Loading...
FM REVIEW .,;-: :7 7. Harnett _Z °.� { 0 U N T Y / M Eminency Sunken Department wisistras KORT t {l.RO {ENA ...,.. re wvschamatt.asg Plan Review, Inspection and Permit Fees Application Number 10- 50024089 $150.00 E Explosive Mat. (90 Days) $ 75.00 ❑ Explosive Mat. (72 Hrs) $ 25.00 ❑ Fireworks Public Display $ 35.00 // Final Inspection $ 35.00 +2.00 per device ❑ Fire Alarm Testing $ 35.00 + 2.00 per nozzle E Fixed Fire Suppression $ 25.00 ❑ Insecticide Fog/Fumigation $ 50.00 C Pipe Test/UST /AGST $ 50.00 ® Plans up to 5000 ft $100.00 ❑ Plans 5001 ft to 10,000 fl $150.00 ❑ Plans 10,001 f1 to 25,000 fl $250.00 ❑ Plans 25,001 ft and over $ 35.00 + 2.00 per Head E Sprinkler Certification Test $ 35.00 [ Standpipe Testing $ 25.00 ❑ Special Assembly $ 25.00 Temporary Kiosks/Displays $ 25.00 E Tents, Canopies, Air Supported $ 50.00 [1] Tank Installation (charge for each tank) $ 50.00 ❑ Tank Removal (charge for each tank) $ 85.00 Total Total device/heads Teddy Joe Mclamb 06/03/10 Code Enforcement Official Date • 503.1.1 Fire Department Access o The fire department access shall extend to within 150 feet of all portions of the facility. o The fire department access road shall be of an unobstructed width of not less than 20 feet and shall have an unobstructed vertical clearance of not less the 13 feet 6 inches. • 505.1 Physical Address o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and/or parking lot. o The numbers used to make up the physical address shall be at least 5 inches in height. • 506.1 Knox Box o Knox Box or Knox switch shall be installed on the building or the fence surrounding the building o Keys to be secured in existing knox box Thank you again for submitting the plans for the Office Lex Space. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. If you have any questions, please do not hesitate to call this office. Again, thank you and we look forward to working with you during the construction period! Sincerely, ; 2 gA T.J. McLamb, CFI Chief Deputy Fire Marshal June 3, 2010 Anthony Blanks P.O. Box 766 Spring Lake, NC 27390 Flex Space 6779 Overhills Rd Spring Lake, NC 28390 Application Number 10- 50024089 Mr. Blanks, Thank you for submitting the plans for Flex Office. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 906.1 Fire Extinguishers o Fire extinguishers shall be placed in approved locations as drawn by the code enforcement official on the approved plans. o The fire extinguishers provided shall have a minimum rating of 2A 20B:C and shall not be installed higher than 5 feet above the finished floor