Loading...
INSPECTIONS PREPARED 1/12/10, 14:00:07 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 1/13/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20. PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 TI _ R *BLDG FOOTING / TEMP SVC -POLE VRU #: 001869785 ! U Li/ D -i-C�— COMMENTS AND NOTES V / /y PREPARED 1/15/10, 14:10:36 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 1/19/10 ADDRESS : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/339/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 COMMENTS AND NOTES PREPARED 1/22/10, 13:58:41 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 1/25/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/1 TI R *OPEN FLOOR VRU #: 001875144 1** 2C RP COMMENTS AND NOTES PREPARED 2/15/10, 15:02:36 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/16/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40 3E60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON 5103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS 115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 /16/10 TI FOUR TRADE ROUGH IN VRU #: 001883493 COMMENTS AND NOTES PREPARED 2/17/10, 14:16:57 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/18/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS 115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493 2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON I129 01 2/18/10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543 . (870 Mk RS T /S: 02/17/2010 12:28 PM VBROWN COMMENTS AND NOTES PREPARED 2/19/10, 14:01:46 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 2/22/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS VD ON RIGHT LOT *20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW - WATER SUPPLY UNKNOWN • PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS 115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493 2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON I129 01 2/18/10 • R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543 2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN 1. Any house permitted after 07 -01 -09 shall have R -38 ceiling insulation, unless R -30 can be installed uncompressed OVER THE TOP PLATE. This means it shall extend to the exterior side of the top plate. If that is not fP„ possible, R -38 shall be used. In other cases of R -30, the maximum amount shall not exceed 500 sq ft. See attached. I129 02 /22,210 a n R *INSULATION INSPECTION VRU #: 001885552 'L_- COMMENTS AND NOTES • PREPARED 4/26/10, 14:47:33 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/26/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS 115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493 2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543 2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN 1. Any house permitted after 07 -01 -09 shall have R -38 ceiling insulation, unless R -30 can be installed uncompressed OVER THE TOP PLATE. This means it shall extend to the exterior side of the top plate. If that is not possible, R -38 shall be used. In other cases of R -30, the maximum amount shall not exceed 500 sq ft. See attached. I129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552 2/22/10 DP R38 C shall be used in ceiling. see previous violation. Remove sheetrock on ceiling infront bedrooms $50.00 re- inspection fee T /S: 02/22/2010 11:41 AM KSLATTUM T /S: 02/22/2010 11:46 AM KSLATTUM T /S: 04/26/2010 02:25 PM NTART T /S: 04/26/2010 02:26 PM NTART T /S: 04/26/2010 02:38 PM NTART I129 03 2/26/10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001916600 2r2.`1 /Qr T /S: 04/26/2010 02:47 PM NTART S COMMENTS AND NOTES PREPARED 4/26/10, 14:48:51 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/27/10 ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 B5 R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FE ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS 115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493 2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543 2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN 1. Any house permitted after 07 -01 -09 shall have R -38 ceiling insulation, unless R -30 can be installed uncompressed OVER THE TOP PLATE. This means it shall extend to the exterior side of the top plate. If that is not possible, R -38 shall be used. In other cases of R -30, the maximum amount shall not exceed 500 sq ft. See attached. I129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552 2/22/10 DP R38 C shall be used in ceiling. see previous violation. Remove sheetrock on ceiling infront bedrooms $50.00 re- inspection fee T /S: 02/22/2010 11:41 AM KSLATTUM T /S: 02/22/2010 11:46 AM KSLATTUM T /S: 04/26/2010 02:25 PM NTART T /S: 04/26/2010 02:26 PM NTART T /S: 04/26/2010 02:38 PM NTART I129 03 2/26/10 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001916600 2/26/10 AP T /S: 04/26/2010 02:47 PM NTART T /S: 04/26/2010 02:48 PM NTART R429 01 4/27/10 TI FOUR TRADE FINAL VRU #: 001916188 4/26/10 CA T /S: 04/26/2010 02:19 PM NTART R429 02 4/27/10 T FOUR TRADE FINAL TIME: 17:00 VRU #: 001916618 111%O 4 j t T /S: 04/26/2010 02:48 PM NTART COMMENTS AND NOTES PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 3 Harnett - Count^; „- - INSPECTOR: IVR DATE 5/14/10 ADDRESS : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSP 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13 /10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON 8105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FE ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS N/115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493 2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543 2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN 1. Any house permitted after 07 -01 -09 shall have R -38 ceiling insulation, unless R -30 can be installed uncompressed OVER THE TOP PLATE. This means it shall extend to the exterior side of the top plate. If that is not possible, R -38 shall be used. In other cases of R -30, the maximum amount shall not exceed 500 sq ft. See attached. I129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552 2/22/10 DP R38 C shall be used in ceiling. see previous violation. Remove sheetrock on ceiling infront bedrooms $50.00 re- inspection fee T /S: 02/22/2010 11:41 AM KSLATTUM T /S: 02/22/2010 11:46 AM KSLATTUM T /S: 04/26/2010 02:25 PM NTART T /S: 04/26/2010 02:26 PM NTART T /S: 04/26/2010 02 :38 PM NTART 1129 03 2/26/10 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001916600 2/26/10 AP T /S: 04/26/2010 02:47 PM NTART T /S: 04/26/2010 02:48 PM NTART R429 01 4/27/10 TI FOUR TRADE FINAL VRU #: 001916188 4/26/10 CA T /S: 04/26/2010 02:19 PM NTART R429 02 4/27/10 FOUR TRADE FINAL TIME: 17:00 VRU #: 001916618 4/27/10 DP T /S: 04/26/2010 02:48 PM NTART 1. No vents in foundation under porches. 2. No access door in garage ceiling. 3. Cap future drain in attic. 4. Insulate around attic door.5. No bonding point at service • ground. 6. Water heater cannot be more than 20 feet from CONTINUED ONTO NEXT PAGE PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 4 Harnett County J 31 . q INSPECTOR: IVR DATE 5/14/10 ' ADDRESS : 115 .NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . . : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- - APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS access door. 7. Water heater not wired. $50 re fee R429-03 5/14/10 T FOUR TRADE FINAL VRU #: 001925726 COMMENTS AND NOTES HTE# n-; -5 - ir .S t- Harnett County Department of Public Health 21 0 2 6 .. • • HPERMIT # Z3 fl / Operation Pe sit New Installation 01 Septic Tank ❑ Repair IJ Nitrification Line ❑ Expansion • PROPERTY LO(ATION:4c /IMO Cij+ -a„ .„) Name: (owner) ZOM beij j Y SUBDIVISION AAA— Par- LOT # _ System Installer: F'esi(,Qa 3cc1 Registration # Basement with plumbing: ❑ Garage l ' Number of Bedrooms Type of .Water Supply: ❑ Community 124ublic ❑ Well Distance from well feet System Type: - 7.5`o' R.bMncfLti.—.. *2%j%4.&. Types V and VI Systems expire in 5 years. (In accordance with Table V. a) // Owner must contact Health Department 6 months prior to expiration for permit renewal. This system has been installed in compliance with applicable North Carolina General Statutes, Ruks for Sewage Treatment and Disposal, and all conditions of the Improvement Permit and Construction Authorinrion. t Foil r SrAtif 6' flJ e)/t/QTr+.! Gr.-4J a-, ae W/ L t ?fi T�s1,3C 44lewS LIP crti4 sp A0 .3 e•t( E (? Ns 6, 9� 0 5P ..... is' vA .111‘p SV PERMIT CONDITIONS: • 1 Performance: System shall perform in accordance with Rule .1961. 11. Monitoring. As required by Rule .1961. 111. Maintenance: As required by Rule .1961. Other. Subsurface system operator required? Yes ❑ No ❑ II yes, see attached sheet for additional operation conditions, maintenance and reporting. IY. Operation: V. Other. Following are the specifications for the sewap - disposal system on the above captioned property. Type of system: ❑ Conventional 1 Other 79:70 Env( no- S Septic Tank: / gallons Pump Tank: gallons Subsurface • No. of exact length width of depth of Drainage Field ditches 3 of each ditch So feet ditches 3 feet ditches Z inches French Drain Required: Linear feet Authorized State 7 /7 Date 4- 1t to PREPARED 5/17/10, 14:34:39 INSPECTION TICKET PAGE 1 Harnett. Count y. INSPECTOR: IVR DATE 5/18/10 ADDRESS : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER . : IOM LAND COMPANY LLC #20 PHONE : PARCEL : 04 -0673- -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT LOT #20 JB STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW WATER SUPPLY • UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785 1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON 8103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076 1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144 1/25/10 AP A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722 1/28/10 AP R' /S: 01/28/2010 01:39 PM FBURGESS 115 NEW RIVER CT ANGIER, NC 27501 LOT 20 R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493 2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543 2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN 1. Any house permitted after 07 -01 -09 shall have R -38 ceiling insulation, unless R -30 can be installed uncompressed OVER THE TOP PLATE. This means it shall extend to the exterior side of the top plate. If that is not possible, R -38 shall be used. In other cases of R -30, the maximum amount shall not exceed 500 sq ft. See attached. 1129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552 2/22/10 DP R38 C shall be used in ceiling. see previous violation. Remove sheetrock on ceiling infront bedrooms $50.00 re- inspection fee T /S: 02/22/2010 11:41 AM KSLATTUM T /S: 02/22/2010 11:46 AM KSLATTUM T /S: 04/26/2010 02:25 PM NTART T /S: 04/26/2010 02:26 PM NTART T /S: 04/26/2010 02:38 PM NTART I129 03 2/26/10 KS R *INSULATION INSPECTION - TIME: 17:00 VRU #: 001916600 2/26/10 AP T /S: 04/26/2010 02:47 PM NTART /S: 04/26/2010 02:48 PM NTART H824 01 4/19/10 JM JENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001926609 4/19/10 AP T /S: 05/13/2010 02:26 PM SSTEWART T /S: 05/13/2010 02:26 PM SSTEWART R429 01 4/27/10 TI FOUR TRADE FINAL VRU #: 001916188 4/26/10 CA T /S: 04/26/2010 02:19 PM NTART R429 02 4/27/10 BS FOUR TRADE FINAL TIME: 17:00 VRU #: 001916618 4/27/10 DP T /S: 04/26/2010 02:48 PM NTART CONTINUED ONTO NEXT PAGE PRE$ARED . 5/17/10, 14:34:39 INSPECTION TICKET PAGE 2 Harnett County, INSPECTOR: IVR DATE 5/18/10 rr ADDRESS' . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS CONTRACTOR STANCIL BUILDERS INC. PHONE : (919) 639 -2073 OWNER:.. : IOM LAND COMPANY LLC #20 PHONE : PARCEL . . : 04 -0673- - -0134- -23- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 1. No vents in foundation under porches. 2. No access door in garage ceiling. 3. Cap future drain in attic. 4. Insulate around attic door.5. No bonding point at service ground. 6. Water heater cannot be more than 20 feet from access door. 7. Water heater not wired. $50 re fee R429 03 5/14/10 B5 FOUR TRADE FINAL VRU #: 001925726 5/14/10 DP 1. Previous violation (cap off upstairs future drain) not corrected. this drain is tied into the existing waste system. 2. Wiring under floor at front right corner of house not stapled. Range wire is looped and hanging under house. Insulation has been pushed out of floor system where wiring was done after floor was insulated T /S: 05/17/2010 09:54 AM NTART T /S: 05/17/2010 09:58 AM NTART R429 04 5/18/10 As FOUR TRADE FINAL VRU #: 001927748 SW/0 COMMENTS AND NOTES County of Harnett Building Inspections Department Planning Services [�� 1 0 Certificate of Compliance: Occupancy: x /� Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett ' 4 County Zoning Ordinances: This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: SFD Permit Numbers V "' 1 A Name: Stancil. Builders Building: 07 50016656 JJJ Electrical: 07- 50016656 �- Address: 115 New River Ct Insulation: 07- 50016656 � ' '0` Angler NC Plumbing: 07- 50016656 f "/�� Mechanical: 07-50016656 MFG Home: Nix Date: 05 -18 -2010 BuildingOfficial:Br Sutt it f