnett Central Rd Angier, NC 27521 Application Number 10- 50024587 Mr. McLean, Thank you for submitting the plans for the pod. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 1003.2.11 Means of egress illumination. o The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied o Bathrooms to have emergency lights installed. o The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits. • 906.1 Fire Extinguishers o Fire extinguishers shall be placed in approved locations as drawn by the code enforcement official on the approved plans. o The fire extinguishers provided shall have a minimum rating of 2A 5B:C and shall not be installed higher than 5 feet above the finished floor. P Ptm�� ° , 9�Va�Qarnett i :, ;', �u �,,„ 911�ti1'I�I�"' 7 1d�!Iidl N O R U A A ( Emergency Services Y Y • 404.2 Fire Safety and Evacuation Plans o An approved fire safety and evacuation plans shall be prepared and maintained for Group E occupancies. • 907.1.1 Fire Alarm Construction documents o Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. The submittal shall be stamped/sealed by a design P.E. as per previous conversations. Construction documents shall include, but not be limited to, all of the following: • A floor plan. • Locations of alarm- initiating and notification appliances. • Alarm control and trouble signaling equipment. • Annunciation. • Power connection. • Battery calculations. • Conductor type and sizes. • Voltage drop calculations. • Manufacturers, model numbers and listing information for equipment, devices and materials. • Details of ceiling height and construction. • The interface of fire safety control functions. Thank you again for submitting the plans for the pod. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, ?ea lfae wee.daw6 T.J. McLamb, CFI Chief Deputy Fire Marshal