Loading...
INSPECTIONS PREPARED 12/21/09, 14:36:13 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 12/22/09 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 *530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 46X56 3BDR 2BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE - SFD SEPTIC - EXISTING' SEWER WATER SUPPLY COUNTY . PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 TI R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 ii 1 ffP bj COMMENTS AND NOTES PREPARED 1/06/10, 14:21:04 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 1/07/10 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 #530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 32.6X52 3BDR 2.5BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 12/22/09 AP B103 01 �a "43_,C 1/07/1 R *BLDG FOUND & TEMP SVC POLE VRU #: 001867590 q COMMENTS AND NOTES PREPARED 1/14/10, 13:58:51 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 1/15/10 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 #530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 32.6X52 3BDR 2.5BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 12/22/09 AP B103 01 1/07/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001867590 1/07/10 AP T /S: January 07, 2010 11:43 AM BSUTTON A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868363 1/07/10 AP T /S: 01/06/2010 02:20 PM RDCONTE 30 ROCKINGHAM ST LOT 530 SPRING LAKE 28390 T /S: 01/07/2010 10:20 AM TWARD 8105 01 1/ 15/10 TI / —� R *OPEN FLOOR VRU #: 001870531 i e COMMENTS AND NOTES PREPARED 1/28/10, 13:59:22 INSPECTION TICKET PAGE 33 Harnett County INSPECTOR: IVR DATE 1/29/10 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 #530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 32.6X52 3BDR 2.5BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 12/22/09 AP B103 01 1/07/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001867590 1/07/10 AP T /S: January 07, 2010 11:43 AM BSUTTON A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868363 1/07/10 AP T /S: 01/06/2010 02:20 PM RDCONTE 30 ROCKINGHAM ST LOT 530 SPRING LAKE 28390 T /S: 01/07/2010 10:20 AM TWARD B105 01 1/15/10 JH R *OPEN FLOOR VRU #: 001870531 1/15/10 AP R425 01 1/2 - 10 ii17 FOUR TRADE ROUGH IN VRU #: 001876875 �� COMMENTS AND NOTES PREPARED 2/12/10, 13:58:10 INSPECTION TICKET PAGE 25 Harnett County INSPECTOR: IVR DATE 2/15/10 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 #530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 32.6X52 3BDR 2.5BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 12/22/09 AP B103 01 1/07/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001867590 1/07/10 AP T /S: January 07, 2010 11:43 AM BSUTTON A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868363 1/07/10 AP T /S: 01/06/2010 02:20 PM RDCONTE 30 ROCKINGHAM ST LOT 530 SPRING LAKE 28390 T /S: 01/07/2010 10:20 AM TWARD B105 01 1/15/10 JH R *OPEN FLOOR VRU #: 001870531 1/15/10 AP R425 01 1/29/10 FOUR TRADE ROUGH IN VRU #: 001876875 1/29/10 DA 1. COmplete roofing, no roof boots /wall flashing not installed. 2. Install front and rear doors. 3. Nail osb O joint blocking 6 "oc around entire house 4. Need engineering on steel beam- size- end load- jack stud requirement. Beam is covered. 12" x weight? Plan is shown w/ BCI I joists. Engineer also must verify that footing is sufficient to carry steel beam load points. DO NOT SIDE -ok to insulate I129 01 2/01/10 DT R *INSULATION INSPECTION VRU #: 001876884 2/02/10 CA Per Kevin T /S: 02/02/2010 10:04 AM DETAYLOR R425 02 2/01/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001878669 2/02/10 CA T /S: 01/29/2010 02:32 PM NTART I129 02 2/08/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001880327 2/08/10 CA T /S: 02/05/2010 11:41 AM VBROWN T /S: 02/08/2010 10:10 AM JBROCK R425 03 2/08/10 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001880319 2/08/10 CA T /S: 02/05/2010 11:41 AM VBROWN T /S: 02/08/2010 10:10 AM JBROCK 1129 03 2/15/10 TI R *INSULATION INSPECTION VRU #: 001882752 i /is7 (o 4 R425 04 2/15/10 TI FOUR TRADE ROUGH IN VRU #: 001882745 COMMENTS AND NOTES PFAPAREU 4/14/10, 8:11:53 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/14/10 v. ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 4530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 32.6X52 3BDR 2.5BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 3101 01 12/22/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 12/22/09 AP B103 01 1/07/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001867590 1/07/10 AP T /S: January 07, 2010 11:43 AM BSUTTON A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868363 1/07/10 AP T /S: 01/06/2010 02:20 PM RDCONTE 30 ROCKINGHAM ST LOT 530 SPRING LAKE 28390 T /S: 01/07/2010 10:20 AM TWARD B105 01 1/15/10 JH R *OPEN FLOOR VRU #: 001870531 1/15/10 AP R425 01 1/29/10 BS FOUR TRADE ROUGH IN VRU #: 001876875 1/29/10 DA 1. COmplete roofing, no roof boots /wall flashing not installed. 2. Install front and rear doors. 3. Nail osb @ joint blocking 6 "oc around entire house 4. Need engineering on steel beam- size- end load- jack stud requirement. Beam is covered. 12" x weight? Plan is shown w/ BCI I joists. Engineer also must verify that footing is sufficient to carry steel beam load points. DO NOT SIDE -ok to insulate I129 01 2/01/10 DT R *INSULATION INSPECTION VRU #: 001876884 2/02/10 CA Per Kevin T /S: 02/02/2010 10:04 AM DETAYLOR R425 02 2/01/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001878669 2/02/10 CA T /S: 01/29/2010 02:32 PM NTART I129 02 2/08/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001880327 2/08/10 CA T /S: 02/05/2010 11:41 AM VBROWN T /S: 02/08/2010 10:10 AM JBROCK R425 03 2/08/10 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001880319 2/08/10 CA T /S: 02/05/2010 11:41 AM VBROWN T /S: 02/08/2010 10:10 AM JBROCK 1129 03 2/15/10 DT R *INSULATION INSPECTION VRU #: 001882752 2/15/10 AP R425 04 2/15/10 DT FOUR TRADE ROUGH IN VRU #: 001882745 2/15/10 DA Still waiting for engineered repair. Per Ken, house okay to CONTINUED ONTO NEXT PAGE d PREPARE? 4/14/10, 8:11:53 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 4/14/10 ADDRECS '. : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS be sided and sheetrocked, however, stud columns must be left exposed. T /S: 02/15/2010 10:37 AM DETAYLOR B101 02 3/26/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001900299 3/26/10 CA T /S: 03/25/2010 10:42 AM NTART per Kevin6 /2010 01:04 PM JHALL B101 03 3/30/10 RD R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001901701 3/30/10 CA T /S: 03/29/2010 08:50 AM RDCONTE CONTRACTOR WILL MEET ON SITE T /S: 03/30/2010 10:01 AM RDCONTE JIMMY CALLED TO CANCEL B101 04 4/14/10 TI R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001909944 Lf (yiQ T /S: 04/14 2010 08:11 AM VBROWN 1 (COMMENT AN NOTES 7 / < ,• DICK COKENE1E sUB / 3. 24' 3' = SDI . COSTING STEEL BENZ 11200 = 11E1 txr FOOTING TO BE INSTALLED BMA/ MISING FOOTING, TYP. T \ I 1 ' -8 ' II I I .1- 2' 9' 1 2'-I 9' t 2'-f 0 FOUNDATION PLAN N.T.S. 1 , , . 1 1 i 7(1 XIST)NG FOOTING 10" NEW 3'x3'x12" 12" S r 6 EA. #4 BARS E.W k _ 3 , _� � i 20193 e ,P ' GINtY t SECTION 0 FOOTING ,t(- S',�• len mom Coastal Plains Engineering, P.A. MEW CRS RESIDENCE -• Ma + x SKEET NO: MD OMIE MEN ! ® 0811111111131 s1 - PREPARED 4/21/10, 14:02:28 INSPECTION TICKET PAGE 10 Harnett County , _1 INSPECTOR: IVR DATE 4/22/10 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE PARCEL . . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 12/14/2009 12:32 PM VBROWN - - -- ROCKINGHAM STREET, OVERHILLS CREEK SEC 7 #530. 87N, RIGHT ON NURSERY RD, AT CAUTION LIGHT GO STRAIGHT ONTO OVERHILLS RD, OVERHILLS CREEK ENT SIGN IS ON THE RIGTH. STRUCTURE: 000 000 32.6X52 3BDR 2.5BATH SFD W GAR CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS B101 01 12/22/09 DT R *BLDG FOOTING / TEMP SVC POLE VRU #: 001863861 12/22/09 AP B103 01 1/07/10 BS R *BLDG FOUND & TEMP SVC POLE VRU #: 001867590 1/07/10 AP T /S: January 07, 2010 11:43 AM BSUTTON A814 01 1/08/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001868363 1/07/10 AP /S: 01/06/2010 02:20 PM RDCONTE f30 ROCKINGHAM ST LOT 530 SPRING LAKE 28390 T /S: 01/07/2010 10:20 AM TWARD 3105 01 1/15/10 JH R *OPEN FLOOR VRU #: 001870531 1/15/10 AP R425 01 1/29/10 BS FOUR TRADE ROUGH IN VRU #: 001876875 1/29/10 DA 1. COmplete roofing, no roof boots /wall flashing not installed. 2. Install front and rear doors. 3. Nail osb @ joint blocking 6 "oc around entire house 4. Need engineering on steel beam- size- end load- jack stud requirement. Beam is covered. 12" x weight? Plan is shown w/ BCI I joists. Engineer also must verify that footing is sufficient to carry steel beam load points. DO NOT SIDE -ok to insulate I129 01 2/01/10 DT R *INSULATION INSPECTION VRU #: 001876884 2/02/10 CA Per Kevin T /S: 02/02/2010 10:04 AM DETAYLOR R425 02 2/01/10 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001878669 2/02/10 CA T /S: 01/29/2010 02:32 PM NTART I129 02 2/08/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001880327 2/08/10 CA T /S: 02/05/2010 11:41 AM VBROWN T /S: 02/08/2010 10:10 AM JBROCK R425 03 2/08/10 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001880319 2/08/10 CA T /S: 02/05/2010 11:41 AM VBROWN T /S: 02/08/2010 10:10 AM JBROCK I129 03 2/15/10 DT R *INSULATION INSPECTION VRU #: 001882752 2/15/10 AP R425 04 2/15/10 DT FOUR TRADE ROUGH IN VRU #: 001882745 2/15/10 DA Still waiting for engineered repair. Per Ken, house okay to be sided and sheetrocked, however, stud columns must be left CONTINUED ONTO NEXT PAGE :PREPAjED 4/21/10, 14:02:28 INSPECTION TICKET PAGE 11 Harnett County r + INSPECTOR: IVR DATE 4/22/10 ADDRESS . : 30 ROCKINGHAM ST SUBDIV: OVERHILLS CREEK SCT 7 92LOTS CONTRACTOR : REGENCY HOMES PHONE : (910) 424 -0455 OWNER . . : REGENCY HOMES INC PHONE : PARCEL . : 01- 0514 -03- -0006- -29- APPL NUMBER: 09- 50023420 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS exposed. T /S: 02/15/2010 10:37 AM DETAYLOR B101 02 3/26/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001900299 3/26/10 CA T /S: 03/25/2010 10:42 AM NTART per Kevin6 /2010 01:04 PM JHALL B101 03 3/30/10 RD R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001901701 3/30/10 CA T /S: 03/29/2010 08:50 AM RDCONTE CONTRACTOR WILL MEET ON SITE T /S: 03/30/2010 10:01 AM RDCONTE JIMMY CALLED TO CANCEL B101 04 4/14/10 JH R *BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 001909944 4/14/10 AP T /S: 04/14/2010 08:11 AM VBROWN Footing for beam in garage JHALL R429 01 4 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 001913013 y /a -l9 (l T /S: 04/20/2010 08:56 AM NTART ��VV�� COMMENTS AND NOTES r3;*". *:taa/`•at.'sa{ i. *4k•* *t�ii,. a ' : 0•a ‘ :.p a• q p 0 ,,,,,Aiklit l: A ,.. "^ A,.7 b: A '16, �® y A4 4.1 1oil. i hit A`.I.AIYi1 4 ;. 4 COUNTY OF HARNETT :,.‘ DEPARTMENT OF BUILDING INSPECTION AND PLANNING /DEVELOPMENT � ' CERTIFICATE OF OCCUPANCY #k" This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building • Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building ,` O fit construction or use. For the following: Use Classification: PERMIT NUMBERS Owner: ! i - • #ref Building Permit No.: l� �`• 911 Address: - . .. _ A Electrical Permit No.: r� • g:. Insulation Permit No.: O 0 Plumbing Permit No.: ‘..r, ? 1! State: Zip Code: Mech. Permit No.: O■ cj 1'• _ Date: / MFG. Home: rrtr y�Y� y Building • iciiall p ' ;`l �f' '..' I "/ �! �f 441°'‘ ` IV I.' r �i4 ` ° �fl' `i/ s : I '!I r F. r �_•t., t„ r 1 _ t.; e'. . 4;.i Itt.:., 1,,t ro •a e �:- q 3' 11 .'t 0_, F1 'e a,