Loading...
FM REVIEW fniZ Harnett touarr A'' E Department kpRiet ih Rp_i NR wMw.harnottorg Plan Review, Inspection and Permit Fees Application Number 10- 50024493 $150.00 n Explosive Mat. (90 Days) $ 75.00 n Explosive Mat. (72 Hrs) $ 25.00 ❑ Fireworks Public Display $ 35.00 ® Final Inspection $ 35.00 +2.00 per device I I Fire Alarm Testing $ 35.00 + 2.00 per nozzle ❑ Fixed Fire Suppression $ 25.00 n Insecticide Fog/Fumigation $ 50.00 ❑ Pipe Test/UST /AGST $ 50.00 ® Plans up to 5000 ft $100.00 n Plans 5001 ft to 10,000 ft $150.00 n Plans 10,001 ft2 to 25,000 ft $250.00 n Plans 25,001 ft and over $ 35.00 + 2.00 per Head n Sprinkler Certification Test $ 35.00 n Standpipe Testing $ 25.00 ❑ Special Assembly $ 25.00 7 Temporary Kiosks/Displays $ 25.00 7 Tents, Canopies, Air Supported $ 50.00 n Tank Installation (charge for each tank) $ 50.00 ❑ Tank Removal (charge for each tank) $ 85.00 Total n/a Total device/heads Michael L. Martin 6/9/10 Code Enforcement Official Date • • „ • • ' ; • .• . . • , ' • . . J 44. • , i H arnett eitga t o u a t r OF 10 Em•ncricy union Department roAS, cnac:sNn wvnaarnattorg Y June 9, 2010 Linda and Ervin Monroe 7084 NC 210 South Bunnlevel, NC 28323 Family Center 7084 NC 210 South Bunnlevel, NC 28323 Application Number 10- 50024493 Mr. Monroe, Thank you for submitting the plans for the family center. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 906.1 Fire Extinguishers o Fire extinguishers shall be placed in approved locations as drawn by the code enforcement official on the approved plans. o The fire extinguishers provided shall have a minimum rating of 2A 10B:C and shall not be installed higher than 5 feet above the finished floor • 506.1 Knox Box o A secure key box shall be installed on the new building that houses all keys to all the doors within the building in which the fire department would need access to in the event of an emergency. o Knox Box ID stickers shall be placed on all exterior doors in which entry to the building may be gained. o The box shall be mounted not to exceed 48 — 60 inches in height. o An authorized order form is included with this letter. • • • • . H arnett { O U w T Y � mory �� � E se, ,;m, wwrharn• oop.rctt.mg mo•� .vm e,5:9 _- a NORTri CAROL ?NA •0 • 505.1 Physical Address o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and/or parking lot. o The numbers used to make up the physical address shall be at least 5 inches in height • 503.1.1 Fire Department Access o The fire department access shall extend to within 150 feet of all portions of the facility. o The fire department access road shall be of an unobstructed width of not less than 20 feet and shall have an unobstructed vertical clearance of not less the 13 feet 6 inches. o 2403.12.7 Means of egress illumination. • Means of egress shall be illuminated with light having an intensity of not less than 1 foot -candle (11 lux) at floor level while the structure is occupied. Fixtures required for means of egress illumination shall be supplied from a separate circuit or source of power. • EXIT/Emergency Lighting shall be installed as drawn on the plans by the fire code official. • Exterior Egress Lighting shall be installed as indicated on the plans. Thank you again for submitting the plans for the family center. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Again, thank you and we look forward to working with you during the construction period! Thank You, Mich 1 L. Martin Deputy Fire Marshal 2. ..;, ?;ir /. 3,. . • .