Loading...
INSPECTIONS PREPARED 1/13/10, 13:59:06 INSPECTION TICKET PAGE 30 Harnett County INSPECTOR: IVR DATE 1/14/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52X62 3BDR 2BATH SFD,GAR,DCK,FIN BON RM FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED R ESULT RESULTS /COMMENTS / B101 01 1/14/10 R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 /1 id COMMENTS AND NOTES PREPARED 1/19/10, 14:01:29 INSPECTION TICKET PAGE 39 Harnett County INSPECTOR: IVR DATE 1/20/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52X62 3BDR 2BATH SFD,GAR,DCK,FIN BON RM FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1'/14/10 FS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 1/14/10 AP T /S: 01/14/2010 02:02 PM FSPIVEY A814 01 1/20/10 TI ADDRESS CONFIRMATION VRU #: 001872886 B103 01 1�/2 O?ll�00/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001872878 ' /O COMMENTS AND NOTES 7 t ,. PREPARED 1/28/10, 13:59:22 INSPECTION TICKET PAGE 25 Harnett County INSPECTOR: IVR DATE 1/29/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52X62 3BDR 2BATH SFD, GAR, DCK, FIN BON RM FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/14/10 FS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 1/14/10 AP T /S: 01/14/2010 02:02 PM FSPIVEY B103 01 1/20/10 FS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872878 1/20/10 AP T /S: 01/20/2010 02:31 PM FSPIVEY A814 01 1/20/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001872886 1/22/10 AP 179 wynngate dr lot 116 cameron 28326 �, T /S: 01/22/2010 02:28 PM TWARD P309 01 /1 1/29 f 1// R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001877703 .� r G r( „ s i ll � T /S: 01/28/2010 11:32 AM RDCONTE --'— COMMENTS AND NOTES r .47-1,4 / S r Sr/.. Le/eL « -a PREPARED 2/02/10, 13:58:39 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 2/03/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52X62 3BDR 2BATH SFD, GAR, DCK, FIN BON RM FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/14/10 FS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 1/14/10 AP T /S: 01/14/2010 02:02 PM FSPIVEY B103 01 1/20/10 FS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872878 1/20/10 AP T /S: 01/20/2010 02:31 PM FSPIVEY A814 01 1/20/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001872886 1/22/10 AP 179 wynngate dr lot 116 cameron 28326 T /S: 01/22/2010 02:28 PM TWARD P309 01 1/29/10 FS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001877703 1/29/10 DA T /S: 01/28/2010 11:32 AM RDCONTE T /S: 01/29/2010 01:51 PM FSPIVEY need water test P309 02 2/03/ ` R *PLUMB UNDER SLAB VRU #: 001878776 � Water test will be put on the day of inspection due to freezing weather conditions. Thanks. 7 .1 COMMENTS AND NOTES PREPARED 2/03/10, 13:58:02 INSPECTION TICKET PAGE 23 Harnett County INSPECTOR: IVR DATE 2/04/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52X62 3BDR 2BATH SFD,GAR,DCK,FIN BON RM FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/14/10 FS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 1/14/10 AP T /S: 01/14/2010 02:02 PM FSPIVEY B103 01 1/20/10 FS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872878 1/20/10 AP T /S: 01/20/2010 02:31 PM FSPIVEY A814 01 1/20/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001872886 1/22/10 AP 179 wynngate dr lot 116 Cameron 28326 T /S: 01/22/2010 02:28 PM TWARD P309 01 1/29/10 FS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001877703 1/29/10 DA T /S: 01/28/2010 11:32 AM RDCONTE T /S: 01/29/2010 01:51 PM FSPIVEY need water test P309 02 2/03/10 FS R *PLUMB UNDER SLAB VRU #: 001878776 2/03/10 AP Water test will be put on the day of inspection due to freezing weather conditions. Thanks. T /S: 02/03/2010 01:05 PM FSPIVEY B111 01 2 04/10 T /� R *BLDG SLAB INSP VRU #: 001879428 COMMENTS AND NOTES A1T PREPARED 3/04/10, 14:06:16 INSPECTION TICKET PAGE 20 Harnett County INSPECTOR: IVR DATE 3/05/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52X62 3BDR MATH SFD,GAR,DCK,FIN BON RM FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE . SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/14/10 FS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 1/14/10 AP T /S: 01/14/2010 02:02 PM FSPIVEY B103 01 1/20/10 FS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872878 1/20/10 AP T /S: 01/20/2010 02:31 PM FSPIVEY A814 01 1/20/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001872886 1/22/10 AP 179 wynngate dr lot 116 cameron 28326 T /S: 01/22/2010 02:28 PM TWARD P309 01 1/29/10 FS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001877703 1/29/10 DA T /S: 01/28/2010 11:32 AM RDCONTE T /S: 01/29/2010 01:51 PM FSPIVEY need water test P309 02 2/03/10 FS R *PLUMB UNDER SLAB VRU #: 001878776 2/03/10 AP Water test will be put on the day of inspection due to freezing weather conditions. Thanks. T /S: 02/03/2010 01:05 PM FSPIVEY B111 01 2/04/10 FS R *BLDG SLAB INSP VRU #: 001879428 2/04/10 AP T /S: 02/04/2010 01:32 PM FSPIVEY R427 01 3/03/10 FS FOUR TRADE ROUGH IN >2500 VRU #: 001889013 3/03/10 AP T /S: 03/03/2010 02:05 PM FSPIVEY I129 01 3/05/10 , INSPECTION VRU #: 001890821 , 1. R425 01 3/05/10 d FOUR TRADE ROUGH IN VRU #: 001890813 3/04/10 CA COMMENTS AND NOTES PREPARED 6/02/10, 14:02:46 INSPECTION TICKET PAGE 6 Hap ounty INSPECTOR: IVR DATE 6/03/10 ADDRESS . : 179 WYNNGATE DR SUBDIV: ASHEFORD 149LOTS CONTRACTOR : JASON PRICE CONST. INC PHONE : (910) 897 -8811 OWNER . . : MARY MACKS DEVELOPMENT LLC PHONE : PARCEL . . : 09- 9575 -05- -0185- -15- APPL NUMBER: 09- 50023379 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/09/2009 12:30 PM VBROWN - - -- WYNNGATE DRIVE, ASHEFORD SUB DIV #116. 27W, RIGHT ON 24, RIGHT ON MARKS RD, LEFT ON ASHEFORD WAY, RIGHT ON WYNNGATE, LOT ON LEFT. STRUCTURE: 000 000 52E62 3BDR 2BATH SFD, GAR,DCR, PIN BON RM FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 1/14/10 FS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001870586 1/14/10 AP T /S: 01/14/2010 02:02 PM FSPIVEY B103 01 1/20/10 FS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872878 1/20/10 AP T /S: 01/20/2010 02:31 PM FSPIVEY A814 01 1/20/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001872886 1/22/10 AP '1179 wynngate dr lot 116 cameron 28326 T /S: 01/22/2010 02:28 PM TWARD P309 01 1/29/10 FS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001877703 1/29/10 DA T /S: 01/28/2010 11:32 AM RDCONTE T /S: 01/29/2010 01:51 PM FSPIVEY need water test P309 02 2/03/10 FS R *PLUMB UNDER SLAB VRU #: 001878776 2/03/10 AP Water test will be put on the day of inspection due to freezing weather conditions. Thanks. T /S: 02/03/2010 01:05 PM FSPIVEY B111 01 2/04/10 FS R *BLDG SLAB INSP VRU #: 001879428 2/04/10 AP T /S: 02/04/2010 01:32 PM FSPIVEY R427 01 3/03/10 FS FOUR TRADE ROUGH IN >2500 VRU #: 001889013 3/03/10 AP T /S: 03/03/2010 02:05 PM FSPIVEY I129 01 3/05/10 FS R *INSULATION INSPECTION VRU #: 001890821 3/05/10 AP T /S: 03/05/2010 02:21 PM FSPIVEY R425 01 3/05/10 TI FOUR TRADE ROUGH IN VRU #: 001890813 3/04/10 CA / H824 01 5/12/10 OT V ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001925973 5/12/10 AP T /S: 05/13/2010 10:50 AM SSTEWART T /S: 05/13/2010 10:51 AM SSTEWART R431 01 6/03/10 I FOUR TRADE FINAL >2500 VRU #: 001935717 trire 513F0 COMMENTS AND NOTES • 1 .. n ,... yr .. :o-.. .r w• � , 1 fl s s sS Asas1Ss nS 4 • C ounty o f Harnett Building Inspections Department • PI nning Services Certificate of Compliance: Occupancy: X f, 7 ' 4 Certificate issued pursuant to the requirements of North Carolina General Statute 1 -363 and Harnett P 9 ° 'LL' County Zoning Ordinances. This "certifies at the time of issuance, this structure was in compliance with the ti' various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: r• Use Classification: ?et i r� AA -i r,, - Permit Numbers N ame: T o.son �r (�r.si`• �T r :Building: - � ! it ) Electrical: �'� >; ti A ddress: 1 %A.); ,nn t Insulation: o v i. 4 e � nsu h Cone'.re, N � Z93'2 Plumbing: �i V Mechanical: O r. .. MFG Home: i Date: aLa f(o Building Official: _� • r '''' ,,,,,e,7,4 P4 , s 7 New Itivr,77,v , ..