Loading...
INSPECTIONS PREPARED 8/12/09, 14:00:21 INSPECTION TICKET PAGE 20 Harnett County INSPECTOR: IVR DATE 8/13/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG, ELEC,MECH, PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 MDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 B/13/09 T R *PLUMB UNDER SLAB VRU #: 001808088 COMMENTS AND NOTES PREPARED 8/20/09, 14:00:31 INSPECTION TICKET PAGE 20 Harnett County INSPECTOR: IVR DATE 8/21/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG,ELEC,MECH, PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the . STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC B101 01 8 21/09 T R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8111 01 8/ /09 TI R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 U T /S: 08/19/2009 02:21 PM NTART COMMENTS AND NOTES PREPARED 8/28/09, 14:03:31 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 8/31/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG, ELEC, MECH, PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC B101 01 8/21/09 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8/21/09 DP All portions of the footing shall be 12 inches below grade. All portions of the exterior siding shall be 6 inches above grade. Do not pour. Dig out all footing sections to 12 inches below existing grade T /S: 08/21/2009 01:53 PM NTART B111 01 8/21/09 - R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 8/21/09 DP T /S: 08/19/2009 02:21 PM NTART T /S: 08/21/2009 01:04 PM DJOHNSON DISAPPROVED PER BRAD T /S: 08/21/2009 01:06 PM DJOHNSON T /S: 08/21/2009 01:53 PM NTART B101 02 8/24/09 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001812452 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART 8111 02 8/24/09 DT R *BLDG SLAB INSP TIME: 17:00 VRU #: 001812460 8/24/09 CA T /S: 08/21/2009 02 :09 PM NTART T /S: 08/24/2009 07:56 AM DETAYLOR B111 03 8/25/09 TI R *BLDG SLAB INSP VRU #: 001812882 8/25/09 CA T /S: 08/25/2009 10:50 AM NTART CANCELLED PER JIMMY AND CONCRETE CONTRACTOR. B111 04 3/ 819 T ci R*BLDG SLAB INSP VRU #: 001815000 COMMENTS AND NOTES PZEPARFD 10/06/09, 13:58:58 INSPECTION TICKET PAGE 21 Harnett County INSPECTOR: IVR DATE 10/07/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG,ELEC,MECH,PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC 8101 01 8/21/09 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8/21/09 DP All portions of the footing shall be 12 inches below grade. All portions of the exterior siding shall be 6 inches above grade. Do not pour. Dig out all footing sections to 12 inches below existing grade T /S: 08/21/2009 01:53 PM NTART B111 01 8/21/09 BS R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 8/21/09 DP T /S: 08/19/2009 02:21 PM NTART T /S: 08/21/2009 01:04 PM DJOHNSON DISAPPROVED PER BRAD T /S: 08/21/2009 01:06 PM DJOHNSON T /S: 08/21/2009 01:53 PM NTART B101 02 8/24/09 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001812452 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART B111 02 8/24/09 DT R *BLDG SLAB INSP TIME: 17:00 VRU #: 001812460 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART T /S: 08/24/2009 07:56 AM DETAYLOR B111 03 8/25/09 TI R *BLDG SLAB INSP VRU #: 001812882 8/25/09 CA T /S: 08/25/2009 10:50 AM NTART CANCELLED PER JIMMY AND CONCRETE CONTRACTOR. B111 04 8/31/09 DT R *BLDG SLAB INSP VRU #: 001815000 8/31/09 AP R427 01 10/07/09 v , FOUR TRADE ROUGH IN >2500 VRU #: 001832278 1 J COMMENTS AND NOTES • Violation Notice Do Not Remove Harnett County Inspection Department Jimmy Hall (910)984 -4768 Permit #09- 50022242 Date: 10/07/09 1) Fire caulk hole in top plate over dryer. 2) Bath exhaust fans need to be turned around so that duct work is not more than a 90 degree turn. 3) Fire caulk 12/2 wire @ top plate in kitchen @ closet. 4) Missing receptacle @ back door wall over 24 ". 5) Fire cracks in osb over fire place. 6) Fire caulk wire right of window @ front door in top plate 7) 3' head of water on drain lines. 8) Roof truss don't match roof truss layout. PREPARED 10/08/09, 14:08:51 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 10/09/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR ELK;i2IDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM - DEVELOPMENT INC PHONE : PARCEL . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 401S TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG,ELEC,MECH,PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC B101 01 8/21/09 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8/21/09 DP All portions of the footing shall be 12 inches below grade. All portions of the exterior siding shall be 6 inches above grade. Do not pour. Dig out all footing sections to 12 inches below existing grade T /S: 08/21/2009 01:53 PM NTART 3111 01 8/21/09 BS R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 8/21/09 DP T /S: 08/19/2009 02:21 PM NTART T /S: 08/21/2009 01:04 PM DJOHNSON DISAPPROVED PER BRAD T /S: 08/21/2009 01:06 PM DJOHNSON T /S: 08/21/2009 01:53 PM NTART B101 02 8/24/09 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001812452 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART B111 02 8/24/09 DT R *BLDG SLAB INSP TIME: 17:00 VRU #: 001812460 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART T /S: 08/24/2009 07:56 AM DETAYLOR 3111 03 8/25/09 TI R *BLDG SLAB INSP VRU #: 001812882 8/25/09 CA T /S: 08/25/2009 10:50 AM NTART CANCELLED PER JIMMY AND CONCRETE CONTRACTOR. 3111 04 8/31/09 DT R *BLDG SLAB INSP VRU #: 001815000 8/31/09 AP R427 01 10/07/09 ` F OT R TRADE ROUGH IN >2500 VRU #: 001832278 10/07/09 0 16Fire caulk hole in top plate over dryer. 203ath exhaust fans need to be turned around so that duct CONTINUED ONTO NEXT PAGE PREPARED 10/08/09, 14:08:51 INSPECTION TICKET PAGE 20 Harnett County INSPECTOR: IVR DATE 10/09/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK,RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM IJEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) REQUESTED - INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS work is not more than 90 dgrees turn. 41 V - Fire caulk 12/2 wire ® top plate in kitchen ® closet. Missing raceptacle © back door wall over 24 ". Fire caulk cracks in osb over fire place. x 9'Fire caulk wire right of window © front door in top plate. 3' head of water on drain lines. fi Roof truss dont match roof truss layout. R427 02 10/09/09 T FOUR TRADE ROUGH IN >2500 VRU #: 001833722 ,V -1- 4. d, COMMENTS AND NOTES Jett 10/13/09, 14:02:03 INSPECTION TICKET PAGE 14 �lett County INSPECTOR: IVR DATE 10/14/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIRGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : AM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : HPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS ; . T /S: 06/04/20∎'9 04:03 PM VH - - -- XX XXXXX . XXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG,ELEC,MECH,PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC B101 01 8/21/09 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8/21/09 DP All portions of the footing shall be 12 inches below grade. All portions of the exterior siding shall be 6 inches above grade. Do not pour. Dig out all footing sections to 12 inches below existing grade T /S: 08/21/2009 01:53 PM NTART B111 01 8/21/09 BS R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 8/21/09 DP T /S: 08/19/2009 02:21 PM NTART T /S: 08/21/2009 01:04 PM DJOHNSON DISAPPROVED PER BRAD T /S: 08/21/2009 01:06 PM DJOHNSON T /S: 08/21/2009 01:53 PM NTART B101 02 8/24/09 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001812452 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART B111 02 8/24/09 DT R *BLDG SLAB INSP TIME: 17:00 VRU #: 001812460 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART T /S: 08/24/2009 07:56 AM DETAYLOR B111 03 8/25/09 TI R *BLDG SLAB INSP VRU #: 001812882 8/25/09 CA T /S: 08/25/2009 10:50 AM NTART CANCELLED PER JIMMY AND CONCRETE CONTRACTOR. B111 04 8/31/09 DT R *BLDG SLAB INSP VRU #: 001815000 8/31/09 AP R427 01 10/07/09 JH FOUR TRADE ROUGH IN >2500 VRU #: 001832278 10/07/09 DA 1)Fire caulk hole in top plate over dryer. 2)Bath exhaust fans need to be turned around so that duct CONTINUED ONTO NEXT PAGE PREPARED 10/13/09, 14:02:03 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR DATE 10/14/09 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RI4GE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . . RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS work is not more than 90 dgrees turn. 3)Fire caulk 12/2 wire @ top plate in kitchen @ closet. 4)Missing receptacle @ back door wall over 24 ". 5)Fire caulk cracks in osb over fire place. 6)Fire caulk wire right of window @ front door in top plate. 7)3' head of water on drain lines. 8)Roof truss dont match roof truss layout. R427 02 10/09/09 JH FOUR TRADE ROUGH IN >2500 VRU #: 001833722 10/09/09 AP I129 01 10/14/09 TI R *INSULATION INSPECTION VRU #: 001836063 it COMMENTS AND NOTES PREPARED 5/17/10, 14:34:39 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 5/18/10 y l ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG,ELEC,MECH,PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC B101 01 8/21/09 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8/21/09 DP All portions of the footing shall be 12 inches below grade. All portions of the exterior siding shall be 6 inches above grade. Do not pour. Dig out all footing sections to 12 inches below existing grade T /S: 08/21/2009 01:53 PM NTART B111 01 8/21/09 BS R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 8/21/09 DP T /S: 08/19/2009 02:21 PM NTART T /S: 08/21/2009 01:04 PM DJOHNSON DISAPPROVED PER BRAD T /S: 08/21/2009 01:06 PM DJOHNSON T /S: 08/21/2009 01:53 PM NTART B101 02 8/24/09 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001812452 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART B111 02 8/24/09 DT R *BLDG SLAB INSP TIME: 17:00 VRU #: 001812460 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART T /S: 08/24/2009 07:56 AM DETAYLOR 8111 03 8/25/09 TI R *BLDG SLAB INSP VRU #: 001812882 8/25/09 CA T /S: 08/25/2009 10:50 AM NTART CANCELLED PER JIMMY AND CONCRETE CONTRACTOR. B111 04 8/31/09 DT R *BLDG SLAB INSP VRU #: 001815000 8/31/09 AP R427 01 10/07/09 JH FOUR TRADE ROUGH IN >2500 VRU #: 001832278 10/07/09 DA 1)Fire caulk hole in top plate over dryer. 2)Bath exhaust fans need to be turned around so that duct CONTINUED ONTO NEXT PAGE PREPARED 5/17/10, 14:34:39 INSPECTION TICKET PAGE 13 Harnett County ` INSPECTOR: IVR DATE 5/18/10 1 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS work is not more than 90 dgrees turn. 3)Fire caulk 12/2 wire @ top plate in kitchen @ closet. 4)Missing raceptacle @ back door wall over 24 ". 5)Fire caulk cracks in osb over fire place. 6)Fire caulk wire right of window @ front door in top plate. 7)3' head of water on drain lines. 8)Roof truss dont match roof truss layout. R427 02 10/09/09 JH FOUR TRADE ROUGH IN >2500 VRU #: 001833722 10/09/09 AP I129 01 10/14/09 KS R *INSULATION INSPECTION VRU #: 001836063 10/14/09 AP / H824 01 11/02/09 OT ./ ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001845692 11/02/09 AP T /S: 11/03/2009 11:37 AM SSTEWART T /S: 11/03/2009 11:37 AM SSTEWART A814 01 5/06/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001921360 5/06/10 AP T /S: 05/05/2010 01:22 PM NTART V439 CAROLINA LAKS CIR LOT 57 LINDEN 2832613 AM TWARD T /S: 05/06/2010 10:13 AM TWARD R431 01 5 18/10 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001927888 T /S: 05/17/2010 11:29 AM NTART COMMENTS AND NOTES iS EPARED 5/19/10, 13:56:47 INSPECTION TICKET PAGE 16 Harnett County i INSPECTOR: IVR DATE 5/20/10 ADDRESS 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) APPL NOTES : BPMN 6/04/09 CAROLINA OAKS CIRCLE CAROLINA OAKS SUB D IV #57 4015 TO ELLIOTT BERIVE TO WIL LU CAS RD. T /S: 06/04/2009 04:03 PM VBROWN - - -- XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX PERMIT INCLUDES BLDG, ELEC, MECH, PLUMB INSULATION AND LAND USE. XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Work must conform and comply with the STATE BUILDING CODE and all other State and local laws, ordinances & regulations STRUCTURE: 000 000 50X62 4 BDR 2BATH WITH GAR SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 8/13/09 DT R *PLUMB UNDER SLAB VRU #: 001808088 8/13/09 DA No water in stand pipe. T /S: 08/13/2009 11:58 AM DETAYLOR P309 02 8/17/09 MR R *PLUMB UNDER SLAB VRU #: 001809383 8/17/09 AP T /S: 08/17/2009 11:35 AM MREARIC B101 01 8/21/09 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001811397 8/21/09 DP All portions of the footing shall be 12 inches below grade. All portions of the exterior siding shall be 6 inches above grade. Do not pour. Dig out all footing sections to 12 inches below existing grade T /S: 08/21/2009 01:53 PM NTART B111 01 8/21/09 BS R *BLDG SLAB INSP TIME: 17:00 VRU #: 001811405 8/21/09 DP T /S: 08/19/2009 02:21 PM NTART T /S: 08/21/2009 01:04 PM DJOHNSON DISAPPROVED PER BRAD T /S: 08/21/2009 01:06 PM DJOHNSON T /S: 08/21/2009 01:53 PM NTART 8101 02 8/24/09 DT R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001812452 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART B111 02 8/24/09 DT R *BLDG SLAB INSP TIME: 17:00 VRU #: 001812460 8/24/09 CA T /S: 08/21/2009 02:09 PM NTART T /S: 08/24/2009 07:56 AM DETAYLOR B111 03 8/25/09 TI R *BLDG SLAB INSP VRU #: 001812882 8/25/09 CA T /S: 08/25/2009 10:50 AM NTART CANCELLED PER JIMMY AND CONCRETE CONTRACTOR. B111 04 8/31/09 DT R *BLDG SLAB INSP VRU #: 001815000 8/31/09 AP R427 01 10/07/09 JH FOUR TRADE ROUGH IN >2500 VRU #: 001832278 10/07/09 DA 1)Fire caulk hole in top plate over dryer. 2)Bath exhaust fans need to be turned around so that duct CONTINUED ONTO NEXT PAGE • PREPARED 5/19/10, 13:56:47 INSPECTION TICKET PAGE 17 Harnett County INSPECTOR: IVR DATE 5/20/10 ADDRESS . : 439 CAROLINA OAKS CIR SUBDIV: CAROLINA OAKS 64 LOTS CONTRACTOR : ELK RIDGE AT SOUTHVIEW LLC PHONE : (910) 323 -4393 OWNER . . : RAM DEVELOPMENT INC PHONE : PARCEL . . : 01 -0544- - -0012- -57- APPL NUMBER: 09- 50022242 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS work is not more than 90 dgrees turn. 3)Fire caulk 12/2 wire @ top plate in kitchen @ closet. 4)Missing receptacle @ back door wall over 24 ". 5)Fire caulk cracks in osb over fire place. 6)Fire caulk wire right of window @ front door in top plate. 7)3' head of water on drain lines. 8)Roof truss dont match roof truss layout. R427 02 10/09/09 JH FOUR TRADE ROUGH IN >2500 VRU #: 001833722 10/09/09 AP I129 01 10/14/09 KS R•INSULATION INSPECTION VRU #: 001836063 10/14/09 AP H824 01 11/02/09 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001845692 11/02/09 AP T /S: 11/03/2009 11:37 AM SSTEWART T /S: 11/03/2009 11:37 AM SSTEWART A814 01 5/06/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001921360 5/06/10 AP T /S: 05/05/2010 01:22 PM NTART 439 CAROLINA LAKS CIR LOT 57 LINDEN 2832613 AM TWARD T /S: 05/06/2010 10:13 AM TWARD R431 01 5/18/10 0 FOUR TRADE FINAL >2500 TIME: 17:00 VRU #: 001927888 5/18/10 T /S: 05/17/2010 11:29 AM NTART x)Need R38 insulation in attic per code. g)Stove receptacle needs to be fastened in place, $)Untreated wood on outside of house needs to be 8" from ground. *Need 2 grounding rods at least 6' apart. 5fMissing grounding bar @ outside panel for cable & phone. R431 02 5/19/10 DT FOUR TRADE FINAL >2500 VRU #: 001928506 5/19/10 CA R429 01 i 20/10 ;VOL FOUR TRADE FINAL VRU #: 001929520 COMMENTS AND NOTES r :p x: t -e % i 7 e1 : . eR+; 4. °4;rt v^n c ... ti r e wr }P 'T i 4 t v, '.. r ' . c,41,4441;4411114: 1: Mt Apt, tt As v s e t i (i7.,lig.adaVAls'a Asa Ai 1,1 Aiia A .. County of Harnett .. Building. Inspections Department �' • Planning Service Certificate of Compll annce: Occupancy: .I Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett ry County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the 0.4 f various ordinances of the Cou t Harnett and the North Carolina State Building Codes. For the following: v. , Use Classification: Permit Numbers /l Name: / • b)< (far (a ki0/h's Building: ':. Electrical: �� 1",' tp Address: 0 �Ql l �,lD��p Qi Cr t` I r a Plumbing: o 4,, i Mechanical: N '1 MFG Home: 1 Date: 51) U . i9 Building Official: 7 �, •