Loading...
INSPECTIONS '''PREPARED 2/11/10, 14:01:31 INSPECTION TICKET PAGE 36 Harnett County INSPECTOR: IVR DATE 2/12/10 ADDRESS 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JEROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE - • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING'. • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 z - i z )n AP - Mg, COMMENTS AND NOTES PREPARED 2/17/10, 14:16:57 INSPECTION TICKET PAGE 35 Harnett County INSPECTOR: IVR DATE 2/18/10 ADDRESS . : 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC B103 01 2/18/10 TI R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2.-/A40 /11 -Atg T /S: 02/17/2010 12:02 PM DJOHNSON COMMENTS AND NOTES PREPARED 2/24/10, 14:13:16 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 2/25/10 ADDRESS . : 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC B103 01 2/18/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2/18/10 AP T /S: 02/17/2010 12:02 PM DJOHNSON T /S: 02/18/2010 11:10 AM MREARIC P309 01 2/25/10 TI% ' R *PLUMB UNDER SLAB VRU #: 001886962 COMMENTS AND NOTES ' --jam PREPARED 2/26/10, 14:26:40 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 3/01/10 ADDRESS . ■ 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC B103 01 2/18/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2/18/10 AP T /S: 02/17/2010 12:02 PM DJOHNSON T /S: 02/18/2010 11:10 AM MREARIC P309 01 2/25/10 FS R *PLUMB UNDER SLAB VRU #: 001886962 2/25/10 AP T /S: 02/25/2010 03:14 PM FSPIVEY B111 01 3/01/10 TI R *BLDG SLAB INSP VRU #: 001888103 3 ( I � COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DA'Z'E: 03 -01 -10 PERMIT # 10- 50023638 ADDRESS: 1792 tingen VIOLATIONS: 1. R1102.2.7 requires R -5 insulation at perimeters Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 3/01/10, 13:59:47 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 3/02/10 ADDRESS . : 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC B103 01 2/18/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2/18/10 AP T /S: 02/17/2010 12:02 PM DJOHNSON T /S: 02/18/2010 11:10 AM MREARIC P309 01 2/25/10 FS R *PLUMB UNDER SLAB VRU #: 001886962 2/25/10 AP T /S: 02/25/2010 03:14 PM FSPIVEY B111 01 3/01/10 MR R *BLDG SLAB INSP VRU #: 001888103 3/01/10 DA T /S: 03/01/2010 11:40 AM MREARIC perimeter insulation required A814 01 3/02/10 FB ADDRESS CONFIRMATION VRU #: 001886971 2/26/10 AP T /S: 02/26/2010 03:26 PM FBURGESS 1792 TINGEN RD BROADWAY, NC 27505 LOT 12 B111 02 3/02/10 TI R *BLDG SLAB INSP VRU #: 001889255 _/Z.1C7 - COMMENTS AND NOTES PREPARED- 3/16/10, 13:58:36 INSPECTION TICKET PAGE 37 Harncstt County INSPECTOR: IVR DATE 3/17/10 ADDRESS . : 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE S. DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING? • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC 3103 01 2/18/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2/18/10 AP T /S: 02/17/2010 12:02 PM DJOHNSON T /S: 02/18/2010 11:10 AM MREARIC P309 01 2/25/10 FS R *PLUMB UNDER SLAB VRU #: 001886962 2/25/10 AP T /S: 02/25/2010 03:14 PM FSPIVEY B111 01 3/01/10 MR R *BLDG SLAB INSP VRU #: 001888103 3/01/10 DA T /S: 03/01/2010 11:40 AM MREARIC perimeter insulation required A814 01 3/02/10 FB ADDRESS CONFIRMATION VRU #: 001886971 2/26/10 AP T /S: 02/26/2010 03:26 PM FBURGESS 1792 TINGEN RD BROADWAY, NC 27505 LOT 12 B111 02 3/02/10 MR R *BLDG SLAB INSP VRU #: 001889255 3/02/10 AP T /S: 03/02/2010 12:24 PM MREARIC R425 01 3/17/10 TI FOUR TRADE ROUGH IN VRU #: 001895471 -; 17 rn f PcfrZ COMMENTS AND NOTES 1 HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910- 893 -7525 DO NOT REMOVE DA'Z'E: 03 -17 -10 PERMIT # 09- 50023638 ADDRESS: 1792 tingen VIOLATIONS: 1. Fireblock at ceiling junction in garage .. check perimeter 2. Boots are not on roof, and felt is missing in spots 3. Fireblock and caulk over fireplace 4. Air connectors on exhaust fans are not to exceed 14' in length 5. At all breaks in top plate , add splice plates and nail it per R602.6.1 Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 3/18/10, 14:47:51 INSPECTION TICKET - PAG Harnett County INSPECTOR: IVR DA T ADDRESS . : 1792 TINGEN RD SUBDIV: / CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 - AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3000000.00 PROPOSED USE : SFD SEPTIC - EXISTING' NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION (C l� cs Q TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC B103 01 2/18/10 MR R *BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2/18/10 AP T /S: 02/17/2010 12:02 PM DJOHNSON T /S: 02/18/2010 11:10 AM MREARIC P309 01 2/25/10 FS R *PLUMB UNDER SLAB VRU #: 001886962 2/25/10 AP T /S: 02/25/2010 03:14 PM FSPIVEY B111 01 3/01/10 MR R *BLDG SLAB INSP VRU #: 001888103 3/01/10 DA T /S: 03/01/2010 11:40 AM MREARIC perimeter insulation required A814 01 3/02/10 FE ADDRESS CONFIRMATION VRU #: 001886971 2/26/10 AP T /S: 02/26/2010 03:26 PM FBURGESS 1792 TINGEN RD BROADWAY, NC 27505 LOT 12 B111 02 3/02/10 MR R *BLDG SLAB INSP VRU #: 001889255 3/02/10 AP T /S: 03/02/2010 12:24 PM MREARIC R425 01 3/17/10 1 : " FOUR TRADE ROUGH IN VRU #: 001895471 3/17/10 Gip T /S: 03/17/2010 02:11 PM MREARIC 1. fireblock at ceiling in garage at perimeter 2. install boots on roof and shingles 3. firecaulk over fireplace 4. air connectors on exhaust fans... maximum run of 14' 5. at all breaks in top plate, install splice plates per R602.6.1 and nail per code I129 01 3/19/10 TI R *INSULATION INSPECTION VRU #: 001896880 R425 02 3/19/10 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001897339 3 AP MR■ T /S: 03/18/2010 02:47 PM NTART COMMENTS AND NOTES PREPPS2ED /04/10, _14:05:39 INSPECTION TICKET PAGE 13 Harnett County t � INSPECTOR: IVR DATE 5/05/10 ADDRESS . :'1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/20/2010 09:39 AM JBROCK - - -- HWY 27 W TO TINGEN RD TO LOT 12 SUNSET RIDGE STRUCTURE: 000 000 60X32 3BDR SLAB W/ GARAGE & DECK FLOOD ZONE FLOOD ZONE X # BEDROOMS 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 2/12/10 MR R *BLDG FOOTING / TEMP SVC POLE VRU #: 001882092 2/12/10 AP T /S: 02/12/2010 11:52 AM MREARIC B103 01 2/18/10 MR R*ELDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 001884527 2/18/10 AP T /S: 02/17/2010 12:02 PM DJOHNSON T /S: 02/18/2010 11:10 AM MREARIC P309 01 2/25/10 FS R *PLUMB UNDER SLAB VRU #: 001886962 2/25/10 AP T /S: 02/25/2010 03:14 PM FSPIVEY B111 01 3/01/10 MR R *BLDG SLAB INSP VRU #: 001888103 3/01/10 DA T /S: 03/01/2010 11:40 AM MREARIC perimeter insulation required A814 01 3/02/10 FB ADDRESS CONFIRMATION VRU #: 001886971 2/26/10 AP j T /S: 02/26/2010 03:26 PM FBURGESS '11792 TINGEN RD BROADWAY, NC 27505 LOT 12 B111 02 3/02/10 MR R *BLDG SLAB INSP VRU #: 001889255 3/02/10 AP T /S: 03/02/2010 12:24 PM MREARIC R425 01 3/17/10 MR FOUR TRADE ROUGH IN VRU #: 001895471 3/17/10 DA T /S: 03/17/2010 02:11 PM MREARIC 1. fireblock at ceiling in garage at perimeter 2. install boots on roof and shingles 3. firecaulk over fireplace 4. air connectors on exhaust fans... maximum run of 14' 5. at all breaks in top plate, install splice plates per R602.6.1 and nail per code I129 01 3/19/10 MR R *INSULATION INSPECTION VRU #: 001896880 3/19/10 AP T /S: 03/19/2010 12:57 PM MREARIC R425 02 3/19/10 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001897339 3/19/10 AP T /S: 03/18/2010 02:47 PM NTART T /S: 03/19/2010 12:59 PM MREARIC H824 01 4/12/10 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 001908409 5/03/10 AP v/ OLIVER TOLKSDORF PUMP & ALARM TO BE CHECKED BEFORE OPERATIONS TO BE ISSUED. T /S: 04/12/2010 09:07 AM SSTEWART T /S: 04/12/2010 09:09 AM SSTEWART T /S: 05/04/2010 10:33 AM SSTEWART R429 01 4/30/10 TI FOUR TRADE FINAL VRU #: 001918768 4/29/10 CA T /S: 04/29/2010 03:11 PM NTART CANCELLED FINAL FOR FRIDAY NO OPERATIONS PERMIT R429 02 5/05/10 TI FOUR TRADE FINAL VRU #: 001920577 CONTINUED ONTO NEXT PAGE PREPARED 5/04/10, 14:05:39 INSPECTION TICKET PAGE 14 Harnett County - INSPECTOR: IVR DATE 5/05/10 ADDRESS . : 1792 TINGEN RD SUBDIV: CONTRACTOR : WEAVER DEVELOPMENT CO INC PHONE : (910) 433 -0888 OWNER . . : WEAVER DEVELOPMENT CO INC PHONE : (910) 630 -2100 PARCEL . : 03- 9587 -01- -0020- -12- APPL NUMBER: 10- 50023638 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED ,g RESULT RESULTS /COMMENTS 5- 5-10 COMMENTS AND NOTES • . , ' . • • • t " " (: hi&.oghi,highti.,.,hi.s44..,40:,,k . County of Harnett -.. Building Inspections Department . . r enqiur ni requirements Plann the North .5e thh Ser ce Carolina :n, p . s pursuant County e lf ns a : St G a e te ne B r u a i l ld S For the an hefo d ll H ow am il e g t : I Use Classification: R 4 Electrical: . -5 A u e r DPMeirl Q int Permit Numbers Name: I /ea Building: JO - S COY 34.3e o Certificate I Compliance:x Octunancy:L%_ bi Certific issued i t n a g t::te od l e 5 s 3 . A re County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the , Address: 1 7 9 2- - 7 - 1 la , P 1.1. R et Insulation: 0 Plumbing: 0 4 i Mechanical: 1 MFG Home: Date: 5- 5.. 10 Building Official: 7. Raw, A;oi i, . t, 1 7 T 7 . TV ' (4 Y‘ ( a) .(al I fa) '7 .fa) ; .. , • • ; :, •:4., s.# t •', ,•••t t., . • • , ,' 4., ,. ., • . • 4 . i