INSPECTIONS PREPARED 11/05/09, 13:58:55 INSPECTION TICKET PAGE 44
Harnett County INSPECTOR: IVR DATE 11/06/09
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
U 6 •9
COMMENTS AND NOTES
1
i
PREPARED 11/17/09, 13:59:53 INSPECTION TICKET PAGE 25
Harnett County INSPECTOR: IVR DATE 11/18/09
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
B103 01 11/18/09 TZ R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
I I - 1g - of
A814 01 11/18/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
T /S: 11/17/2009 01:28 PM DJOHNSON
T /S: 11/17/2009 01:29 PM DJOHNSON
COMMENTS AND NOTES
PREPARED 11/24/09, 14:00:31 INSPECTION TICKET PAGE 33
Harnett County INSPECTOR: IVR DATE 11/25/09
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP 24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
3105 01 1 I/ZS,n ` R *OPEN FLOOR VRU #: 001854835
COMMENTS AND NOTES
PREPARED 1/08/10, 13:58:37 INSPECTION TICKET PAGE 9
Harnett County INSPECTOR: IVR DATE 1 /11 /10
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39%34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP 24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
8105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835
11/25/09 AP
R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928
1/06/10 CA
R425 02 1 /08 /10 JH FOUR TRADE ROUGH IN VRU #: 001868512
1/08/10 CA T /S: 01/08/2010 10:54 AM JBROCK
R425 03 1/11/10 TI FOUR TRADE ROUGH IN VRU #: 001869023
�H n )
COMMENTS AND NOTES
PREPARED 1/14/10, 13:58:51 INSPECTION TICKET PAGE 19
Harnett County INSPECTOR: IVR DATE 1/15/10
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP 24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
B105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835
11/25/09 AP
R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928
1/06/10 CA
R425 02 1 /08 /10 JH FOUR TRADE ROUGH IN VRU #: 001868512
1 /08 /10 CA T /S: 01/08/2010 10:54 AM JBROCK
R425 03 1/11/10 DT FOUR TRADE ROUGH IN VRU #: 001869023
1/11/10 DA 1. No test on pex.
2. B1 trusses not strapped at joint 9
3. Branch drain must extend beyond foundation wall
4. Ladder frame gables.
T /S: 01/11/2010 02:11 PM DETAYLOR
I129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668
1/13/10 DA Rough in not approved.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 04 1/13/10 + FOUR TRADE ROUGH IN VRU #: 001869643
1/13/10 1. Still do not have 100 psi on water lines.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 05 1/15/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971
/../c/0 , f T /S: 01/14/2010 09:34 AM DJOHNSON
COMMENTS AND NOTES
P REPARED 1/12/10, 14:00:07 INSPECTION TICKET PAGE 17
Harnett County INSPECTOR: IVR DATE 1/13/10
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
.# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
8101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM, MREARIC
8103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP 24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
B105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835
11/25/09 AP
R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928
1/06/10 CA
R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512
1/08/10 CA T /S: 01/08/2010 10:54 AN JBROCK
R425 03 1/11/10 FOUR TRADE ROUGH IN VRU #: 001869023
1/11/10 DA 1. No test on pex.
2. B1 trusses not strapped at joint 9
3. Branch drain must extend beyond foundation wall
4. Ladder frame gables.
T /S: 01/11/2010 02:11 PM DETAYLOR
I129 01 (/13 /13/10 TI R *INSULATION INSPECTION VRU #: 001869668
7 i7
R425 04 1/11/10 TI FOUR TRADE ROUGH IN VRU #: 001869643
(/ 11_ •
COMMENTS AND NOTES
PREPARED 4/05/10, 10:20:33 INSPECTION TICKET PAGE 2
Hai?'ett County INSPECTOR: IVR DATE 4/05/10
ADDRESS : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
T /S: 01/22/2010 11:28 AM SSTEWART
R429 01 4/01/10 JH FOUR TRADE FINAL VRU #: 001902998
4/01/10 DP 1)Need receptacle on front of house accessible from grade.
2)Need 2oamp receptacle for microwave.
3)Cleanout to grade & cover with at least 3" of dirt.
4)Label AHU in attic & crawl space.
5)Sleeve refrigerant lines in foundation wall.
6)Breaker for condesing units to big & they are not wired.
I129 02 4/05/10 TI INSULATION INSPECTION TIME: 17:00 VRU #: 001904952
/ ') - A5: 04/05/2010 10:20 AM DJOHNSON
COMMENTS AND NOTES
PREPARED 4/05/10, 16:31:31 INSPECTION TICKET PAGE 1
Harnett Eounty INSPECTOR: IVR DATE 4/06/10
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39 7E34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
8103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP 24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
8105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835
11/25/09 AP
R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928
1/06/10 CA
R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512
1/08/10 CA T /S: 01/08/2010 10:54 AM JBROCK
R425 03 1 /11 /10 DT FOUR TRADE ROUGH IN VRU #: 001869023
1 /11 /10 DA 1. No test on pex.
2. B1 trusses not strapped at joint 9
3. Branch drain must extend beyond foundation wall
4. Ladder frame gables.
T /S: 01/11/2010 02:11 PM DETAYLOR
1129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668
1/13/10 DA Rough in not approved.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 04 1/13/10 DT FOUR TRADE ROUGH IN VRU #: 001869643
1/13/10 DP 1. Still do not have 100 psi on water lines.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 05 1/15/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971
1/15/10 AP T /S: 01/14/2010 09:34 AM DJOHNSON
T /S: January 15, 2010 11:47 AM BSUTTON
H824 01 1/21/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001875210
1/21/10 AP T /S: 01/22/2010 11:27 AM SSTEWART
CONTINUED ONTO NEXT PAGE
PREPARED 4/05/10, 16:31:31 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 4/06/10
ADD1ESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
T /S: 01/22/2010 11:28 AM SSTEWART
R429 01 4/01/10 JH FOUR TRADE FINAL VRU #: 001902998
4/01/10 DP ITNeed receptacle on front of house accessible from grade.
2)Need 20amp receptacle for microwave.
3)Cleanout to grade & cover with at least 3" of dirt.
*Label AHU in attic & crawl space.
Sleeve refrigerant lines in foundation wall.
6)Breaker for condesing units to big & they are not wired.
I129 02 4/05/10 DT R +INSULATION INSPECTION TIME: 17:00 VRU #: 001904952
4/05/10 AP T /S: 04/05/2010 10:20 AM DJOHNSON
R429 02 4/06/10 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 001905397
(j- y • i p
400 T /S: 04/05/2010 04:31 PM DJOHNSON
COMMENTS AND NOTES
PREPARED 3/31/10, 13:58:33 INSPECTION TICKET PAGE 18
Harnett County INSPECTOR: IVR DATE 4/01/10
ADDRESS . : 24; EMMA SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP \/24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
B105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835
11/25/09 AP
R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928
1/06/10 CA
R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512
1/08/10 CA T /S: 01/08/2010 10:54 AM JEROCK
R425 03 1 /11 /10 DT FOUR TRADE ROUGH IN VRU #: 001869023
1 /11 /10 DA 1. No test on pex.
2. B1 trusses not strapped at joint 9
3. Branch drain must extend beyond foundation wall
4. Ladder frame gables.
T /S: 01/11/2010 02:11 PM DETAYLOR
I129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668
1/13/10 DA Rough in not approved.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 04 1/13/10 DT FOUR TRADE ROUGH IN VRU #: 001869643
1/13/10 DP 1. Still do not have 100 psi on water lines.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 05 1/15/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971
1/15/10 AP T /S: 01/14/2010 09:34 AM DJOHNSON
T /S: January 15, 2010 11:47 AM BSUTTON
H824 01 1/21/10 OT fENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001875210
1/21/10 AP T /S: 01/22/2010 11:27 AM SSTEWART
T /S: 01/22/2010 11:28 AM SSTEWART
CONTINUED ONTO NEXT PAGE
PREPARED 3/31/10, 13:58:33 INSPECTION TICKET PAGE 19
Harnett County INSPECTOR: IVR DATE 4/01/10
ADDRESS . : 24EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMNS INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12- 0555 - - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
R429 01 4/01/10 TI �, FOUR TRADE FINAL VRU #: 001902998
j<
COMMENTS AND NOTES
jPREPJIRED 4/07/10, 13:59:47 INSPECTION TICKET PAGE 17
Harnett=County INSPECTOR: IVR DATE 4/08/10
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : ABC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - --
KENLAN FARMS #37
US HWY 401 S TO RIGHT ON MCNEILL HOBBS
RD TO LEFT ON WIRE RD PASS JOSEY
WILLIAMS ON THE LEFT AND TURN RIGHT ON
KENLAN RD
T /S: 11/17/2009 01:32 PM DJOHNSON --
* * * * * ** *PREMISE # 55390924 * * * * * **
STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210
11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC
B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856
11/18/09 AP
A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914
11/18/09 AP 24 EMMA CT
LINDEN 28356
T /S: 11/18/2009 02:05 PM TWARD
8105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835
11/25/09 AP
R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928
1/06/10 CA
R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512
1 /08 /10 CA T /S: 01/08/2010 10:54 AM JBROCK
R425 03 1/11/10 DT FOUR TRADE ROUGH IN VRU #: 001869023
1 /11 /10 DA 1. No test on pex.
2. B1 trusses not strapped at joint 9
3. Branch drain must extend beyond foundation wall
4. Ladder frame gables.
T /S: 01/11/2010 02:11 PM DETAYLOR
I129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668
1/13/10 DA Rough in not approved.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 04 1/13/10 DT FOUR TRADE ROUGH IN VRU #: 001869643
1/13/10 DP 1. Still do not have 100 psi on water lines.
T /S: 01/13/2010 11:40 AM DETAYLOR
R425 05 1/15/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971
1/15/10 AP T /S: 01/14/2010 09:34 AM DJOHNSON
T /S: January 15, 2010 11:47 AM BSUTTON
H824 01 1/21/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001875210
1/21/10 AP T /S: 01/22/2010 11:27 AM SSTEWART
T /S: 01/22/2010 11:28 AM SSTEWART
CONTINUED ONTO NEXT PAGE
/PREPARED 4/07/10, 13:59:47 INSPECTION TICKET PAGE 18
Harnett•County INSPECTOR: IVR DATE 4/08/10
ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS
CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555
OWNER . . : ABJ INVESTMENTS LLC PHONE :
PARCEL . . : 12 -0555- - -0216- -37-
APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
R429 01 4/01/10 JH FOUR TRADE FINAL VRU #: 001902998
4/01/10 DP 1)Need receptacle on front of house accessible from grade.
2)Need 20amp receptacle for microwave.
3)Cleanout to grade & cover with at least 3" of dirt.
4)Label AHU in attic & crawl space.
5)Sleeve refrigerant lines in foundation wall.
6)Breaker for condesing units to big & they are not wired.
I129 02 4/05/10 DT R +INSULATION INSPECTION TIME: 17:00 VRU #: 001904952
4/05/10 AP T /S: 04/05/2010 10:20 AM DJOHNSON
R429 02 4/06/10 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 001905397
4/06/10 DP T /S: 04/05/2010 04:31 PM DJOHNSON
Previous violations # 2,3, &6 were not corrected per code.- -
R429 03 4/08/10 T�I FOUR TRADE FINAL TIME: 17:00 VRU #: 001906437
11.4%/h ` Qt/ " /L T /S: 04/07/2010 12:32 PM RDCONTE
7 COMMENTS AND NOTES
. . . '''' s;. '' _,pr - t r- °. isig§ LE"`; a '�'G'µY +tqe -.av . r ...."" - ^ "": U k- 04"�`RA.'+l°r4"g ' 'fit" ti i 4 F < < 4r
v ,� 'r i4'"aAv R" i;'r'.'
� „
o
+► Via± ' AA: A& 1 S w li& 'i, �, - i
COUNTY OF HARN E TT
0 DEPARTMENT OF BUILDING INSPECTION
AND PLANNING /DEVELOPMENT '
CERTIFICATE OF OCCUPANCY
T his certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in ' 1,>,.
compliance with the various ordinances of the County of Harnett regulating development and building
construction or use. Fo the following:
Use Classification: _ Al Conditional Use Permit No.: �S
Type of Construction: _ Building Permit No.: QN ry
"'• Owner of Building: A M / Electrical Permit No.: i—�
`' Building Address: - C - At 1 . Insulation Permit No.: D
tit
Zoning District: Plumbing Permit No.:
Zoning Permit No.: Mech. Permit No.:
�.,
__Dal //' ' - 1 Envir. C.O. No.: ,
Building Officia Zoning Official 01
t 7 4 4 , T W� 1404® °)4) y i