Loading...
INSPECTIONS PREPARED 12/29/09, 13:58:32 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 12/30/09 ADDRESS . : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 2B4 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 TI , � y / R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 1)-30-01 � ✓((/ T /S: 12/29/2009 10:17 AM VBROWN COMMENTS AND NOTES PREPARED 1/07/10, 13:59:04 INSPECTION TICKET PAGE 21 Harnett County INSPECTOR: IVR DATE 1/08/10 ADDRESS . : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 234 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN A814 01 1/08/10 TI ADDRESS CONFIRMATION VRU #: 001868710 B103 01 1/08/10 TI R *BLDG FOUND & TEM SVC POLE VRU #: 001868728 /1-10 7: P4ffr COMMENTS AND NOTES PREPARED 1/12/10, 14:00:07 INSPECTION TICKET PAGE 23 Harnett County INSPECTOR: IVR DATE 1/13/10 ADDRESS . : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 2B4 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 3101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN B103 01 1/08/10 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001868728 1 /08 /10 AP t - pole passed A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868710 1/12/10 AP 951 WHISPERING PINES DR LOT 346 SPRING LAKE 28390 T /S: 01/12/2010 01:04 PM TWARD 3105 01 1/13/10 TI R *OPEN FLOOR VRU #: 001869742 / - iy - io COMMENTS AND NOTES PREPARED 2/10/10, 13:58:43 INSPECTION TICKET PAGE 17 Harneoufaty INSPECTOR: IVR DATE 2/11/10 ADDRESS . :/951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 284 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 MDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN B103 01 1/08/10 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001868728 1/08/1• AP t - pole passed A814 01 1 /08 /10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868710 1/12/10 AP 951 WHISPERING PINES DR LOT 346 SPRING LAKE 28390 T /S: 01/12/2010 01:04 PM TWARD B105 01 1/13/10 JH R *OPEN FLOOR VRU #: 001869742 1/13/10 'AP R427 01 2/11/10 � � TI FOUR TRADE ROUGH IN >2500 VRU #: 001881663 COMMENTS AND NOTES • rs HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillingt on, NC 27546 910- 893 -7525 DO NOT REMOVE DA 1E: 02 -11 -10 PERMIT # 09- 50023196 ADDRESS: 951 whispering pines. VIOLATIONS: 1. Provide floor plans ...plans incomplete 2. Bolt sill plates in garage per code 3. Install fireplace 4. Leak in drain pipe by fill riser .. in two places 5. Large 2x4 wall over rear bedroom should be laterally braced in middle of wall across to cathedral ceiling or have engineer advise other remedy 6. No insulation baffles in place Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 2/18/10, 13:58:59 INSPECTION TICKET PAGE 25 Harnett County INSPECTOR: IVR DATE 2/19/10 ADDRESS . : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 284 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 46X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN B103 01 1 /08 /10 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001868728 1/08/10 AP t -pole passed A814 01 1 /08 /10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868710 1/12/10 AP 951 WHISPERING PINES DR LOT 346 SPRING LAKE 28390 T /S: 01/12/2010 01:04 PM TWARD B105 01 1/13/10 JH R *OPEN FLOOR VRU #: 001869742 1/13/10 AP R427 01 2/11/10 FOUR TRADE ROUGH IN >2500 VRU #: 001881663 2/11/10 DA T /S: 02/11/2010 12:04 PM MREARIC T /S: 02/11/2010 12:05 PM MREARIC X. provide floor plans d'. bolt sill plates in garage per code X. install fireplace leak in drain pipe by fill riser '.. large 2x4 wall ovewr rear bedroom must be laterally braced no insulation baffles R427 02 2/ 1 /10 T� _� // OUR TRADE ROUGH IN >2500 VRU #: 001884857 7 /U!/ COMMENTS AND NOTES PREPARED 2/24/10, 14:13:16 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 2/25/10 ADDRESS . 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 284 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AN JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN 8103 01 1/08/10 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001868728 1/08/10 AP t -pole passed A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868710 1/12/10 AP 951 WHISPERING PINES DR LOT 346 - SPRING LAKE 28390 T /S: 01/12/2010 01:04 PM TWARD B105 01 1/13/10 JH R *OPEN FLOOR VRU #: 001869742 1/13/10 AP R427 01 2/11/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001881663 2/11/10 DA T /S: 02/11/2010 12:04 PM MREARIC T /S: 02/11/2010 12:05 PM MREARIC 1. provide floor plans 2. bolt sill plates in garage per code 3. install fireplace 4. leak in drain pipe by fill riser 5. large 2x4 wall ovewr rear bedroom must be laterally braced 6. no insulation baffles R427 02 2/19/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001884857 2/19/10 AP I129 01 2/25/10 TI R *INSULATION INSPECTION VRU #: 001887009 COMMENTS AND NOTES PREPARED 6/03/10, 14:18:08 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 6/04/10 t ADDRESS . : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 284 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JE R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER 8101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 8101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN B103 01 1 /08 /10 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001868728 1/08/10 AP t -pole passed A814 01 i /08 /lo TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868710 1/12/10 AP J 951 WHISPERING PINES DR LOT 346 SPRING LAKE 28390 T /S: 01/12/2010 01:04 PM TWARD B105 01 1/13/10 JH R *OPEN FLOOR VRU #: 001869742 1/13/10 AP R427 01 2/11/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001881663 2/11/10 DA T /S: 02/11/2010 12:04 PM MREARIC T /S: 02/11/2010 12:05 PM MREARIC 1. provide floor plans 2. bolt sill plates in garage per code 3. install fireplace 4. leak in drain pipe by fill riser 5. large 2x4 wall ovewr rear bedroom must be laterally braced 6. no insulation baffles R427 02 2/19/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001884857 2/19/10 AP I129 01 2/25/10 JH R *INSULATION INSPECTION VRU #: 001887009 2/25/10 AP R431 01 6/04/10 TI FOUR TRADE FINAL >2500 VRU #: 001936111 6- 'r '-in DP ° tir( 1 , COMMENTS AND NOTES r , HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DATE: 06 -04-10 PERMIT # 09- 50023196 ADDRESS: 951 whispering pines VIOLATIONS: 1. Air handler is open in attic 2. Remove all lumber under house in contact with grade 3. Install inter - system bonding terminal Fee 50.00 Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPAR &D 6, /07/10, 14:46:10 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 6/08/10 ADDRESS'. : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 2B4 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 11/04/2009 09:44 AM JBROCK - - -- ANDERSON CREEK LOT 346 HWY 27 TO NURSERY RD TRUN LEFT FOLLOW TO RAY RD TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 48X51 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 JB R *BLDG FOOTING / TEMP SVC POLE VRU #: 001864248 12/21/09 CA T /S: 12/21/2009 03:44 PM JBROCK CA PER CUSTOMER B101 02 12/29/09 VC R *BLDG FOOTING / TEMP SVC POLE VRU #: 001865823 12/29/09 CA T /S: 12/29/2009 10:16 AM VBROWN JOHN CALLED AND ASKED FOR THE INSP TO BE ROLLED OVER TO 12/30/09 B101 03 12/30/09 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001865989 12/30/09 AP T /S: 12/29/2009 10:17 AM VBROWN B103 01 1/08/10 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001868728 1/08/10 AP t -pole passed A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868710 1/12/10 AP 951 WHISPERING PINES DR LOT 346 SPRING LAKE 28390 T /S: 01/12/2010 01:04 PM TWARD 8105 01 1/13/10 JH R *OPEN FLOOR VRU #: 001869742 1/13/10 AP R427 01 2/11/10 MR FOUR TRADE ROUGH IN >2500 VRU #: 001881663 2/11/10 DA T /S: 02/11/2010 12:04 PM MREARIC T /S: 02/11/2010 12:05 PM MREARIC 1. provide floor plans 2. bolt sill plates in garage per code 3. install fireplace 4. leak in drain pipe by fill riser 5. large 2x4 wall ovewr rear bedroom must be laterally braced 6. no insulation baffles R427 02 2/19/10 JH FOUR TRADE ROUGH IN >2500 VRU #: 001884857 2/19/10 AP I129 01 2/25/10 JH R *INSULATION INSPECTION VRU #: 001887009 2/25/10 AP R431 01 6/04/10 MR FOUR TRADE FINAL >2500 VRU #: 001936111 6/04/10 DP T /S: 06/04/2010 01:32 PM MREARIC air handler in attic is open CONTINUED ONTO NEXT PAGE PREPARED 6/07/10, 14:46:10 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 6/08/10 ADDRE$9 . : 951 WHISPERING PINES DR SUBDIV: ANDERSON CREEK CLUB 2B4 CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ELMWOOD PARTNERS LLC PHONE : PARCEL . . : 01- 0535 -11- -0100- -33- APPL NUMBER: 09- 50023196 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS remove all lumber under house in contact with grade install intersyustem bonding terminal R431 02 / 6/08/10 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001937606 WV() lam' T /S: 06/07/2010 02:44 PM RDCONTE COMMENTS AND NOTES p lk :" " r . 1 i t ; -,2r v i a r f u.3 TIt , r itc::!, rvy.• &; i �'. r i , ✓,.yru. 7 i, ; ., •r +wvjf . 7. 1.' tNr "' ;yw:F • County. of Harnett Building Inspections Department Planning Services 4 Certificate of Compliance: Occupancy: X Certificate issued re ursuant to the requirements of North Carolina General Statute 1 53A-363 and Harnett P 9 County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: .eS;dCA -hc&A Permit Numbers Name: H `- H Ism sl c4vIS TN t Building: (B E b . lectrical: „ •, Address: 9C.1 WIN1s r.n, P; S br Insulation: ,er tl, Spr ; ■ � t_Jce AI C 28 4 O Plumbing: Mechanical: 0 MFG Home: Date:&if ho Building Official_,r ,e r NII 74 ,...itc ,N, Ir., M.V 'TIT, # 75 i , 4.. f t ‘ :