Loading...
IPACHTE# I - -3 Harnett County Department of Public Health Improvement Permit 27583 A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION ISSUED TO: SUBDIVISION v LH # /O NEW EPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: Proposed Wastewater System Type: P '}'-) Projected Daily Flow: D Number of bedrooms: — Number of Occupants: 6 _max Basement ❑Yes , L�'N0 Pump Required: [ es ❑ No ❑ May be required based on final location and elevations of facilities Type of Water Supply: ❑ Community Public ❑ Well Distance from well feet Permit valid for. ve years Permit conditions: El No expiration t,�n5s �I Authorized State A � /D —/—/3 SEE ATTACHED SITE SKETCH The issuance of this permit by a Ith Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if t e site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorizatio Required for Building Permit The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: L04Z Ap� . -r4ue� PROPERTY LOCATION: SUBDIVISION i LOT # _ Facility Type: 12 New ❑ Expansion ❑ Repair Basement? ❑ Yes No Basement Fixtures? ❑ Yes 21 o Type of Wastewater System ** ?--T9 4t 433 (Initial) Wastewater Flow: 369 GPD (See note below, if applicable 0)1 p ZS--% pair) Installation Requirements /Conditions Number of trenches y, Septic Tank Size 01> gallons Exact length of each trench -757 feet Trench Spacing: _ Feet on Center Pump Tank Size 'rte gallons Trenches shall be installed on contour at a Soil Cover:_ inches Maximum Trench Depth of: ZZ >t $ inches (Maximum Boll cover shall not exceed (Trench bottoms shall be level to +/ -1/4" 36" above the trench bottom) in all directions) f Pump Requirements: ft. TDH vs. GPM 'f inches below pipe Aggregate Depth: inches above pipe Conditions: 6"- v=z_. )4-b ,'mot et° r' 623 sir ie/tinnv -ko inches total WATER LINES (INCLUDING IRRIGATION) MUST BE 10FT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. * *If applicable: / understand the system type specified is di /ferent from the type speciped on the application. /accept the specipcations of this permit. Owner /Legal Representative Signature: Date: This Construction Authorization is subiect to revocation if the site clan, slat. or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownership of the site. This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State nt: Date: J'Y' — / Construction Authorization Expiration Date: /-v — HTE# Permit # 275-8-5 Harnett County Department of "liblic Health Site Sketch PROPERTY LOCATC ISSUED TO: 1�6r�7'O.i�` ��Z' —� TIC— SUBDIVISION Authorized State J, Date: J� `J �— ► 3 7 zZ,12 LOT # /0 Department of Environment, Health and Natural Resources Division of Environmental Health On -Site Wastewater Section SOIL /SITE EVALUATION for ON -SITE WASTEWATER SYSTEM Owner: Applicant: C-6 Address: CenvF luated: Proposed Facility: ow (.194 9): Location of Site: Property Recorded: Water Supply: ublic❑ Individual ❑ Well Evaluation Method:[] ger Boring ❑ Pit ❑ Cut Type of Wastewater: Q- S'e'wage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: ❑ Spring ❑ Other ❑ Mixed P R O F I L E # .1940 Landscape Position/ Slope % Horizon Depth (In.) SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS Profile Class & LTAR .1941 Structure/ Texture .1941 Consistence Mineralogy .1942 Soil Wetness/ Color .1943 Soil Depth (IN.) .1956 Sapro Class .1944 Restr Horiz 3 L ` - c 5c, 1S'I rr -1% SL Description Initial system Repair System Other Factors ( 1946): Site Classification (.1948): j Evaluated By: Others Present: Available Space (.1945) System Type(s) Site LTAR