INSPECTIONS PREPARED 4/15/10, 13:59:20 INSPECTION TICKET PAGE 44
Harnett County INSPECTOR: IVR DATE 4/16/10
ADDRESS . : 193 BOLTON RD SUBDIV:
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073
OWNER . . : CAMPBELL UNIVERSITY PHONE : (910) 893 -4111
PARCEL . . : 11 -0660- - -0191- -02-
APPL NUMBER: 10- 50023976 CP NEW COMMERCIAL BLDG /ENTERPRISE
DIRECTIONS : T /S: 03/15/2010 04:24 PM RDCONTE - --
73 GREGORY ROAD / CAMPBELL TRAINING BLD
TAKE HWY 421S. T/L ON LESLIE CAMPBELL.
T/L ON MAIN STREET. T/R ON BOLTON DRIVE
STORAGE BUILDING WILL BE LOCATED NEXT
TO 193 BOLTON (BESIDE BASEBALL FIELD)
LAND NOTES : LXMN 9/07/06 PARCELS
1106700012 ,110680010501,110670049003,110
6700107, 1106700108 ,1106700113,1106700050
4, 1106700027 ,110670011802,110670011801,1
106700118,1106700098,1106700061 WERE
DELETED AND COMBINED WITH THIS PARCEL
TJONES
STRUCTURE: 000 000 30X30 STORAGE BLDG FOR BASEBALL FIELD
FLOOD ZONE FLOOD ZONE X
PROPOSED USE • STORAGE SEPTIC - EXISTING? • SEWER
PERMIT: CBCO 00 CP BUILDING COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
C151 01 X1/16/10 C *BLDG FOOTING VRU #: 001910935
9 I
C159 01 /4 16/10 TI C *BLDG SLAB INSP VRU #: 001910944
(CV COMMENTS AND NOTES
PREPARED 4/16/10, 13:58:14 INSPECTION TICKET PAGE 40
Harnett County INSPECTOR: IVR DATE 4/19/10
ADDRESS . : 193 BOLTON RD SUBDIV:
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073
OWNER . . : CAMPBELL UNIVERSITY PHONE : (910) 893 -4111
PARCEL . . : 11 -0660- - -0191- -02-
APPL NUMBER: 10- 50023976 CP NEW COMMERCIAL BLDG /ENTERPRISE
DIRECTIONS : T /S: 03/15/2010 04:24 PM RDCONTE - --
73 GREGORY ROAD / CAMPBELL TRAINING BLD
TAKE HWY 421S. T/L ON LESLIE CAMPBELL.
T/L ON MAIN STREET. T/R ON BOLTON DRIVE
STORAGE BUILDING WILL BE LOCATED NEXT
TO 193 BOLTON (BESIDE BASEBALL FIELD)
LAND NOTES : LXMN 9/07/06 PARCELS
1106700012 ,110680010501,110670049003,110
6700107, 1106700108 ,1106700113,1106700050
4, 1106700027 ,110670011802,110670011801,1
106700118,1106700098,1106700061 WERE
DELETED AND COMBINED WITH THIS PARCEL
TJONES
STRUCTURE: 000 000 30X30 STORAGE BLDG FOR BASEBALL FIELD
FLOOD ZONE • FLOOD ZONE X
PROPOSED USE STORAGE SEPTIC - EXISTING' • SEWER
PERMIT: CBCO 00 CP BUILDING COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
C151 01 4/16/10 KS C *BLDG FOOTING VRU #: 001910935
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C159 01 4/16/10 KS C *BLDG SLAB INSP VRU #: 001910944
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C151 02 tj 4/19 10 '�I Q C *BLDG FOOTING VRU #: 001912149
t -
C159 02 4/19/10 TI C *BLDG SLAB INSP VRU #: 001912158
4 - fI
COMMENTS AND NOTES
MT3+ T4itRStE :Ea— :latitttRUINKEIllii tedii +8[fla 1
FApr..16 2010 1:38PM D. 3379 P. I
� A ' 1 ' YNDALL
� ENGINEERING &DESIGN. P.A.
♦ 9'9 775.11D I • w 10 777.•055
69 Shipwul Drh • Garn.r . Ca.ohne • 27$29
.....,y earl* rain npd ng,cc n.
April 16, 2010
Attn.: Todd
Ph: 919 - 369 -7955
Fax: 919 - 639 -8841
Bradley Built
466 Stencil Road
Angier, NC 27501
Re.: Framing Issues
Plan:, 30x30 PEKES
Project No.: 10GAR -R0102
To Whom It May Concern
A representative of Tyndall Engineering & Design analyzed framing items for the above
referenced project Specifically, the following items listed were analyzed:
1) Rebar size and spacing for reinforced footings.
The following conclusions and recommendations were presented for the above -
mentioned items:
1) Rased on our plan review and analysis, please see the below table for the converted size
and spacing of the required reinforcements for the plan specified concrete footings.
These framing changes will adequately support the anticipated loading conditions.
FOOTING SCHEDULE
MARK SIZE PLAN SPEC. NEW
REINFORCEMENT REINFORCEMENT
A 3'- 0 "x3'- 0 "x1' -6" DP 4 — #5 E.W. 6 — #4 E.W.
B 4'- 0 "x4' -0 "x1'4" DP 5 - #5 E.W. 8 — 44 E.W.
C 6 6 "x6'- 6 "x1' -6^ DP 8 — #5 E.W. 12 —44 E.W.
We appreciate being able to assist you during this phase of the project. If you need
further assistance or require additional information please do not hesitate to contact us.
Sincerely,
Tyndall Engineering & Design
06) uree 4iaJ
Laura Grater, E.1. s o ' CAR04 %,
10GAR -R0102 q :r `'f 444
' may • e •, l a . • P V �� :
Page 1 of 1 ��� t0' ' - - Tiv cilit,
PREPARED 4/29/10, 13:58:27 INSPECTION TICKET PAGE 36
Harnett County INSPECTOR: IVR DATE 4/30/10
ADDRESS . : 193 BOLTON RD SUBDIV:
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073
OWNER . . : CAMPBELL UNIVERSITY PHONE : (910) 893 -4111
.PARCEL . . : 11 -0660- - -0191- -02-
APPL NUMBER: 10- 50023976 CP NEW COMMERCIAL BLDG /ENTERPRISE
DIRECTIONS : T /S: 03/15/2010 04:24 PM RDCONTE - --
73 GREGORY ROAD / CAMPBELL TRAINING BLD
TAKE HWY 4215. T/L ON LESLIE CAMPBELL.
T/L ON MAIN STREET. T/R ON BOLTON DRIVE
STORAGE BUILDING WILL BE LOCATED NEXT
TO 193 BOLTON (BESIDE BASEBALL FIELD)
LAND NOTES : LXMN 9/07/06 PARCELS
1106700012 ,110680010501,110670049003,110
6700107, 1106700108 ,1106700113,1106700050
4, 1106700027 ,110670011802,110670011801,1
106700118,1106700098,1106700061 WERE
DELETED AND COMBINED WITH THIS PARCEL
TJONES
STRUCTURE: 000 000 30X30 STORAGE BLDG FOR BASEBALL FIELD
FLOOD ZONE • FLOOD ZONE X
PROPOSED USE STORAGE SEPTIC - EXISTING? • SEWER
PERMIT: CBCO 00 CP BUILDING COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
C151 01 4/16/10 KS C *BLDG FOOTING VRU #: 001910935
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C159 01 4/16/10 KS C *BLDG SLAB INSP VRU #: 001910944
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C151 02 4/19/10 KS C *BLDG FOOTING VRU #: 001912149
4/19/10 AP
C159 02 4/19/10 KS C *BLDG SLAB INSP VRU #: 001912158
4/19/10 _AP
C153 01 4/30/10 / C *BLDG ROUGH IN VRU #: 001918526
G /
PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
E251 01 4/30 /e 0 T C *ELEC ROUGH IN VRU #: 001918535
COMMENTS AND NOTES
PREPARED 5/12/10, 14:17:02 INSPECTION TICKET PAGE 38
F1afnett County INSPECTOR: IVR DATE 5/13/10
ADDRESS . : 193 BOLTON RD SUBDIV:
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073
OWNER . . : CAMPBELL UNIVERSITY PHONE : (910) 893 -4111
PARCEL . . : 11 -0660- - -0191- -02-
APPL NUMBER: 10- 50023976 CP NEW COMMERCIAL BLDG /ENTERPRISE
DIRECTIONS : T /S: 03/15/2010 04:24 PM RDCONTE - --
73 GREGORY ROAD / CAMPBELL TRAINING BLD
TAKE HWY 421S. T/L ON LESLIE CAMPBELL.
T/L ON MAIN STREET. T/R ON BOLTON DRIVE
STORAGE BUILDING WILL BE LOCATED NEXT
TO 193 BOLTON (BESIDE BASEBALL FIELD)
LAND NOTES : LXMN 9/07/06 PARCELS
1106700012 ,110680010501,110670049003,110
6700107, 1106700108 ,1106700113,1106700050
4, 1106700027 ,110670011802,110670011801,1
106700118,1106700098,1106700061 WERE
DELETED AND COMBINED WITH THIS PARCEL
TJONES
STRUCTURE: 000 000 30X30 STORAGE BLDG FOR BASEBALL FIELD
FLOOD ZONE • FLOOD ZONE X
PROPOSED USE • STORAGE SEPTIC - EXISTING • SEWER
PERMIT: CBCO 00 CP BUILDING COPOIERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
C151 01 4/16/10 KS C *BLDG FOOTING VRU #: 001910935
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C159 01 4/16/10 KS C *BLDG SLAB INSP VRU #: 001910944
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM. KSLATTUM
C151 02 4/19/10 KS C *BLDG FOOTING VRU #: 001912149
4/19/10 AP
C159 02 4/19/10 KS C *BLDG SLAB INSP VRU #: 001912158
4/19/10 AP
C153 01 4/30/10 KS C *BLDG ROUGH IN VRU #: 001918526
4/30/10 AP
A814 01 5/13/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001925163
T /S: 05/12/2010 09:40 AM NTART
PERMIT: CPLU 00 CP LAND USE PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
Z820 01 5/13/10 T T� I ® /J PZ *ZONING /FINAL INSPECTION TIME: 17:00 VRU #: 001925171
C. _/4 /A' T /S: 05/12/2010 09:41 AM NTART
COMMENTS AND NOTES
I2 /0.030
NM
_ 13"HDPE Inv In = 19 35
. ,
t ' x'-__„___.„ _�X -X�_ X�__ x_ x 20.0 � �?�� �,
L ` -.offing Cage .► I Proposed
x x x x"x- r • �.r Buildin,
WoM
Vohs --, ,
Box ► N .^ _ � A . A
x x-_._— o • •
-.. Br/co
-- -x x x
_ ' .` / Pump
�_ I
-X_J
Netting
•
Water
Volpe
�� �E Boxes
Brick Wo// with Concrete Cop
•
o ee 4e
Suer smut
•
PREPARED 5/17/10, 15:04:25 INSPECTION TICKET PAGE 2
FZarnett County INSPECTOR: IVR DATE 5/18/10
ADDRESS . : 193 BOLTON RD SUBDIV:
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073
OWNER . . : CAMPBELL UNIVERSITY PHONE : (910) 893 -4111
PARCEL . . : 11 -0660- - -0191- -02-
APPL NUMBER: 10- 50023976 CP NEW COMMERCIAL BLDG /ENTERPRISE
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
E251 01 4/30/10 KS C *ELEC ROUGH IN VRU #: 001918535
4/30/10 AE bond steel to panel
T /S: 04/30/2010 09:40 AM KSLATTUM
E265 01 5/18/)10 C *ELEC FINAL TIME: 17:00 VRU #: 001928225
T /S: 05/17/2010 03:04 PM NTART
COMMENTS AND NOTES
PREPARED 5/17/10, 15:04:25 INSPECTION TICKET PAGE 1
itarnett County INSPECTOR: IVR DATE 5/18/10
a }
ADDRESS . : 193 BOLTON RD SUBDIV:
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639 -2073
OWNER . . : CAMPBELL UNIVERSITY PHONE : (910) 893 -4111
PARCEL . . : 11 -0660- - -0191- -02-
APPL NUMBER: 10- 50023976 CP NEW COMMERCIAL BLDG /ENTERPRISE
DIRECTIONS : T /S: 03/15/2010 04:24 PM RDCONTE - --
73 GREGORY ROAD / CAMPBELL TRAINING BLD
TAKE HWY 421S. T/L ON LESLIE CAMPBELL.
T/L ON MAIN STREET. T/R ON BOLTON DRIVE
STORAGE BUILDING WILL BE LOCATED NEXT
TO 193 BOLTON (BESIDE BASEBALL FIELD)
LAND NOTES : LXMN 9/07/06 PARCELS
1106700012 ,110680010501,110670049003,110
6700107, 1106700108 ,1106700113,1106700050
4, 1106700027 ,110670011802,110670011801,1
106700118,1106700098,1106700061 WERE
DELETED AND COMBINED WITH THIS PARCEL
TJONES
STRUCTURE: 000 000 30X30 STORAGE BLDG FOR BASEBALL FIELD
FLOOD ZONE • FLOOD ZONE X
PROPOSED USE • STORAGE SEPTIC - EXISTING? • SEWER
PERMIT: CBCO 00 CP BUILDING COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
C151 01 4/16/10 KS C *BLDG FOOTING VRU #: 001910935
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C159 01 4/16/10 KS C *BLDG SLAB INSP VRU #: 001910944
4/16/10 DA 1. anchor bolts and hair pins not installed.
2. Wrong size rebar used in mats. Calls for #5's
T /S: 04/16/2010 01:05 PM KSLATTUM
C151 02 4/19/10 KS C *BLDG FOOTING VRU #: 001912149
4/19/10 AP
C159 02 4/19/10 KS C *BLDG SLAB INSP VRU #: 001912158
4/19/10 AP
C153 01 4/30/10 KS C *BLDG ROUGH IN VRU #: 001918526
4/30/10 AP
A814 01 5/13/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001925163
5/13/10 AP T /S: 05/12/2010 09:40 AM NTART
T /S: 05/13/2010 02:11 PM FBURGESS
195 BOLTON RD LILLINGTON, NC 27546
F854 01 5/13/10 MM FM *FINAL INSPECTION TIME: 17:00 VRU #: 001926559
5/13/10 AP T /S: 05/13/2010 02:15 PM NTART
T /S: 05/13/2010 02:15 PM NTART
T /S: 05/13/2010 02:18 PM NTART
C179 01 5/18 10 Tz D C *BLDG FINAL VRU #: 001927664
PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
CONTINUED ONTO NEXT PAGE
r _ rs 3 1 ° 0) ^ ..✓ ,r ^z ®5, 7'16 wy?Fre nF. v.. ',7w-r .w:. .e'.ra ;....
a,
sv
County of Harnett
Building Inspections Department
9 Planning Services
Certificate of Compliance: ✓Occanpanncy: t
Certificate issued pursuant to the requirements of North Carolina General Statute 1 53A-363 and Harnett ;
- County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the
various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following:
Use C1ascation: - V> 2
Permit Numbers
4 Name: •t'nt Building: I u- 0 1 -31 - / G
4
Electrical: ) b • Ste 1-3 9 nl C
a Insulation:
Plumbing:
Mechanical:
t„,
MFG Home:
Date: C� tgo_ Yn Building Official: \. t _ g
Pt ,i v �
`
,/ ,,/ , ,/ i 1 e y