Loading...
INSPECTIONS PREPARED 11/05/09, 13:58:55 INSPECTION TICKET PAGE 44 Harnett County INSPECTOR: IVR DATE 11/06/09 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 U 6 •9 COMMENTS AND NOTES 1 i PREPARED 11/17/09, 13:59:53 INSPECTION TICKET PAGE 25 Harnett County INSPECTOR: IVR DATE 11/18/09 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC B103 01 11/18/09 TZ R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 I I - 1g - of A814 01 11/18/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 T /S: 11/17/2009 01:28 PM DJOHNSON T /S: 11/17/2009 01:29 PM DJOHNSON COMMENTS AND NOTES PREPARED 11/24/09, 14:00:31 INSPECTION TICKET PAGE 33 Harnett County INSPECTOR: IVR DATE 11/25/09 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP 24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD 3105 01 1 I/ZS,n ` R *OPEN FLOOR VRU #: 001854835 COMMENTS AND NOTES PREPARED 1/08/10, 13:58:37 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 1 /11 /10 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39%34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP 24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD 8105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835 11/25/09 AP R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928 1/06/10 CA R425 02 1 /08 /10 JH FOUR TRADE ROUGH IN VRU #: 001868512 1/08/10 CA T /S: 01/08/2010 10:54 AM JBROCK R425 03 1/11/10 TI FOUR TRADE ROUGH IN VRU #: 001869023 �H n ) COMMENTS AND NOTES PREPARED 1/14/10, 13:58:51 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 1/15/10 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP 24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD B105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835 11/25/09 AP R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928 1/06/10 CA R425 02 1 /08 /10 JH FOUR TRADE ROUGH IN VRU #: 001868512 1 /08 /10 CA T /S: 01/08/2010 10:54 AM JBROCK R425 03 1/11/10 DT FOUR TRADE ROUGH IN VRU #: 001869023 1/11/10 DA 1. No test on pex. 2. B1 trusses not strapped at joint 9 3. Branch drain must extend beyond foundation wall 4. Ladder frame gables. T /S: 01/11/2010 02:11 PM DETAYLOR I129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668 1/13/10 DA Rough in not approved. T /S: 01/13/2010 11:40 AM DETAYLOR R425 04 1/13/10 + FOUR TRADE ROUGH IN VRU #: 001869643 1/13/10 1. Still do not have 100 psi on water lines. T /S: 01/13/2010 11:40 AM DETAYLOR R425 05 1/15/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971 /../c/0 , f T /S: 01/14/2010 09:34 AM DJOHNSON COMMENTS AND NOTES P REPARED 1/12/10, 14:00:07 INSPECTION TICKET PAGE 17 Harnett County INSPECTOR: IVR DATE 1/13/10 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X .# BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 8101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM, MREARIC 8103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP 24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD B105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835 11/25/09 AP R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928 1/06/10 CA R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512 1/08/10 CA T /S: 01/08/2010 10:54 AN JBROCK R425 03 1/11/10 FOUR TRADE ROUGH IN VRU #: 001869023 1/11/10 DA 1. No test on pex. 2. B1 trusses not strapped at joint 9 3. Branch drain must extend beyond foundation wall 4. Ladder frame gables. T /S: 01/11/2010 02:11 PM DETAYLOR I129 01 (/13 /13/10 TI R *INSULATION INSPECTION VRU #: 001869668 7 i7 R425 04 1/11/10 TI FOUR TRADE ROUGH IN VRU #: 001869643 (/ 11_ • COMMENTS AND NOTES PREPARED 4/05/10, 10:20:33 INSPECTION TICKET PAGE 2 Hai?'ett County INSPECTOR: IVR DATE 4/05/10 ADDRESS : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS T /S: 01/22/2010 11:28 AM SSTEWART R429 01 4/01/10 JH FOUR TRADE FINAL VRU #: 001902998 4/01/10 DP 1)Need receptacle on front of house accessible from grade. 2)Need 2oamp receptacle for microwave. 3)Cleanout to grade & cover with at least 3" of dirt. 4)Label AHU in attic & crawl space. 5)Sleeve refrigerant lines in foundation wall. 6)Breaker for condesing units to big & they are not wired. I129 02 4/05/10 TI INSULATION INSPECTION TIME: 17:00 VRU #: 001904952 / ') - A5: 04/05/2010 10:20 AM DJOHNSON COMMENTS AND NOTES PREPARED 4/05/10, 16:31:31 INSPECTION TICKET PAGE 1 Harnett Eounty INSPECTOR: IVR DATE 4/06/10 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39 7E34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC 8103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP 24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD 8105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835 11/25/09 AP R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928 1/06/10 CA R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512 1/08/10 CA T /S: 01/08/2010 10:54 AM JBROCK R425 03 1 /11 /10 DT FOUR TRADE ROUGH IN VRU #: 001869023 1 /11 /10 DA 1. No test on pex. 2. B1 trusses not strapped at joint 9 3. Branch drain must extend beyond foundation wall 4. Ladder frame gables. T /S: 01/11/2010 02:11 PM DETAYLOR 1129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668 1/13/10 DA Rough in not approved. T /S: 01/13/2010 11:40 AM DETAYLOR R425 04 1/13/10 DT FOUR TRADE ROUGH IN VRU #: 001869643 1/13/10 DP 1. Still do not have 100 psi on water lines. T /S: 01/13/2010 11:40 AM DETAYLOR R425 05 1/15/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971 1/15/10 AP T /S: 01/14/2010 09:34 AM DJOHNSON T /S: January 15, 2010 11:47 AM BSUTTON H824 01 1/21/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001875210 1/21/10 AP T /S: 01/22/2010 11:27 AM SSTEWART CONTINUED ONTO NEXT PAGE PREPARED 4/05/10, 16:31:31 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 4/06/10 ADD1ESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS T /S: 01/22/2010 11:28 AM SSTEWART R429 01 4/01/10 JH FOUR TRADE FINAL VRU #: 001902998 4/01/10 DP ITNeed receptacle on front of house accessible from grade. 2)Need 20amp receptacle for microwave. 3)Cleanout to grade & cover with at least 3" of dirt. *Label AHU in attic & crawl space. Sleeve refrigerant lines in foundation wall. 6)Breaker for condesing units to big & they are not wired. I129 02 4/05/10 DT R +INSULATION INSPECTION TIME: 17:00 VRU #: 001904952 4/05/10 AP T /S: 04/05/2010 10:20 AM DJOHNSON R429 02 4/06/10 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 001905397 (j- y • i p 400 T /S: 04/05/2010 04:31 PM DJOHNSON COMMENTS AND NOTES PREPARED 3/31/10, 13:58:33 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 4/01/10 ADDRESS . : 24; EMMA SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP \/24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD B105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835 11/25/09 AP R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928 1/06/10 CA R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512 1/08/10 CA T /S: 01/08/2010 10:54 AM JEROCK R425 03 1 /11 /10 DT FOUR TRADE ROUGH IN VRU #: 001869023 1 /11 /10 DA 1. No test on pex. 2. B1 trusses not strapped at joint 9 3. Branch drain must extend beyond foundation wall 4. Ladder frame gables. T /S: 01/11/2010 02:11 PM DETAYLOR I129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668 1/13/10 DA Rough in not approved. T /S: 01/13/2010 11:40 AM DETAYLOR R425 04 1/13/10 DT FOUR TRADE ROUGH IN VRU #: 001869643 1/13/10 DP 1. Still do not have 100 psi on water lines. T /S: 01/13/2010 11:40 AM DETAYLOR R425 05 1/15/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971 1/15/10 AP T /S: 01/14/2010 09:34 AM DJOHNSON T /S: January 15, 2010 11:47 AM BSUTTON H824 01 1/21/10 OT fENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001875210 1/21/10 AP T /S: 01/22/2010 11:27 AM SSTEWART T /S: 01/22/2010 11:28 AM SSTEWART CONTINUED ONTO NEXT PAGE PREPARED 3/31/10, 13:58:33 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 4/01/10 ADDRESS . : 24EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMNS INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12- 0555 - - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R429 01 4/01/10 TI �, FOUR TRADE FINAL VRU #: 001902998 j< COMMENTS AND NOTES jPREPJIRED 4/07/10, 13:59:47 INSPECTION TICKET PAGE 17 Harnett=County INSPECTOR: IVR DATE 4/08/10 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : ABC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 09/24/2009 11:21 AM JBROCK - - -- KENLAN FARMS #37 US HWY 401 S TO RIGHT ON MCNEILL HOBBS RD TO LEFT ON WIRE RD PASS JOSEY WILLIAMS ON THE LEFT AND TURN RIGHT ON KENLAN RD T /S: 11/17/2009 01:32 PM DJOHNSON -- * * * * * ** *PREMISE # 55390924 * * * * * ** STRUCTURE: 000 000 39X34 3BDR CRAWL W/ GARAGE FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 11/06/09 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001847210 11/06/09 AP T /S: 11/06/2009 12:45 PM MREARIC B103 01 11/18/09 JH R *BLDG FOUND & TEMP SVC POLE VRU #: 001851856 11/18/09 AP A814 01 11/18/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001851914 11/18/09 AP 24 EMMA CT LINDEN 28356 T /S: 11/18/2009 02:05 PM TWARD 8105 01 11/25/09 DT R *OPEN FLOOR VRU #: 001854835 11/25/09 AP R425 01 1/07/10 TI FOUR TRADE ROUGH IN VRU #: 001867928 1/06/10 CA R425 02 1/08/10 JH FOUR TRADE ROUGH IN VRU #: 001868512 1 /08 /10 CA T /S: 01/08/2010 10:54 AM JBROCK R425 03 1/11/10 DT FOUR TRADE ROUGH IN VRU #: 001869023 1 /11 /10 DA 1. No test on pex. 2. B1 trusses not strapped at joint 9 3. Branch drain must extend beyond foundation wall 4. Ladder frame gables. T /S: 01/11/2010 02:11 PM DETAYLOR I129 01 1/13/10 DT R *INSULATION INSPECTION VRU #: 001869668 1/13/10 DA Rough in not approved. T /S: 01/13/2010 11:40 AM DETAYLOR R425 04 1/13/10 DT FOUR TRADE ROUGH IN VRU #: 001869643 1/13/10 DP 1. Still do not have 100 psi on water lines. T /S: 01/13/2010 11:40 AM DETAYLOR R425 05 1/15/10 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001870971 1/15/10 AP T /S: 01/14/2010 09:34 AM DJOHNSON T /S: January 15, 2010 11:47 AM BSUTTON H824 01 1/21/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001875210 1/21/10 AP T /S: 01/22/2010 11:27 AM SSTEWART T /S: 01/22/2010 11:28 AM SSTEWART CONTINUED ONTO NEXT PAGE /PREPARED 4/07/10, 13:59:47 INSPECTION TICKET PAGE 18 Harnett•County INSPECTOR: IVR DATE 4/08/10 ADDRESS . : 24 EMMA CT SUBDIV: KENLAN FARMS PH1 SET1 41LOTS CONTRACTOR : RBC HOMES INC PHONE : (910) 423 -3555 OWNER . . : ABJ INVESTMENTS LLC PHONE : PARCEL . . : 12 -0555- - -0216- -37- APPL NUMBER: 09- 50022916 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS R429 01 4/01/10 JH FOUR TRADE FINAL VRU #: 001902998 4/01/10 DP 1)Need receptacle on front of house accessible from grade. 2)Need 20amp receptacle for microwave. 3)Cleanout to grade & cover with at least 3" of dirt. 4)Label AHU in attic & crawl space. 5)Sleeve refrigerant lines in foundation wall. 6)Breaker for condesing units to big & they are not wired. I129 02 4/05/10 DT R +INSULATION INSPECTION TIME: 17:00 VRU #: 001904952 4/05/10 AP T /S: 04/05/2010 10:20 AM DJOHNSON R429 02 4/06/10 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 001905397 4/06/10 DP T /S: 04/05/2010 04:31 PM DJOHNSON Previous violations # 2,3, &6 were not corrected per code.- - R429 03 4/08/10 T�I FOUR TRADE FINAL TIME: 17:00 VRU #: 001906437 11.4%/h ` Qt/ " /L T /S: 04/07/2010 12:32 PM RDCONTE 7 COMMENTS AND NOTES . . . '''' s;. '' _,pr - t r- °. isig§ LE"`; a '�'G'µY +tqe -.av . r ...."" - ^ "": U k- 04"�`RA.'+l°r4"g ' 'fit" ti i 4 F < < 4r v ,� 'r i4'"aAv R" i;'r'.' � „ o +► Via± ' AA: A& 1 S w li& 'i, �, - i COUNTY OF HARN E TT 0 DEPARTMENT OF BUILDING INSPECTION AND PLANNING /DEVELOPMENT ' CERTIFICATE OF OCCUPANCY T his certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in ' 1,>,. compliance with the various ordinances of the County of Harnett regulating development and building construction or use. Fo the following: Use Classification: _ Al Conditional Use Permit No.: �S Type of Construction: _ Building Permit No.: QN ry "'• Owner of Building: A M / Electrical Permit No.: i—� `' Building Address: - C - At 1 . Insulation Permit No.: D tit Zoning District: Plumbing Permit No.: Zoning Permit No.: Mech. Permit No.: �., __Dal //' ' - 1 Envir. C.O. No.: , Building Officia Zoning Official 01 t 7 4 4 , T W� 1404® °)4) y i ke :. ,vi.y., .. .IVJ•ry b '. re•t::Jr.,‘ ; %rc,i -. $ •3 c r ,t ', ;,.. t.i