Loading...
INSPECTIONS PREPARED 2/10/10, 14:09:53 INSPECTION TICKET PAGE Harnett County INSPECTOR: IVR DATE 2/11/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE ®ANDERSON CRK PH3 30L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 210S, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.5BATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE - SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 TII R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 7 -it T /S: 02/10/2010 02:09 PM NTART yV- COMMENTS AND NOTES PRLPARED 2/11/10, 14:01:31 INSPECTION TICKET PAGE 40 Harnett County INSPECTOR: IVR DATE 2/12/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH3 30L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 210S, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.5BATH SFD WITH GAR, SLAB FLOOD ZONE - FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 TI R *BLDG MONOLITHIC SLAB VRU #: 001882133 2 )Z tae COMMENTS AND NOTES SI . REScheck Software Version 4.2.2 Compliance Certificate Li 4 Project Title: Sage Energy Code: 2006 IECC Location: Spring Lake, North Carolina Construction Type: Single Family Conditioned Floor Area: 3144 ft2 Glazing Area Percentage: 8% Heating Degree Days: 3169 Climate Zone: 3 Construction Site: Owner /Agent: Designer /Contractor: 540 Higgrove Dr Spring Lake, NC 28390 Permit # 10- 50023656 .o- ' `n '/ a'. . a x • Vctin r s., L m-e a rx:, r P y , r ��3n. nwr $ , ' f c ,- a ' �'u nm fr s « r , uv.,:z� b .ath.,.t.a.... ` ... - - ...!"" :. ".... ,:z.. : :::6 r4 " „u._ .15. J.: -:-. .,.a i., >5 ftA Compliance: 13.5% Better Than Code Maximum UA: 683 Your UA: 591 Maximum SHGC: 0.40 Your SHGC: 0.28 1•µr tryk�,pnt'oT,j� ^,}t ".+Ci. �Sr:M j :; Z� IVA:± ...V '. C1.9 . 8s i , ICON t Gaa tng0b 111W4 t ,10i j., i i ' Assembly Jr ,� r1 [Area orrr t Valued R ValueV,tor i oor y no y S enmeter U•Factor fin, nicc C r .:. G�,. "st . ... , rw� ..4 , {�. ,.. s� ;., , Ceiling 1: Cathedral Ceiling (no attic) 1062 38.0 0.8 29 '\ Ceiling 2: Flat Ceiling or Scissor Truss 498 38.0 0.8 14 Wall 1: Wood Frame, 16” o.c. 1490 13.0 0.8 98 Window 1: Vinyl Frame:Double Pane with Low -E 230 0.350 81 SHGC: 0.28 /' Door 1: Glass 18 0.350 6 SHGC: 0.28 Door 2: Solid 42 0.500 21 Wall 2: Wood Frame, 16" o.c. 1508 13.0 0.8 124 Floor 1: Slab-On- Grade:Unheated 190 0.0 198 Insulation depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Unconditioned Space 431 19.0 0.8 20 Heat Pump 1: Air Source 7.7 HSPF, 13 SEER Air Conditioner 1: Electric Central Air 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in RES k Version 4.2.2 and to comply with the mandatory requirem s listed i the RE, heck In on heckiist. A NORt MO An/04 -/ J. Name • Title Signature Date Project Title: Sage Report date: 02/12/10 Data filename: C:1Documents and Settings'Bryan \Desktop Res Check Templates \Res check template SAGE.rck Page 1 of 1 • • V ■ C Associates Inc. 2725 E. Millbrook Rd Suite 121 Raleigh, North Carolina 27604 (919) 871 -0999 Fax (919)71 -0335 /' Project: . e P Project Number:. 4/3 3/224 S . ocnr Project: l 1 �y''�` nit/Joe 6/ Z o f y � � Client: s u ' / Day/Date: Fr; z -/ —/0 Location: Temp/Weather 30 / /' (4--/ Type of Inspection: (y)Soils ( )Concrete ( )Structural Steel ( )Asphalt (s)Foundation ( )Masonry ( )Other Arrive I I On -Site Time - Travel Time _ Depart _:_ I _ _ I _ _ Lab Time Total Time No. Trips_ Total Mileage Chargeable Equipment Notes: / / / r� I f [ / : r1 Li'P_Cr r1 /!/ ✓eo / e h S, � I 91 K4 , es - 4,10 obs #r e 4,t ! ev /L �n•�t for ((IF VI 14 1 I.,ove. 0 / 04 A / /r vu1 �L / . I / o1, A Pw l� .07 7l / v! 7 014 a / .a / .f �-/ t/ rri We11 ,/�in ,.tv cob..p(P /P . SO•IS kt t t i t Le wont- re S;Lq/ N,r'rit /ess _ J - I fLaw 6 (:1 yr A'5I1A4tLeJ / VA rr i� 5+-44 prate /'orl fro a e 50 - n -/ (r04451.-t o I�t" Al F4 4 s par4 /Y se. T rri ; 4.1 � So, /5 oft su !"; Y >n/' e [i to / 3 ' rr�rrpnli a t0 .v7i o<,, y �c.o / co! T G n e / a //oo6, / / r L 4/I1 col e•' 47 o / z.occ "Si, =. J r,,, „ CAR0 c ' O ,, s � ! 'k y ' . i Q @ b :� SEAL 034487 • .,1'8 tT L °:".7 r , r, Reviewed By i* Printed Name laior L 7,/,, / s� /Tr This Rcpon is Preliminary until reviewed by the engineering staff. Field Test Data, Locations, Elevations and Depths are Estimated. • PREPARED 3/02/10, 13:59:13 INSPECTION TICKET PAGE 23 Harnett County INSPECTOR: IVR DATE 3/03/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH3 30L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 2105, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.SBATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING'? • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001882133 2/12/10 AP T /S: 02/12/2010 02:48 PM NTART A814 01 2/15/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001882943 2/17/10 AP T /S: 02/12/2010 12:39 PM NTART 540 HIGHGROVE DR LOT 89 SPRING LAKE 28390 T /S: 02/17/2010 03:35 PM TWARD R425 01 3/03/10 TI r � ,1 FOUR TRADE ROUGH IN VRU #: 001889849 .3%7- Sao COMMENTS AND NOTES PREPARED 3/03/10, 14:01:06 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 3/04/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE@ANDERSON CRK PH3 30L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 2105, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.5BATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001882133 2/12/10 AP T /S: 02/12/2010 02:48 PM NTART A814 01 2/15/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001882943 2/17/10 AP T /S: 02/12/2010 12:39 PM NTART 540 HIGHGROVE DR LOT 89 SPRING LAKE 28390 T /S: 02/17/2010 03:35 PM TWARD R425 01 3/03/10 • F UR TRADE ROUGH IN VRU #: 001889849 3/03/10 1) Missing fire caulk throughout house on wires @ top plates. 2)3' head of water on drain line test no water in pipe. t Remove treated 2x4 @ master bath shower. y 2x6 header for 2x8 in upstairs spare bathroom. 5)- R425 02 3/04/10 TI FOUR TRADE ROUGH IN VRU #: 001890169 3 -Q i /O ., // CJ COMMENTS AND NOTES PREPARED 3/08/10, 13:58:54 INSPECTION TICKET PAGE 50 Harnett INSPECTOR: IVR DATE 3/09/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH3 30L CONTRACTOR : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 210S, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.5BATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X ' # BEDROOMS 4.00 PROPOSED USE SFD SEPTIC - EXISTING' - SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001882133 2/12/10 AP T /S: 02/12/2010 02:48 PM NTART A814 01 2/15/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001882943 2/17/10 AP T /S: 02/12/2010 12:39 PM NTART 540 HIGHGROVE DR LOT 89 SPRING LAKE 28390 T /S: 02/17/2010 03:35 PM TWARD R425 01 3/03/10 JH FOUR TRADE ROUGH IN VRU #: 001889849 3/03/10 DA 1) Missing fire caulk throughout house on wires @ top plates. 2)3' head of water on drain line test no water in pipe. 3)Remove treated 2x4 @ master bath shower. 4)replace 2x6 header for 2x8 in upstairs spare bathroom. 5)- R425 02 3/04/10 FOUR TRADE ROUGH IN VRU #: 001890169 3/04/10 !Ii) 3' head of water on drain linesLL I129 01 3/08/10 R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891407 3/08/10 CA T /S: 03/05/2010 11:34 AM DJOHNSON T /S: 03/08/2010 08:15 AM VBROWN ANDREW CALLED AND CAN AND ROLLED OVER FOR TUES. R425 03 3/08/10 VC FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001891415 3/08/10 CA T /S: 03/05/2010 11:35 AM DJOHNSON T /S: 03/08/2010 08:16 AM VBROWN ANDREW CALLED CAN ROLLOVER FOR TUES R425 04 3/09/10 TI FOUR TRADE ROUGH IN VRU #: 001892199 I129 02 3/09/10 T R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891746 Z T /S: 03/08/2010 08:16 AM VBROWN R427 01 3/0 /10 TI ���/// FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001891761 3 - /0 /f f� T /S: 03/08/2010 08:17 AM VBROWN `V COMMENTS AND NOTES PREPARED 3/16/10, 13:58:36 INSPECTION TICKET PAGE 40 Harnett County INSPECTOR: IVR DATE 3/17/10 ADDRESS : 540 HIGHGROVE DR SUBDIV: HIGHGROVE ®ANDERSON CRK PH3 30L CONTRACi4OR :..gAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 2105, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.5BATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001882133 2/12/10 AP T /S: 02/12/2010 02:48 PM NTART A814 01 2/15/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001882943 2/17/10 AP T /S: 02/12/2010 12:39 PM NTART 540 HIGHGROVE DR LOT 89 SPRING LAKE 28390 T /S: 02/17/2010 03:35 PM TWARD R425 01 3/03/10 JH FOUR TRADE ROUGH IN VRU #: 001889849 3/03/10 DA 1) Missing fire caulk throughout house on wires ® top plates. 2)3' head of water on drain line test no water in pipe. 3)Remove treated 2x4 @ master bath shower. 4)replace 2x6 header for 2x8 in upstairs spare bathroom. 5)- R425 02 3/04/10 JH FOUR TRADE ROUGH IN VRU #: 001890169 3/04/10 DA 3' head of water on drain linesLL I129 01 3/08/10 VC R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891407 3/08/10 CA T /S: 03/05/2010 11:34 AM DJOHNSON T /S: 03/08/2010 08:15 AM VBROWN ANDREW CALLED AND CAN AND ROLLED OVER FOR TUES. R425 03 3/08/10 VC FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001891415 3/08/10 CA T /S: 03/05/2010 11:35 AM DJOHNSON T /S: 03/08/2010 08:16 AM VBROWN ANDREW CALLED CAN ROLLOVER FOR TUES R425 04 3/09/10 JH FOUR TRADE ROUGH IN VRU #: 001892199 3/09/10 CA house over 2500 square feet I129 02 3/09/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891746 3/09/10 AP T /S: 03/08/2010 08:16 AM VBROWN R427 01 3/09/10 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001891761 3/09/10 AP T /S: 03/08/2010 08:17 AM VBROWN M305 01 3/17/10 TI _ +. //_ R *PLUMB SEWER CONNECTION VRU #: 001895804 CONTINUED ONTO NEXT PAGE PREPARED 3/16/10, 13:58:36 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 3/17/10 ADDRESS : 540 HIGHGROVE DR SUBDIV: HIGHGROVE ®ANDERSON CRK PH3 30L CONTRACTBR : R,AVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P307 01 3/17/10 TI R *PLUMB WATER CONNECTION VRU #: 001895812 COMMENTS AND NOTES PREPARED 4/01/10, 14:01:15 INSPECTION TICKET PAGE 35 Harnett County INSPECTOR: IVR DATE 4/05/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH3 30L CONTRACTO : SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 210S, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.SBATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001882133 2/12/10 AP T /S: 02/12/2010 02:48 PM NTART A814 01 2/15/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001882943 2/17/10 AP T /S: 02/12/2010 12:39 PM NTART 40 HIGHGROVE DR LOT 89 SPRING LAKE 28390 T /S: 02/17/2010 03:35 PM TWARD R425 01 3/03/10 JH FOUR TRADE ROUGH IN VRU #: 001889849 3/03/10 DA 1) Missing fire caulk throughout house on wires @ top plates. 2)3' head of water on drain line test no water in pipe. 3)Remove treated 2x4 @ master bath shower. 4)replace 2x6 header for 2x8 in upstairs spare bathroom. 5)- R425 02 3/04/10 JH FOUR TRADE ROUGH IN VRU #: 001890169 3/04/10 DA 3' head of water on drain linesLL I129 01 3/08/10 VC R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891407 3/08/10 CA T /S: 03/05/2010 11:34 AM DJOHNSON T /S: 03/08/2010 08:15 AM VBROWN ANDREW CALLED AND CAN AND ROLLED OVER FOR TUES. R425 03 3/08/10 VC FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001891415 3/08/10 CA T /S: 03/05/2010 11:35 AM DJOHNSON T /S: 03/08/2010 08:16 AM VBROWN ANDREW CALLED CAN ROLLOVER FOR TUES R425 04 3/09/10 JH FOUR TRADE ROUGH IN VRU #: 001892199 3/09/10 CA house over 2500 square feet I129 02 3/09/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891746 3/09/10 AP T /S: 03/08/2010 08:16 AM VBROWN R427 01 3/09/10 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001891761 3/09/10 AP T /S: 03/08/2010 08:17 AM VBROWN M305 01 3/17/10 JH R *PLUMB SEWER CONNECTION VRU #: 001895804 3/17/10 AP CONTINUED ONTO NEXT PAGE PREPARED 4/01/10, 14:01:15 INSPECTION TICKET PAGE 36 Harnett County INSPECTOR: IVR DATE 4/05/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH3 30L CONTRACTORr: SAVVY HOMES, LLC PHONE . (919) 787 -5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P307 01 3/17/10 JH R *PLUMB WATER CONNECTION VRU #: 001895812 3/17/10 AP R431 01 ( 4/005/10 TI _ FOUR TRADE FINAL >2500 VRU #: 001904101 7 Sig P - b��a // I A klattek . a dre , Afln: jKy! / 004 4,-nu 49 i( � a COMMENTS AND NOTES PREPARED 4/06/10, 13:58:26 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 4/07/10 ADDRESS . : 540 HIGHGROVE DR SUBDIV: HIGHGROVEOANDERSON CRK PH3 30L CONTRACTOR'": SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T /S: 01/28/2010 09:57 AM VBROWN - - -- HIGHGROVE AT ANDERSON CREEK SUB DIV PH II. 540 HIGHGROVE DRIVE. 2105, RIGHT ON RAY RD, SUB DIV WILL BE ON YOUR LEFT, LEFT ONTO HIGHGROVE DRIVE. STRUCTURE: 000 000 50X57 4BDR 2.5BATH SFD WITH GAR, SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY - COUNTY PERMIT: CPSF 00 CP * SPD REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P309 01 2/11/10 KS R *PLUMB UNDER SLAB TIME: 17:00 VRU #: 001881945 2/11/10 AP T /S: 02/10/2010 02:09 PM NTART B125 01 2/12/10 KS R *BLDG MONOLITHIC SLAB VRU #: 001882133 2/12/10 AP T /S: 02/12/2010 02:48 PM NTART A814 01 2/15/10 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 001882943 2/17/10 AP T /S: 02/12/2010 12:39 PM NTART /s40 HIGHGROVE DR LOT 89 SPRING LAKE 28390 T /S: 02/17/2010 03:35 PM TWARD R425 01 3/03/10 JH FOUR TRADE ROUGH IN VRU #:001889849 3/03/10 DA 1) Missing fire caulk throughout house on wires O top plates. 2)3' head of water on drain line test no water in pipe. 3)Remove treated 2x4 @ master bath shower. 4)replace 2x6 header for 2x8 in upstairs spare bathroom. 5) - R425 02 3/04/10 JH FOUR TRADE ROUGH IN VRU #: 001890169 3/04/10 DA 3' head of water on drain linesLL I129 01 3/08/10 VC R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891407 3/08/10 CA T /S: 03/05/2010 11:34 AM DJOHNSON T /S: 03/08/2010 08:15 AM VBROWN ANDREW CALLED AND CAN AND ROLLED OVER FOR TUES. R425 03 3/08/10 VC FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 001891415 3/08/10 CA T /S: 03/05/2010 11:35 AM DJOHNSON T /S: 03/08/2010 08:16 AM VBROWN ANDREW CALLED CAN ROLLOVER FOR TUES R425 04 3/09/10 JH FOUR TRADE ROUGH IN VRU #: 001892199 3/09/10 CA house over 2500 square feet I129 02 3/09/10 JH R *INSULATION INSPECTION TIME: 17:00 VRU #: 001891746 3/09/10 AP T /S: 03/08/2010 08:16 AM VBROWN R427 01 3/09/10 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU #: 001891761 3/09/10 AP T /S: 03/08/2010 08:17 AM VBROWN M305 01 3/17/10 JH R *PLUMB SEWER CONNECTION VRU #: 001895804 3/17/10 AP CONTINUED ONTO NEXT PAGE PREPARED 4/06/10, 13:58:26 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 4/07/10 ADDRESS , : 540 HIGHGROVE DR SUBDIV: HIGHGROVE @ANDERSON CRK PH3 30L CONTRACTOR i SAVVY HOMES, LLC PHONE : (919) 787 -5158 OWNER . . : STAFFORD LAND COMPANY INC PHONE : PARCEL . . : 01 -0504- - -0177- -91- APPL NUMBER: 10- 50023656 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS P307 01 3/17/10 JH R *PLUMB WATER CONNECTION VRU #: 001895812 3/17/10 AP R431 01 4/05/10 JH FOUR TRADE FINAL >2500 VRU #: 001904101 4/05/10 DA No insulation in attic & Missing seal on line @ AHU in attic R431 02 4/07/10 /10 TI FOUR TRADE FINAL >2500 VRU #: 001905728 � COMMENTS AND NOTES 4 10 S i t 4 t t cl i e l 4 ,1/ 4. County of Harnett .43 Building Inspections Department Planning Services f C s t ertificate of Compliance: Occupancy: x I Certificate issued pursuant to the requirements of North Carolina General Statute 153A -363 and Harnett County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Hamett and the North Carolina State Building Codes. For the following: ►y Use Classification: SFD Permit Numbers Name: Savvy Homes Building: 10- 50023656 Electrica1: 50 0 2 3656 ,, (( Address: 540 Highgrove Dr Insulation:10 50023656 �\ Spring Lake NC 28390 Plumbing:10- 50023656 V / Mechanical: 10-50023656 ii MFG Home:, Date: 04 -07 -10 Building Official: Brad Sutton g I :, :\ 4 r',14/07,411 C c;'\ C ;7 rf l7 x; •