INSPECTIONS PREPARED 5/26/10, 14:28:11 INSPECTION TICKET PAGE - 1
Harnett 'minty
- INSPECTOR: IVR DATE 5/27/10,
ADDRESS . : 55 ENDURANCE LN _ SUBDIV: RAYNEL
CONTRACTOR : PHONE :
OWNER . . : PERRY BARBARA #8 • PHONE : (718) 774 -8721
PARCEL . . : 02 -1518- - -0068- -13-
APPL NUMBER: 05- 50013285 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : 55 ENDURANCE LANE. TAKE FAIRGROUND RD
RIGHT ON ENDURANCE LANE. LOT AT
CUL -DE -SAC. - A.DRIGGERS
STRUCTURE: 000 000 32X34 2BR IBA DEN /DINING 2STORY ADDITION
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 2.00 PROPOSED USE • ADDITION
SEPTIC - EXISTING' • YES
PERMIT: CPBP 00 CP BUILDING EMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/03/05 KS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001083972
11/03/05 AP VOICE MESSAGE LEFT
B103 01 11/15/05 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001092276
11/15/05 DA VOICE MESSAGE LEFT
8103 02 11/17/05 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001093774
11/17/05 AP VOICE MESSAGE LEFT
3105 01 11/28/05 BS R *OPEN FLOOR VRU #: 001098591
11/28/05 AP
R425 01 3/05/08 KS FOUR TRADE ROUGH IN VRU #: 001571835
3/05/08 DA 1. Electrical wiring has to many violations to list.
Recommend an electrician be hired to correct wiring.
2. No test on plumbing.
3. no plans available.
4. Fire block stairs.
5. Ductwork on ground in crawl space.
Inspection stopped.
R425 02 7/01/08 KS FOUR TRADE ROUGH IN VRU #: 001634740
7/01/08 DA 1. Need test on water drain lines and water distribution.
2. GFCI bathrooms shall be on separate 20 amp circuit.
3. Fire block between stairs stringers with 2x material.
4. Need catwalk and platform to mechanical unit in attic.
5. toilet flanges shall be installed with corrosion
resistant screws.
6. Install insulation baffles.
7. Repair notch in double to plate in upstairs bedroom.
OK to insulate.
R425 03 11/24/08 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001709260
9/25/08 AP
R429 02 5/27/10 TI FOUR TRADE FINAL VRU #: 001932938
R429 01 5/27/10 TI FOUR TRADE FINAL VRU #: 001932912
5/26/10 CA T /S: 05/26/2010 02:27 PM NTART
COMMENTS AND NOTES
w ^z '!,3-'r y :C7 t'" rr• Y d rm r: rn : c, 70c r i, ? fl.'-:V." w r yJ ¢ ' 1,e��''�'` P ,• 7g s- r _ Pr 4 ,: ,
cr
County of Harnett
" , Building; Inspections Department
Planning Services
Certificate of Compliance: Occupancy: ✓
C
I lls
ertificate issued re ursuant to the requirements of North Carolina General Statute 153A -363 and Harnett
P 9
County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the
ti various ordinances of the County of Harnett a North Carolina State Building Codes. For the (lowing: r\
Use Classification: ad *` nom -. Permit Num s
Name: s ✓✓ 6 avant Building: CV ,
Electrical: \ F y
Address: _5' +'tJct o v'o.. ce t -ri✓J ` Insulation:
ra
Plumbing: v,
M
4
echanical: - -_5
MFG Home:
Date: c-oco - 1 b Building Official: }(4___ a 9 s