Loading...
IPACHTE# /3 sJJQV Harnett County Department of Public Health hDrovement Permit 27469 A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: AI/ C -- -b/-. ISSUED TO: k1r SUBDIVISION LOT # /C6 NEW ✓❑" REPAIR ❑ f EXPANSION El Site Improvements required prior to Construction Authorization Issuance: Type of Structure: S'F S" X z i Proposed Wastewater System Type: i�y�p -t Q sUQs- :t3A %4f- Projected Daily Flow: C9 O Cl GPD Number of bedrooms: Number of Occupants: _max Basement ❑Yes [?"-No Pump Required: N es ❑ No ❑ MMax be required based on final location and elevations of facilities Type of Water Supply: El Community L� Public ❑ Well Distance from well feet Permit valid for: 21IF-1ve years Permit conditions: ❑ No expiration Authorized State Agent:: `2,, r . /� %w� �C�/ f Date: S`��5��2 ot? SEE ATTACHED SITE SKETCH The issuance of this permit by t e Heart m no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: Saj—&• PROPERTY LOCATION: SUBDIVISION S,Xf LOT # /6e Facility Type: ���� 2"'New ❑ Expansion ❑ Repair T Basement? ❑ Yes Q'-No Basement Fixtures? ❑ Yes ❑ No Type of Wastewater System ** o� S`�) .x .�t�¢,•. (Initial) Wastewater Flow: iQw GPD (See note below, if applicable Pr o25' (Repair) Installation Requirements /Conditions Number of trenches 3 Septic Tank Size 105­0 gallons Exact length of each trench 8(3 feet Trench Spacing: 9 Feet on Center Pump Tank Size / OQ 0 gallons Trenches shall be installed on contour at a Soil Cover: /8- 6 inches Maximum Trench Depth of: 3Q-/8 inches (Maximum soil cover shall not exceed (Trench bottoms shall be level to +/ -1/4" 36" above the trench bottom) in all directions) Pump Requirements: ft. TDH vs. GPM inches below pipe Aggregate Depth: inches above pipe Conditions: 5�--� 1 ��, ok + r�-� }. 18" inches total WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. * *If applicable: /understand the sr stem type pecified is different from the type specified on the app lication. / accept the specifcationf of this permit. Owner /Legal Representative Signature: Date: This Construction Authorization is subiect to revocation if the site Dian. Dlat or the intended use chances. The Construction Authorization shall not he transferred when there is a chance in nwnerchin of the site This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Authorized State ram /C/c Treatment and Disposal and to the conditions of this permit Date: Construction Authorization Expiration Date: 2C /-7 SEE ATTACHED SITE SKETCH ,o Ise 1 1 1 / Ll.Off, 3t tJr; ✓e 0 / 9k, Department of Environment, Health and Natural Resources Division of Environmental Health On -Site Wastewater Section SOIL /SITE EVALUATION for ON -SITE WASTEWATER SYSTEM Owner: Applicant: Address: Date Evaluated:.) -4.e 2-1117 Proposed Facility: Design Flow (.1949): Location of Site: Property Recorded: Water Supply: []Public[] Individual ❑ Well Evaluation Method: Auger Bo i g ❑Pit ❑Cut Type of Wastewater: a Sewage ❑ Industrial Process Sheet: Property ID: Lot #: File #: Code: Property Size: ❑ Spring ❑ Other ❑ Mixed P R O F I L E # .1940 Landscape Position/ Slope % Horizon Depth (In.) SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS Profile Class & LTAR .1941 Structure/ Texture .1941 Consistence Mineralogy .1942 Soil Wetness/ Color .1943 Soil Depth (IN.) .1956 Sapro Class .1944 Restr Horiz ev G-7c) �Lfn�l�✓O f - G WV-'VVwP Description Initial System Repair System Other Factors (.1946): Site Classification (.1948): S Evaluated By: /Q Others Present: Available Space (.1945) ✓ System Type(s) DT v j` Site LTAR .8 ev