Loading...
INSPECTIONS PREPARED 2/17/10, 14:16:57 INSPECTION TICKET PAGE 40 Harnett_County INSPECTOR: IVR DATE 2/18/10 ADDRESS_ . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 5 TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE - FLOOD ZONE X # BEDROOMS - 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 r1 2/18 G /10 TI R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 . I 4O T /S: 02/17/2010 12: PM DJOHNSON � t a/c pity 4d COMMENTS AND NOTES PREPARED 3/02/10, 9:06:43 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 3/02/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3000000 .00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 02/10 TII T � R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 f T /S: 03/02/2010 09:06 AM VBROWN COMMENTS AND NOTES PREPARED 3/03/10, 14:01:06 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 3/04/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JHROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54 1(40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 3000000.00 PROPOSED USE - SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 3/02/10 R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier ® corner of porch appears not to be on original footing. A814 01 3/03/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 T /S: 03/02/2010 09:06 AM VBROWN B103 02 3/04/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/'(I►o "0 A-\ COMMENTS AND NOTES PREPARED 3/08/10, 8:01:32 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 3/08/10 ADDRESS : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54K4O 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 3/02/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 DA T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier O corner of porch appears not to be on original footing. A814 01 3/03/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 T /S: 03/02/2010 09:06 AM VBROWN B103 02 3/04/10 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/04/10 DA 1. Where piers were not in center third of footer, and pier at porch did not have projection, an engineered repair is needed. Adding quickcrete is not sufficient. T/S:03/04/2010 10:45 AM DETAYLOR B103 03 3/08/10 TI �;I R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001891712 3o . 8 = / 4 r/G/ T /S: 03/08/2010 08:01 AM NTART '--" COMMENTS AND NOTES r • TYNDALL ENGINEERING 6 DESIGN. P.A. 69 Sliipwash Drive • Gun9r North •'919)95.9°58 March 5, 2010 he " ° " "" " "° t www.tyndallen{linect inp.coin Southern Built Homes 243 S. Bragg Blvd. P.O. Box 766 28390 Email: iwellonsl cam Reference: Engineering Services Lot 597 ills Creek Spring La , C Tyndall Project No.: 10GAR -F0194 To Whom It May Concern: As requested by the builder, a representative of Tyndall Engineering & Design (TE &D) was on site for visually observation and analysis, the following item: I) Determine the structural adequacy of the existing footing projection repair in regards to supporting the anticipated loading conditions. The following conclusions and recommendations were noted: 1) Based on our visual observations and analysis, the existing footing projection repairs were noted adequate as constructed to support the anticipated loading conditions. We appreciate the opportunity to assist you during this phase of the project. Should you need further assistance or require additional information please do not hesitate to contact us. Sincerely, Tyndall Engineering & Design .71 3 - Clarence L. Harris ! E %. • , �' CLH -F0194 Pren 1 • ,�r.. ; 113 o a f ;' Page 1 of 1 PREPARED 3/09/10,x'13:59:23 INSPECTION TICKET PAGE 45 Harnett County INSPECTOR: IVR DATE 3/10/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 3/02/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 DA T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier @ corner of porch appears not to be on original footing. A814 01 3/03/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 T /S: 03/02/2010 09:06 AM VBROWN B103 02 3/04/10 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/04/10 DA 1. Where piers were not in center third of footer, and pier at porch did not have projection, an engineered repair is needed. Adding quickcrete is not sufficient. T/S:03/04/2010 10:45 AM DETAYLOR 8103 03 3/08/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001891712 3/08/10 AP T /S: 03/08/2010 08:01 AM NTART per engineer letter B105 01 3/10/10 TI R *OPEN FLOOR VRU #: 001892571 3_/o -/p - COMMENTS AND NOTES PREPARED 3/31/10, 13:58:33 INSPECTION TICKET PAGE 37 Harnett County INSPECTOR: IVR DATE 4/01/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t-pole passed B103 01 3/02/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 DA T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier @ corner-of porch appears not to be on original footing. A814 01 3/03/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 3/10/10 AP T /S: 03/02/2010 09:06 AM VBROWN 31 CRAVEN CT LOT 597 SPRING LAKE 28390 T /S: 03/10/2010 01:26 PM TWARD B103 02 3/04/10 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/04/10 DA 1. Where piers were not in center third of footer, and pier at porch did not have projection, an engineered repair is needed. Adding quickcrete is not sufficient. T/S:03/04/2010 10:45 AM DETAYLOR B103 03 3/08/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001891712 3/08/10 AP T /S: 03/08/2010 08:01 AM NTART per engineer letter 3105 01 3/10/10 JH R *OPEN FLOOR VRU #: 001892571 3/10/10 AP R425 01 4/01/10 TI FOUR TRADE ROUGH IN VRU #: 001902908 COMMENTS AND NOTES PREPARED 4/05/10, 13:58:28 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 4/06/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 3/02/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 DA T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier @ corner of porch appears not to be on original footing. A814 01 3/03/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 3/10/10 AP T /S: 03/02/2010 09:06 AM VBROWN 31 CRAVEN CT LOT 597 SPRING LAKE 28390 T /S: 03/10/2010 01:26 PM TWARD B103 02 3/04/10 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/04/10 DA 1. Where piers were not in center third of footer, and pier at porch did not have projection, an engineered repair is needed. Adding quickcrete is not sufficient. T/S:03/04/2010 10:45 AM DETAYLOR B103 03 3/08/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001891712 3/08/10 AP T /S: 03/08/2010 08:01 AM NTART per engineer letter B105 01 3/10/10 JH R *OPEN FLOOR VRU #: 001892571 3/10/10 AP R425 01 4/01/10 JH FOUR TRADE ROUGH IN VRU #: 001902908 4/01/10 AP I129 01 4/06/10 TI R *INSULATION INSPECTION VRU #: 001905175 COMMENTS AND NOTES PREPARED 4/07/10, 13:59:47 INSPECTION TICKET PAGE 36 Harnett County INSPECTOR: IVR DATE 4/08/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276 OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 210 S TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 3/02/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 DA T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier @ corner of porch appears not to be on original footing. A814 01 3/03/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 3/10/10 AP T /S: 03/02/2010 09:06 AM VBROWN 31 CRAVEN CT LOT 597 SPRING LAKE 28390 T /S: 03/10/2010 01:26 PM TWARD B103 02 3/04/10 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/04/10 DA 1. Where piers were not in center third of footer, and pier at porch did not have projection, an engineered repair is needed. Adding quickcrete is not sufficient. T/S:03/04/2010 10:45 AM DETAYLOR B103 03 3/08/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001891712 3/08/10 AP T /S: 03/08/2010 08:01 AM NTART per engineer letter B105 01 3/10/10 JH R *OPEN FLOOR VRU #: 001892571 3/10/10 AP R425 01 4/01/10 JH FOUR TRADE ROUGH IN VRU #: 001902908 4/01/10 AP I129 01 4/06/10 JH R *INSULATION INSPECTION VRU #: 001905175 4/06/10 DA Need to insulate complete platform in master bedroom 1129 02 4./08/10 TI R *INSULATION INSPECTION VRU #: 001905932 11 0 J— COMMENTS AND NOTES PICh'pARED 5/25/10, 14:03:39 INSPECTION TICKET PAGE 17 Harnett County INSPECTOR: IVR DATE 5/26/10 ADDRESS . : 31 CRAVEN CT SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : SOUTHERN BUILT HOMES LLC PHONE : (910) 263 -0276. OWNER . . : SOUTHERN BUILT HOMES LLC #597 PHONE : PARCEL . . : 01- 0514 -03- -0006- -87- APPL NUMBER: 10- 50023735 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 02/04/2010 11:44 AM JBROCK - - -- 2105 TO RAY RD TO OVERHILLS RD TO OVERHILLS CREEK S/D LOT 597 STRUCTURE: 000 000 54X40 3BDR CRAWL W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE - SFD SEPTIC - EXISTING? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/18/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001884592 2/18/10 AP T /S: 02/17/2010 12:54 PM DJOHNSON t -pole passed B103 01 3/02/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001889583 3/02/10 DA T /S: 03/02/2010 09:06 AM VBROWN Center of piers are not in the center one third of the footing on 4 piers and are marked on plans with red pen, pier Q corner of porch appears not to be on original footing. A814 01 3/03/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001889575 3/10/10 AP T /S: 03/02/2010 09:06 AM VBROWN 31 CRAVEN CT LOT 597 SPRING LAKE 28390 T /S: 03/10/2010 01:26 PM TWARD B103 02 3/04/10 DT R *BLDG FOUND & TEMP SVC POLE VRU #: 001889656 3/04/10 DA 1. Where piers were not in center third of footer, and pier at porch did not have projection, an engineered repair is needed. Adding quickcrete is not sufficient. T/S:03/04/2010 10:45 AM DETAYLOR B103 03 3/08/10 JH R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001891712 3/08/10 AP T /S: 03/08/2010 08:01 AM NTART per engineer letter B105 01 3/10/10 JH R *OPEN FLOOR VRU #: 001892571 3/10/10 AP R425 01 4/01/10 JH FOUR TRADE ROUGH IN VRU #: 001902908 4/01/10 AP I129 01 4/06/10 JH R *INSULATION INSPECTION VRU #: 001905175 4/06/10 DA Need to insulate complete platform in master bedroom I129 02 4/08/10 BS R *INSULATION INSPECTION VRU #: 001905932 4/08/10 AP T /S: April 08, 2010 11:22 AM BSUTTON R429 01 5/26/10 TI FOUR TRADE FINAL VRU #: 001932037 5-2C-I0 A PB COMMENTS AND NOTES A: dt'S ae7, 2 'Wy M v 'YC+y : d" 'y ra x i ti11x r v7r4 q Ft Ink t ',y i a . i Sh ,Sitah ' . ' ' .‘ . ' . * County of Harnett <. ' BuildingiInspections Depar ' ; i. Planning S ervices Certificate of Compliance: Occupancy: ,/ Certificate issued re utsuant to the requirements of North Carolina General Statute 153A -363 and Harnett • p 9 County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: SL Permit Numbers 4 Name:5 1A /iPi ,$ ji/ &MPS Z/C Building: ,, Electrical: M�, Address: 3/ C vi ,i e, (/ Insulation: 1 Plumbing: Mechanical: o MFG Home: Date: s, ;(_ � Building OfficialA": �t