INSPECTIONS PREPARED 10/23/09, 7:57:04 INSPECTION TICKET PAGE
Harnett County INSPECTOR: IVR DATE 10/23/09
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 421S TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI. RIGHT ON THREE BRIDGES
RD 1.3MI. RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/21/09 , , ^ R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
(b• 09 A1.- T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
COMMENTS AND NOTES
.'
PREPARED 10/26/09, 14:00:13 INSPECTION TICKET PAGE 30
Harnett County INSPECTOR: IVR DATE 10/27/09
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS: T /S: 09/18/2009 09:14 AM VBROWN - - --
t _ MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 4215 TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
STRUCTURE: 000 000 28X32 38DR 2BATH SFD WITH DECK CRAWL
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
A814 01 10/27/09 TI ADDRESS CONFIRMATION VRU #: 001842293
B103 01 10/27/09 TI„_.o R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
COMMENTS AND NOTES " 6
-1 ,
----.---- -.471--
S Harnett "
County S� enat Notes Dls la 1 -� i }� � � ;p ' � „ G, a. - � i1 i 1P �' it l ei � r-11 „
u ,
Functpns: HSp ,
1 g 1 3 I 1 1 ing .: ' ,)'11 OR612909 41503 PM.'.
Property address`, 137 MEADOW RIDGE DR' 02 o c /'y 3
PARCEL NUMBER; ...... 024516 :0200 91 ,� , 1 CCCCJJJ�SSS 111
Miec info s r.
r Source code Note Date
RPPL BPDN T/5: 09/18/2009 09:14 AM VBROWN - - -- 9/10/09'”'
RPPL BPDN, MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV 9/18/09'
' RPPL- BPDN f126. 4215 TO DUNN, LEFT ON RED HILL 9/18/09
APPL BPDN CHURCH RD 2.3M1, RIGHT ON THREE BRIDGES 9/18/09 "ii
RPPL BPDN RD 1.3MI, RIGHT ON MEADOW LARK RD 9/1
(RPPL BPDN 0. 1M1, LEFT ON MORRISON DRIVE 0.1M1, 9/18/09"
t RPPL BPDN RIGHT ON MEADOW RIDGE DRIVE N26. 9/18/09 T, ''
RPPL BPDN T /S: 10/26/2009 04:11 PM NTART 10/26/09. d .,
APPL BPDN PREMISE p 69065576 * * * * * * * * * * * * * * * * * * ** 10/26/09 ,,::
RPPL BPMN X XXXXXX XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 9/17/09
RPPL BPMN PERMIT INCLUDES BLDG, ELEC, MECH, PLUMB 9/17/09
APPL BPMN INSULATION 0110 LAND USE. 9/17/09
APPL BPMN X XXXXXXX X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 9/17/091
a. 4:
PREPARED 10/29/09, 13:59:02 INSPECTION TICKET PAGE 31
Harnett County INSPECTOR: IVR DATE 10/30/09
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN - - --
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 421S TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
T /S: 10/26/2009 04:11 PM NTART
PREMISE # 69865576 * * * * * * * * * * * * * * * * * * **
STRUCTURE: 000 000 28X32 3BDR 2BATH SFD WITH DECK CRAWL
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY - COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B1O1 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
T /S: 10/26/2009 04:12 PM NTART
A814 01 10/27/09 TI ADDRESS CONFIRMATION VRU #: 001842293
B103 01 10/27/09 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
10/27/09 AP
B105 01 10/30/09 R *OPEN FLOOR VRU #: 001844232
•3o•t
COMMENTS AND NOTES
PREPARED 12/04/09, 13:58:51 INSPECTION TICKET PAGE 15
Harnett County INSPECTOR: IVR DATE 12/07/09
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN - - --
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 4215 TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
T /S: 10/26/2009 04:11 PM NTART
PREMISE # 69865576 * * * * * * * * * * * * * * * * * * **
STRUCTURE: 000 000 28X32 3BDR 2BATH SFD WITH DECK CRAWL
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
T /S: 10/26/2009 04:12 PM NTART
8103 01 10/27/09 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
10/27/09 AP
A814 01 10/27/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001842293
11/04/09 AP 137 MEADOW RIDGE DR
DUNN 28334
T /S: 11/04/2009 03:59 PM TWARD
8105 01 10/30/09 BS R *OPEN FLOOR VRU #: 001844232
10/30/09 AP T /S: October 30, 2009 01:24 PM BSUTTON
R425 01 12/07/09 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001858059
(L - Q A T /S: 12/04/2009 09:17 AM VBROWN
COMMENTS AND NOTES
PREPARED 12/08/09, 13:59:33 INSPECTION TICKET PAGE 19
Harnett County INSPECTOR: IVR DATE 12/09/09
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN - - --
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 421S TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
T /S: 10/26/2009 04:11 PM NTART
PREMISE # 69865576 * * * * * * * * * * * * * * * * * * **
STRUCTURE: 000 000 28X32 3BDR 2BATH SFD WITH DECK CRAWL
FLOOD ZONE FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
T /S: 10/26/2009 04:12 PM NTART
B103 01 10/27/09 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
10/27/09 AP
A814 01 10/27/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001842293
11/04/09 AP 137 MEADOW RIDGE DR
DUNN 28334
T /S: 11/04/2009 03:59 PM TWARD
B105 01 10/30/09 BS R *OPEN FLOOR VRU #: 001844232
10/30/09 AP T /S: October 30, 2009 01:24 PM BSUTTON
R425 01 12/07/09 IS$ FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001858059
12/07/09 DA T /S: 12/04/2009 09:17 AM VBROWN
1. Receptacles not installed beneath living room windsows
2. Bath vent not installed in half bath
3. Smoke detector outside master needs moving.
OK to side and insulate
T /S: 12/07/2009 01:09 PM KSLATTUM
I129 01 12/09/09 TII Q R *INSULATION INSPECTION TIME: 17:00 VRU #: 001859271
V"- 6C T /S: 12/08/2009 10:53 AM RDCONTE
INSULATION PER KEN
R425 02 12/09/09 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001859206
X 1I /� V'( � T /S: 12/08/2009 10:28 AM VBROWN
COMMENTS AND NOTES
PREPARED 5/20/10, 14:31:26 INSPECTION TICKET PAGE 5
Harnett County `, - INSPECTOR: IVR DATE 5/21/10
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN - - --
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 421S TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
T /S: 10/26/2009 04:11 PM NTART
PREMISE # 69865576 * * * * * * * * * * * * * * * * * * **
STRUCTURE: 000 000 282E32 3BDR 2BATH SFD WITH DECK CRAWL
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' - NEW SEPTIC WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
T /S: 10/26/2009 04:12 PM NTART
B103 01 10/27/09 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
10/27/09 AP
A814 01 10/27/09 TW /ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001842293
11/04/09 AP 137 MEADOW RIDGE DR
DUNN 28334
T /S: 11/04/2009 03:59 PM TWARD
8105 01 10/30/09 BS R *OPEN FLOOR VRU #: 001844232
10/30/09 AP T /S: October 30, 2009 01:24 PM BSUTTON
R425 01 12/07/09 KS FOUR TRADE ROUGH IN TIME: "17:00 VRU #: 001858059
12/07/09 DA T /S: 12/04/2009 09:17 AM VBROWN
1. Receptacles not installed beneath living room windsows
2. Bath vent not installed in half bath
3. Smoke detector outside master needs moving.
OK to side and insulate
T /S: 12/07/2009 01:09 PM KSLATTUM
1129 01 12/09/09 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001859271
12/09/09 AP T /S: 12/08/2009 10:53 AM RDCONTE
INSULATION PER KEN
R425 02 12/09/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001859206
12/09/09 AP T /S: 12/08/2009 10:28 AM VBROWN
H824 01 1/07/10 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001868470
1/07/10 DA PER JAMES MANHART NEEDS WATER LINE AND POWER LINE CHECKED
BEFORE FINAL CAN BE ISSUED. T /S: 01/07/2010
08:31 AM SSTEWART
T 01/07/2010 08:32 AM SSTEWART
H824 02 2/04/10 JM ` ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001880244
v CONTINUED ONTO NEXT PAGE
PREPARED 5/20/10, 14:31:26 INSPECTION TICKET PAGE 6
Harnett County ti INSPECTOR: IVR DATE 5/21/10
'i
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
2/04/10 AP T /S: 02/05/2010 10:37 AM SSTEWART
T /S: 02/05/2010 10:37 AM SSTEWART
R429 01 5/21/10 TI FOUR FOUR TRADE FINAL TIME: 17:00 VRU #: 001930163
- 31 - 10 cADVI4 T /S: 05/20/2010 12:04 PM JBROCK
COMMENTS AND NOTES
PREPARED 5/25/11, 14:03:39 INSPECTION TICKET PAGE 7
Harnett County i INSPECTOR: IVR DATE 5/26/10
ADDRESS . : 137 MEADOW. RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN - - --
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 4215 TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
T /S: 10/26/2009 04:11 PM NTART
PREMISE # 69865576 * * * * * * * * * * * * * * * * * * **
STRUCTURE: 000 000 287(32 3BDR 2BATH SFD WITH DECK CRAWL
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
8101 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
T /S: 10/26/2009 04:12 PM NTART
B103 01 10/27/09 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
10/27/09 AP
A814 01 10/27/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001842293
11/04/09 AP '/137 MEADOW RIDGE DR
DUNN 28334
T /S: 11/04/2009 03:59 PM TWARD
B105 01 10/30/09 BS R *OPEN FLOOR VRU #: 001844232
10/30/09 AP T /S: October 30, 2009 01:24 PM BSUTTON
R425 01 12/07/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001858059
12/07/09 DA T /S: 12/04/2009 09:17 AM VBROWN
1. Receptacles not installed beneath living room windsows
2. Bath vent not installed in half bath
3. Smoke detector outside master needs moving.
OK to side and insulate
T /S: 12/07/2009 01:09 PM KSLATTUM
I129 01 12/09/09 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001859271
12/09/09 AP T /S: 12/08/2009 10:53 AM RDCONTE
INSULATION PER KEN
R425 02 12/09/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001859206
12/09/09 AP T /S: 12/08/2009 10:28 AM VBROWN
H824 01 1/07/10 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001868470
1/07/10 DA PER JAMES MANHART NEEDS WATER LINE AND POWER LINE CHECKED
BEFORE FINAL CAN BE ISSUED. T /S: 01/07/2010
08:31 AM SSTEWART
/S: 01/07/2010 08:32 AM SSTEWART
H824 02 2/04/10 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001880244
CONTINUED ONTO NEXT PAGE
•
9REPAED 5/25/10, 14:03 :39 INSPECTION TICKET PAGE 8
Harnett County ' INSPECTOR: IVR DATE 5/26/10
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
2/04/10 AP T /S: 02/05/2010 10:37 AM SSTEWART
T /S: 02/05/2010 10:37 AM SSTEWART
R429 01 5/21/10 BS FOUR TRADE FINAL TIME: 17:00 VRU #: 001930163
5/21/10 DP T /S: 05/20/2010 12:04 PM JHROCK
1. No handrail on front stairs. 2. Plumbing vent capped on
roof. 3. Utility room on back of house shall have 6 minimum
clearance siding to grade 4. All arc fault breaker shall be
listed combination type. 5. Attic unit wired and breaker
sized for 10 kw heat, unit is marked 5 kw heat. 6.No
insulation markers in attic. 7. Handrails in stairway not
returned to wall. Inspection stopped. $50 re fee
R429 02 5/26/10 TI FOUR TRADE FINAL VRU #: 001932078
5 - ? 6 p
COMMENTS AND NOTES
' �Y"n r K. ✓
Violation Notice
Do Not Remove
Harnett County Inspection Department
102 East Front St P.O. Box 65
LiIlington, NC 27546
Phone (910) 893 -7525 Fax (910) 893 -2793
0950022873 May 26, 2010
1. Cannot have open risers on stairs
2. Need receptacle for hvac pump in crawl space
3. Need receptacle at end of peninsula
4. Side water heater storage
Ken Slattum
Code Administrator
PF{EPARED 5/26/10, 14:22:35 INSPECTION TICKET PAGE 9
Harnett County INSPECTOR: IVR DATE 5/27/10
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/18/2009 09:14 AM VBROWN - - --
MEADOW RIDGE DRIVE, MEADOWRIDGE SUB DIV
#26. 421S TO DUNN, LEFT ON RED HILL
CHURCH RD 2.3MI, RIGHT ON THREE BRIDGES
RD 1.3MI, RIGHT ON MEADOW LARK RD
0.1MI, LEFT ON MORRISON DRIVE 0.1MI,
RIGHT ON MEADOW RIDGE DRIVE #26.
T /S: 10/26/2009 04:11 PM NTART
PREMISE # 69865576 * * * * * * * * * * * * * * * * * * **
STRUCTURE: 000 000 28X32 3BDR 2BATH SFD WITH DECK CRAWL
FL00D ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY - COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 10/23/09 BS R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001841055
10/26/09 AP T /S: 10/22/2009 12:40 PM DJOHNSON
TSP ALSO
T /S: 10/22/2009 12:41 PM DJOHNSON
T /S: 10/26/2009 12:08 PM NTART
T /S: 10/26/2009 04:12 PM NTART
B103 01 10/27/09 KS R *BLDG FOUND & TEMP SVC POLE VRU #: 001842301
10/27/09 AP
A814 01 10/27/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001842293
11/04/09 AP \./137 MEADOW RIDGE DR
DUNN 28334
T /S: 11/04/2009 03:59 PM TWARD
B105 01 10/30/09 BS R *OPEN FLOOR VRU #: 001844232
10/30/09 AP T /S: October 30, 2009 01:24 PM BSUTTON
R425 01 12/07/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001858059
12/07/09 DA T /S: 12/04/2009 09:17 AM VBROWN
1. Receptacles not installed beneath living room windsows
2. Bath vent not installed in half bath
3. Smoke detector outside master needs moving.
OK to side and insulate
T /S: 12/07/2009 01:09 PM KSLATTUM
I129 01 12/09/09 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001859271
12/09/09 AP T /S: 12/08/2009 10:53 AM RDCONTE
INSULATION PER KEN
R425 02 12/09/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001859206
12/09/09 AP T /S: 12/08/2009 10:28 AM VBROWN
H824 01 1/07/10 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001868470
1/07/10 DA PER JAMES MANHART NEEDS WATER LINE AND POWER LINE CHECKED
BEFORE FINAL CAN BE ISSUED. T /S: 01/07/2010
08:31 AM SSTEWART
T /S: 01/07/2010 08:32 AM SSTEWART
H824 02 2/04/10 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001880244
CONTINUED ONTO NEXT PAGE
PREPAR$p 5/26/10, 14:22:35 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 5/27/10
ADDRESS . : 137 MEADOW RIDGE DR SUBDIV:
CONTRACTOR : BECKER WILLIAM H PHONE : (910) 263 -2700
OWNER . . : SIMPSON JOHN W PHONE : (910) 892 -3620
PARCEL . . : 02 -1518- - -0200- -11-
APPL NUMBER: 09- 50022873 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
2/04/10 AP T /S: 02/05/2010 10:37 AM SSTEWART
T /S: 02/05/2010 10:37 AM SSTEWART
R429 01 5/21/10 BS FOUR TRADE FINAL TIME: 17:00 VRU #: 001930163
5/21/10 DP T /S: 05/20/2010 12:04 PM JBROCK
1. No handrail on front stairs. 2. Plumbing vent capped on
roof. 3. Utility room on back of house shall have 6 minimum
clearance siding to grade 4. All arc fault breaker shall be
listed combination type. 5. Attic unit wired and breaker
sized for 10 kw heat, unit is marked 5 kw heat. 6.No
insulation markers in attic. 7. Handrails in stairway not
returned to wall. Inspection stopped. $50 re fee
R429 02 5/26/10 r�-q� FOUR TRADE FINAL VRU #: 001932078
5/26/10 ( f T /S: 05/26/2010 12:14 PM VBROWN
"` /// DA INSP CUSTOMER CALLED AND WANTED RESCHD FOR THURS
T /S: 05/26/2010 01:25 PM KSLATTUM
1. Cannot have open risers on stairs
2. Need receptacle for hvac pump
3. Need receptacle at end of peninsula
4. Install siding on water heater shed
R429 03 5/27/10 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 001933118
2 1 ! \j1 T /S: 05/26/2010 12:15 PM VBROWN
COMMENTS AND NOTES
s r k ;j a rs* -.+v -n . r T f k mist d" er-k tFrZ r ,Trl i ti r '
l et IS 44 ''. li'f 4s? a 4 \ 4 a &,44 Zoi \ 4 4 a
st, t
County of Harnett
Building Inspections Department
',„ Planning Services /
• Certificate of Compliance: Occupancy.
C
4
ertificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett
County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the
y various ordinances of the Count of Harnett a d tl}e 1 rth Carolina State Building Codes. For the following:
��, Use Classifi ation: Permit Numbers
Name: tA j t/ e Building: ^
r' Electrical: en"
p.• Address: C VI 444_ • ( Insulation:
v rJ Plumbing: ;%
Mechanical: Cr:
MFG Home:
pot
,d_
Date: S - 2:1- ' e Building Official: