INSPECTIONS PREPARED 1/12/10, 14:00:07 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 1/13/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20. PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 TI _ R *BLDG FOOTING / TEMP SVC -POLE VRU #: 001869785
! U
Li/ D -i-C�—
COMMENTS AND NOTES
V / /y
PREPARED 1/15/10, 14:10:36 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 1/19/10
ADDRESS : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/339/10 TI R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
COMMENTS AND NOTES
PREPARED 1/22/10, 13:58:41 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 1/25/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
8101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/1 TI R *OPEN FLOOR VRU #: 001875144
1** 2C RP
COMMENTS AND NOTES
PREPARED 2/15/10, 15:02:36 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 2/16/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40 3E60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
5103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS
115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 /16/10 TI FOUR TRADE ROUGH IN VRU #: 001883493
COMMENTS AND NOTES
PREPARED 2/17/10, 14:16:57 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 2/18/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS
115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493
2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON
I129 01 2/18/10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543
. (870 Mk RS T /S: 02/17/2010 12:28 PM VBROWN
COMMENTS AND NOTES
PREPARED 2/19/10, 14:01:46 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 2/22/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS VD ON RIGHT
LOT *20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - NEW - WATER SUPPLY UNKNOWN •
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS
115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493
2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON
I129 01 2/18/10 • R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543
2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN
1. Any house permitted after 07 -01 -09 shall have R -38
ceiling insulation, unless R -30 can be installed
uncompressed OVER THE TOP PLATE. This means it shall extend
to the exterior side of the top plate. If that is not fP„
possible, R -38 shall be used. In other cases of R -30, the
maximum amount shall not exceed 500 sq ft. See attached.
I129 02 /22,210 a n R *INSULATION INSPECTION VRU #: 001885552
'L_-
COMMENTS AND NOTES
•
PREPARED 4/26/10, 14:47:33 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 2/26/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING? • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS
115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493
2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON
I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543
2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN
1. Any house permitted after 07 -01 -09 shall have R -38
ceiling insulation, unless R -30 can be installed
uncompressed OVER THE TOP PLATE. This means it shall extend
to the exterior side of the top plate. If that is not
possible, R -38 shall be used. In other cases of R -30, the
maximum amount shall not exceed 500 sq ft. See attached.
I129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552
2/22/10 DP R38 C shall be used in ceiling. see previous violation.
Remove sheetrock on ceiling infront bedrooms
$50.00 re- inspection fee
T /S: 02/22/2010 11:41 AM KSLATTUM
T /S: 02/22/2010 11:46 AM KSLATTUM
T /S: 04/26/2010 02:25 PM NTART
T /S: 04/26/2010 02:26 PM NTART
T /S: 04/26/2010 02:38 PM NTART
I129 03 2/26/10 TI R *INSULATION INSPECTION TIME: 17:00 VRU #: 001916600
2r2.`1 /Qr T /S: 04/26/2010 02:47 PM NTART
S
COMMENTS AND NOTES
PREPARED 4/26/10, 14:48:51 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 4/27/10
ADDRESS . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 B5 R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FE ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS
115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493
2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON
I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543
2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN
1. Any house permitted after 07 -01 -09 shall have R -38
ceiling insulation, unless R -30 can be installed
uncompressed OVER THE TOP PLATE. This means it shall extend
to the exterior side of the top plate. If that is not
possible, R -38 shall be used. In other cases of R -30, the
maximum amount shall not exceed 500 sq ft. See attached.
I129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552
2/22/10 DP R38 C shall be used in ceiling. see previous violation.
Remove sheetrock on ceiling infront bedrooms
$50.00 re- inspection fee
T /S: 02/22/2010 11:41 AM KSLATTUM
T /S: 02/22/2010 11:46 AM KSLATTUM
T /S: 04/26/2010 02:25 PM NTART
T /S: 04/26/2010 02:26 PM NTART
T /S: 04/26/2010 02:38 PM NTART
I129 03 2/26/10 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001916600
2/26/10 AP T /S: 04/26/2010 02:47 PM NTART
T /S: 04/26/2010 02:48 PM NTART
R429 01 4/27/10 TI FOUR TRADE FINAL VRU #: 001916188
4/26/10 CA T /S: 04/26/2010 02:19 PM NTART
R429 02 4/27/10 T FOUR TRADE FINAL TIME: 17:00 VRU #: 001916618
111%O 4 j t T /S: 04/26/2010 02:48 PM NTART
COMMENTS AND NOTES
PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 3
Harnett - Count^; „- - INSPECTOR: IVR DATE 5/14/10
ADDRESS : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSP 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13 /10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
B103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
8105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FE ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP T /S: 01/28/2010 01:39 PM FBURGESS
N/115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493
2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON
I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543
2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN
1. Any house permitted after 07 -01 -09 shall have R -38
ceiling insulation, unless R -30 can be installed
uncompressed OVER THE TOP PLATE. This means it shall extend
to the exterior side of the top plate. If that is not
possible, R -38 shall be used. In other cases of R -30, the
maximum amount shall not exceed 500 sq ft. See attached.
I129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552
2/22/10 DP R38 C shall be used in ceiling. see previous violation.
Remove sheetrock on ceiling infront bedrooms
$50.00 re- inspection fee
T /S: 02/22/2010 11:41 AM KSLATTUM
T /S: 02/22/2010 11:46 AM KSLATTUM
T /S: 04/26/2010 02:25 PM NTART
T /S: 04/26/2010 02:26 PM NTART
T /S: 04/26/2010 02 :38 PM NTART
1129 03 2/26/10 KS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001916600
2/26/10 AP T /S: 04/26/2010 02:47 PM NTART
T /S: 04/26/2010 02:48 PM NTART
R429 01 4/27/10 TI FOUR TRADE FINAL VRU #: 001916188
4/26/10 CA T /S: 04/26/2010 02:19 PM NTART
R429 02 4/27/10 FOUR TRADE FINAL TIME: 17:00 VRU #: 001916618
4/27/10 DP T /S: 04/26/2010 02:48 PM NTART
1. No vents in foundation under porches. 2. No access door
in garage ceiling. 3. Cap future drain in attic. 4.
Insulate around attic door.5. No bonding point at service
•
ground. 6. Water heater cannot be more than 20 feet from
CONTINUED ONTO NEXT PAGE
PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 4
Harnett County J 31 . q INSPECTOR: IVR DATE 5/14/10
' ADDRESS : 115 .NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
- APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
access door. 7. Water heater not wired. $50 re fee
R429-03 5/14/10 T FOUR TRADE FINAL VRU #: 001925726
COMMENTS AND NOTES
HTE# n-; -5 - ir .S t- Harnett County Department of Public Health 21 0 2 6
.. • • HPERMIT # Z3 fl / Operation Pe sit
New Installation 01 Septic Tank ❑ Repair IJ Nitrification Line ❑ Expansion
• PROPERTY LO(ATION:4c /IMO Cij+ -a„ .„)
Name: (owner) ZOM beij j Y SUBDIVISION AAA— Par- LOT # _
System Installer: F'esi(,Qa 3cc1 Registration #
Basement with plumbing: ❑ Garage l ' Number of Bedrooms
Type of .Water Supply: ❑ Community 124ublic ❑ Well Distance from well feet
System Type: - 7.5`o' R.bMncfLti.—.. *2%j%4.&. Types V and VI Systems expire in 5 years.
(In accordance with Table V. a) // Owner must contact Health Department 6 months prior to expiration for permit renewal.
This system has been installed in compliance with applicable North Carolina General Statutes, Ruks for Sewage Treatment and Disposal, and all conditions of the Improvement Permit and Construction Authorinrion.
t Foil r SrAtif 6' flJ
e)/t/QTr+.! Gr.-4J a-,
ae W/ L t ?fi T�s1,3C 44lewS
LIP crti4 sp A0 .3
e•t( E (?
Ns 6,
9�
0 5P .....
is'
vA .111‘p SV
PERMIT CONDITIONS: •
1 Performance: System shall perform in accordance with Rule .1961.
11. Monitoring. As required by Rule .1961.
111. Maintenance: As required by Rule .1961. Other.
Subsurface system operator required? Yes ❑ No ❑
II yes, see attached sheet for additional operation conditions, maintenance and reporting.
IY. Operation:
V. Other.
Following are the specifications for the sewap - disposal system on the above captioned property.
Type of system: ❑ Conventional 1 Other 79:70 Env( no- S Septic Tank: / gallons Pump Tank: gallons
Subsurface • No. of exact length width of depth of
Drainage Field ditches 3 of each ditch So feet ditches 3 feet ditches Z inches
French Drain Required: Linear feet
Authorized State 7 /7 Date 4- 1t to
PREPARED 5/17/10, 14:34:39 INSPECTION TICKET PAGE 1
Harnett. Count y. INSPECTOR: IVR DATE 5/18/10
ADDRESS : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR : STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER . : IOM LAND COMPANY LLC #20 PHONE :
PARCEL : 04 -0673- -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 210 E LEFT ON JAME NORRIS S/D ON RIGHT
LOT #20 JB
STRUCTURE: 000 000 40X60 CRAWL 3BD /2.5BA W /GAR & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING? • NEW WATER SUPPLY • UNKNOWN
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 1/13/10 BS R *BLDG FOOTING / TEMP SVC POLE VRU #: 001869785
1/13/10 AP T /S: January 13, 2010 12:00 PM BSUTTON
8103 01 1/19/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001872076
1/20/10 AP T /S: January 20, 2010 07:39 AM BSUTTON
B105 01 1/25/10 KS R *OPEN FLOOR VRU #: 001875144
1/25/10 AP
A814 01 2/02/10 FB ADDRESS CONFIRMATION VRU #: 001876722
1/28/10 AP R' /S: 01/28/2010 01:39 PM FBURGESS
115 NEW RIVER CT ANGIER, NC 27501 LOT 20
R425 01 2/16/10 BS FOUR TRADE ROUGH IN VRU #: 001883493
2/16/10 AP T /S: February 16, 2010 02:17 PM BSUTTON
I129 01 2/18/10 BS R *INSULATION INSPECTION TIME: 17:00 VRU #: 001884543
2/18/10 DA T /S: 02/17/2010 12:28 PM VBROWN
1. Any house permitted after 07 -01 -09 shall have R -38
ceiling insulation, unless R -30 can be installed
uncompressed OVER THE TOP PLATE. This means it shall extend
to the exterior side of the top plate. If that is not
possible, R -38 shall be used. In other cases of R -30, the
maximum amount shall not exceed 500 sq ft. See attached.
1129 02 2/22/10 KS R *INSULATION INSPECTION VRU #: 001885552
2/22/10 DP R38 C shall be used in ceiling. see previous violation.
Remove sheetrock on ceiling infront bedrooms
$50.00 re- inspection fee
T /S: 02/22/2010 11:41 AM KSLATTUM
T /S: 02/22/2010 11:46 AM KSLATTUM
T /S: 04/26/2010 02:25 PM NTART
T /S: 04/26/2010 02:26 PM NTART
T /S: 04/26/2010 02:38 PM NTART
I129 03 2/26/10 KS R *INSULATION INSPECTION - TIME: 17:00 VRU #: 001916600
2/26/10 AP T /S: 04/26/2010 02:47 PM NTART
/S: 04/26/2010 02:48 PM NTART
H824 01 4/19/10 JM JENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001926609
4/19/10 AP T /S: 05/13/2010 02:26 PM SSTEWART
T /S: 05/13/2010 02:26 PM SSTEWART
R429 01 4/27/10 TI FOUR TRADE FINAL VRU #: 001916188
4/26/10 CA T /S: 04/26/2010 02:19 PM NTART
R429 02 4/27/10 BS FOUR TRADE FINAL TIME: 17:00 VRU #: 001916618
4/27/10 DP T /S: 04/26/2010 02:48 PM NTART
CONTINUED ONTO NEXT PAGE
PRE$ARED . 5/17/10, 14:34:39 INSPECTION TICKET PAGE 2
Harnett County, INSPECTOR: IVR DATE 5/18/10
rr
ADDRESS' . : 115 NEW RIVER CT SUBDIV: AUTUMN POINTE 29 LOTS
CONTRACTOR STANCIL BUILDERS INC. PHONE : (919) 639 -2073
OWNER:.. : IOM LAND COMPANY LLC #20 PHONE :
PARCEL . . : 04 -0673- - -0134- -23-
APPL NUMBER: 07- 50016656 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
1. No vents in foundation under porches. 2. No access door
in garage ceiling. 3. Cap future drain in attic. 4.
Insulate around attic door.5. No bonding point at service
ground. 6. Water heater cannot be more than 20 feet from
access door. 7. Water heater not wired. $50 re fee
R429 03 5/14/10 B5 FOUR TRADE FINAL VRU #: 001925726
5/14/10 DP 1. Previous violation (cap off upstairs future drain) not
corrected. this drain is tied into the existing waste
system. 2. Wiring under floor at front right corner of
house not stapled. Range wire is looped and hanging under
house. Insulation has been pushed out of floor system where
wiring was done after floor was insulated
T /S: 05/17/2010 09:54 AM NTART
T /S: 05/17/2010 09:58 AM NTART
R429 04 5/18/10 As FOUR TRADE FINAL VRU #: 001927748
SW/0
COMMENTS AND NOTES
County of Harnett
Building Inspections Department
Planning Services [��
1
0 Certificate of Compliance: Occupancy: x
/� Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett '
4 County Zoning Ordinances: This certifies at the time of issuance, this structure was in compliance with the
various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following:
Use Classification: SFD Permit Numbers V "'
1 A Name: Stancil. Builders Building: 07 50016656
JJJ Electrical: 07- 50016656
�- Address: 115 New River Ct Insulation: 07- 50016656 � '
'0` Angler NC Plumbing: 07- 50016656 f
"/�� Mechanical: 07-50016656
MFG Home: Nix
Date: 05 -18 -2010 BuildingOfficial:Br Sutt
it f