Loading...
INSPECTIONS PREPARED 2/09/10, 13:58:02 INSPECTION TICKET PAGE 29 Harnett County INSPECTOR: IVR DATE 2/10/10 'ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39X56 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2.//0//0 07 COMMENTS AND NOTES PREPARED 2/12/10, 13:58:10 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 2/15/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39X56 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP B103 01 2/15/10 TI R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2.1510 ' or T /S: 02/12/2010 12:30 PM NTART COMMENTS AND NOTES & PREPARED 2/16/10, 13:59:34 INSPECTION TICKET PAGE 25 Harnett County INSPECTOR: IVR DATE 2/17/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39856 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP B103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S: 02/12/2010 12:30 PM NTART A814 01 2/17/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 T /S: 02/16/2010 11:01 AM VBROWN P309 01 2/17/10 TI R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 a/( - ,(0 4 p bj T /S: 02/16/2010 11:01 AM VBROWN COMMENTS AND NOTES PREPARED 2/18/10, 13:58:59 INSPECTION TICKET PAGE 37 Harnett County INSPECTOR: IVR DATE 2/19/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39106 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SPD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP 3103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S: 02/12/2010 12:30 PM NTART A814 01 2/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN 40 ORCHARD FALLS DR LOT 539 SPRING LAKE 28390 T /S: 02/17/2010 03:50 PM TWARD P309 01 2/17/10 DT R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN B111 01 2/19/10 TI R *BLDG SLAB INSP VRU #: 001884923 ai 9-l b COMMENTS AND NOTES PREPARED 3/22/10, 14:02:42 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 3/23/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39X56 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING'' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP 8103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S: 02/12/2010 12:30 PM NTART A814 01 2/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN 40 ORCHARD FALLS DR LOT 539 SPRING LAKE 28390 T /S: 02/17/2010 03:50 PM TWARD P309 01 2/17/10 DT R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN B111 01 2/19/10 JH R *BLDG SLAB INSP VRU #: 001884923 2/19/10 AP R425 01 3/17/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001895408 3/17/10 CA T /S: 03/16/2010 09:06 AM VBROWN T /S: 03/17/2010 08:34 AM NTART T /S: 03/17/2010 08:34 AM NTART PER JOHN - R425 02 3 23/10 1 Y FOUR TRADE ROUGH IN VRU #: 001898261 Sea -,0 COMMENTS AND NOTES PREPARED 3/24/10, 13:58:12 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 3/25/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39X56 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP B103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S: 02/12/2010 12:30 PM NTART A814 01 2/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN 40 ORCHARD FALLS DR LOT 539 SPRING LAKE 28390 T /S: 02/17/2010 03:50 PM TWARD P309 01 2/17/10 DT R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN B111 01 2/19/10 JH R *BLDG SLAB INSP VRU #: 001884923 2/19/10 AP R425 01 3/17/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001895408 3/17/10 CA T /S: 03/16/2010 09:06 AM VBROWN T /S: 03/17/2010 08:34 AM NTART T /S: 03/17/2010 08:34 AM NTART PER JOHN R425 02 3/23/10 - FOUR TRADE ROUGH IN VRU #: 001898261 3/23/10 DA 1. Need I joist framing plan and cut sheets. 2. Firecaulk receptacle wire for upstairs bath (hall) 3. Repair framing around fireplace. 4. Need engineering on change of framing around stairway. Plan calls for double 14 " LVL at rear and double 2x10 on side for I joist support. 5. No midstory guides on plumbing downstairs. 6.Install flashing behind housewrap and out over brick for veneer. DO not side or insulate R425 03 3/25/10 TI FOUR TRADE ROUGH IN VRU #: 001899822 3ps7o AP V COMMENTS AND NOTES PREPARED 3/29/10, 13:58:34 INSPECTION TICKET PAGE 17 Harnett County INSPECTOR: IVR DATE 3/30/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39X56 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP B103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S: 02/12/2010 12:30 PM NTART A814 01 2/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN 40 ORCHARD FALLS DR LOT 539 SPRING LAKE 28390 T /S: 02/17/2010 03:50 PM TWARD P309 01 2/17/10 DT R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN B111 01 2/19/10 JH R *BLDG SLAB INSP VRU #: 001884923 2/19/10 AP R425 01 3/17/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001895408 3/17/10 CA T /S: 03/16/2010 09:06 AM VBROWN T /S: 03/17/2010 08:34 AM NTART T /S: 03/17/2010 08:34 AM NTART PER JOHN R425 02 3/23/10 BS FOUR TRADE ROUGH IN VRU #: 001898261 3/23/10 DA 1. Need I joist framing plan and cut sheets. 2. Firecaulk receptacle wire for upstairs bath (hall) 3. Repair framing around fireplace. 4. Need engineering on change of framing around stairway. Plan calls for double 14 " LVL at rear and double 2x10 on side for I joist support. 5. No midstory guides on plumbing downstairs. 6.Install flashing behind housewrap and out over brick for veneer. DO not side or insulate R425 03 3/25/10 DT FOUR TRADE ROUGH IN VRU #: 001899822 3/25/10 AP I129 01 3/30/10 TI R *INSULATION INSPECTION VRU #: 001900968 3 -79 -PO fdl' COMMENTS AND NOTES PREPARED 5/12/10, 14:17:02 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 5/13/10 ADDRESS . : 40 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39X56 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE FLOOD ZONE X # BEDROOMS • 3000.00.00 PROPOSED USE • SFD SEPTIC - EXISTING WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP .._, B103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S• 02/12/2010 12:30 PM NTART A814 01 2/17/10 TW DRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN 40 ORCHARD FALLS DR LOT 539 SPRING LAKE 28390 T /S: 02/17/2010 03:50 PM TWARD P309 01 2/17/10 DT R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN B111 01 2/19/10 JH R *BLDG SLAB INSP VRU #: 001884923 2/19/10 AP R425 01 3/17/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001895408 3/17/10 CA T /S: 03/16/2010 09:06 AM VBROWN T /S: 03/17/2010 08:34 AM NTART T /S: 03/17/2010 08:34 AM NTART PER JOHN R425 02 3/23/10 BS FOUR TRADE ROUGH IN VRU #: 001898261 3/23/10 DA 1. Need I joist framing plan and cut sheets. 2. Firecaulk receptacle wire for upstairs bath (hall) 3. Repair framing around fireplace. 4. Need engineering on change of framing around stairway. Plan calls for double 14 " LVL at rear and double 2x10 on side for I joist support. 5. No midstory guides on plumbing downstairs. 6.Install flashing behind housewrap and out over brick for veneer. DO not side or insulate R425 03 3/25/10 DT FOUR TRADE ROUGH IN VRU #: 001899822 3/25/10 AP I129 01 3/30/10 JH R *INSULATION INSPECTION VRU #: 001900968 3/30/10 AP R429 01 5/13/10 T FOUR TRADE FINAL VRU #: 001925130 .S COMMENTS AND NOTES PREPARED 5/13/10, 14:02:33 INSPECTION TICKET PAGE 13 Harnett Ccjunty INSPECTOR: IVR DATE 5/14/10 ADDRESS . : 40. ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486 -4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01- 0535 -17- -0100- -03- APPL NUMBER: 10- 50023539 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/07/2010 08:38 AM JBROCK - - -- HWY 27 TO NURSERY RD TO RAY RD TO ANDERSON CREEK LOT 539 STRUCTURE: 000 000 39856 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE - SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/10/10 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001881135 2/10/10 AP B103 01 2/15/10 DT R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001882893 2/15/10 AP T /S: 02/12/2010 12:30 PM NTART A814 01 2/17/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001883776 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN 0 0 ORCHARD FALLS DR LOT 539 SPRING LAKE 28390 T /S: 02/17/2010 03:50 PM TWARD P309 01 2/17/10 DT R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001883768 2/17/10 AP T /S: 02/16/2010 11:01 AM VBROWN B111 01 2/19/10 JH R *BLDG SLAB INSP VRU #: 001884923 2/19/10 AP R425 01 3/17/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001895408 3/17/10 CA T /S: 03/16/2010 09:06 AM VBROWN T /S: 03/17/2010 08:34 AM NTART T /S: 03/17/2010 08:34 AM NTART PER JOHN R425 02 3/23/10 BS FOUR TRADE ROUGH IN VRU #: 001898261 3/23/10 DA 1. Need I joist framing plan and cut sheets. 2. Firecaulk receptacle wire for upstairs bath (hall) 3. Repair framing around fireplace. 4. Need engineering on change of framing around stairway. Plan calls for double 14 " LVL at rear and double 2x10 on side for I joist support. 5. No midstory guides on plumbing downstairs. 6.Install flashing behind housewrap and out over brick for veneer. DO not side or insulate R425 03 3/25/10 DT FOUR TRADE ROUGH IN VRU #: 001899822 3/25/10 AP I129 01 3/30/10 JH R *INSULATION INSPECTION VRU #: 001900968 3/30/10 AP R429 01 5/13/10 BS FOUR TRADE FINAL VRU #: 001925130 5/13/10 DP Electrical incomplete. $50 re fee Can lights in master not trimmed. 2. Receptascle missing on rear of house. 3. No light fixture in stairway. R429 02 5/14/10 TI FOUR TRADE FINAL VRU #: 001926278 t y '1" l � F p� 1 N COMMENTS AND NOTES 7f:: i ! ,:" . :-:: 7- rc'];;'i 1- : 1 '(.'( . .r:. , Wg;'.' 0E4 or) k: ka , i t.40 , 12 0 1.M : ii 4 , flittaaVh (0.4i(VighlthtVa l°1 ,. - 74 County of Harnett litiildittg , _ ' „ — • Certificate of Compliance- Jt'Occupancy- . : Certificate issued pursuant to ' the requirements of North Carolina General Statute I 53A-363 and Harnett I.0 County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the .' ■I various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: R- "s Permit Numbers ri ,, Name:Afroiarsrui cris g Part hew,. Building:Jr) -ir n 2 '3 4 3 9 4 Electrical: t t i le Address: 1 -1 n r> rc Lard Fa 1 /5 Insulation: Plumbing: Mechanical: K MFG Home: I e I . plii: , .., . I Date: 5- - 1 0 Building Official:, 9th c j P N.049/744 )C , t . , -1 ofoikatticteuntait,4ffiioti,iftwat f t.,t;:t.“4:t“;.t1 4.3 -,,,t,3.:.;