INSPECTIONS PREPARED 10/07/09, 13:58:31 INSPECTION TICKET PAGE 34 Harnett County INSPECTOR: IVR DATE 10/08/09 ADDRESS . : 88 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 88 JACK HARRIS LANE HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE STRUCTURE: 000 000 43X46 4 BR ATTACHED GARAGE/MONOSLA3 FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSP 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10/08/09 TI ~r R*PLUMB UNDER SLAB VRU 001833047 CIOMMEI4TS AND NOTES PREPARED 10/09/09, 14:00:11 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 10/12/09 --------i 4- - ADDRESS 88 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE : (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE : PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 88 JACK HARRIS LANE HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE _ STRUCTURE: 000 000 43X46 4 BR ATTACHED GA^A-GE/MONOSLAB FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10/08/09 JH R*PLUMB UNDER SLAB VRU 001833047 10/08/09 AP - t-pole passed------------ - B101 01 ~110//~12/09 Ip R*BLDG FOOTING / TEMP SVC POLE VRU 001835036 1.SLLl. wft - COMMENTS AND NOTES - - r a Compliance Certificate Project Title: WILLIAMSBURG.- Energy Code: 2003 IECC Location: Lillington, North Carolina Constmction Type: single Family Glazing Area Percentage: 10% Heating Degree Days: 3502 Construction Site: Owner/Agent Designer/Contractor: CHANDLERS RIDGE AMERICAN HOMESMITH AMERICAN HOMESMITH PO BOX 97365 RALEIGH, NC 27624 f , 4`~p~o&aa ✓.ra,~x„b~`~t ! ~T`,y°n vN,~i'~~"~'~~,`i~"~"+~~`~k'. u'~. ~ ~"r'~x .l" Wyr~+.~ky~"rs 2`,y~~,`u' c "r Compliance: Maximum UA: 722 Your UA: 547 ;3 Y" K.t~ ~Y ~ td r der £ C~~'"e ~ f =?3:::345_:4..'..-c`ss_..-..._"~~~~a..,.-.x~~.~.5.~,"=.~Fx.'a.':.N .~:E St ~ .e a?•..~'~`i :.r <fr ~-!~r.~..* Ceiling 1: Flat Ceiling or Scissor Truss 1341 38.0 30.0 21 Wall 1: Wood Frame, 16" o.c. 216 13.0 11.0 9 Window 1: Vinyl Frame:Double Pane with Low-E 17 0,480 8 Window 2: Vinyl Frame:Double, Pane with Low-E 17 0.480 8 Wall 2: Wood Frame, 16" o.c. 171 13.0 11.0 7 Window 3: Vinyl Frame:Double Pare with Low-E 17 0.480 8 Door 1: Glass 12 0.480 6 Wall 3: Wood Frame, 16" o.c. 378 13.0 11.0 19 Window 4: Vinyl Frame:Double Pane with Low-E 7 0.480 3 Wall 4: Wood Frame, 16" o.c. 117 13.0 11.0 4 Window 5: Vinyl Frame:Double Pane with Low-E 34 0.480 16 Wall 5: Wood Frame, 16" o.c. 90 13.0 11.0 4 Door 2: Glass 18 0.480 9 Wall 6: Wood Frame, 16" o.c. 189 13.0 11.0 10 Wall 7: Wood Frame, 16" o.c. 198 13.0 11.0 9 Door 3: Solid 18 0.300 5 Wall 8: Wood Frame, 16" o.c. 189 13.0 11.0 8 Window 6: Vinyl Frame:Double Pane with Low-E 16 0.480 8 Window 7: Vinyl Frame:Double Pane with Low-E 17 0.480 8 Wall 9: Wood Frame, 16" o.c. 126 13.0 11.0 6 Wall 10: Wood Frame, 16" o.c. 99 13.0 11.0 4 Window 8: Vinyl Frame:Double Pane with Low-E 30 0.480 14 Wall 11: Wood Frame, 16" o.c. 171 13.0 11.0 7 Window 9: Vinyl Frame:Double Pane with Low-E 15 0.480 7 Window 10: Vinyl Frame:Double Pane with Low-E 15 0.480 7 Wall 12: Wood Frame, 16"o.c 135 13.0 11.0 7 Wall 13: Wood Frame, 16" o.c. 189 13.0 11.0 10 Wall 14: Wood Frame, 16" o.c. 117 13.0 11.0 4 Window 11: Vinyl Frame:Double, Pare with Low-E 30 0.480 14 Wall 15: Wood Frame, 16" o.c. 81 13.0 11.0 3 Window 12: Vinyl Frame:Double Pane with Low-E 15 0.480 7 Wall 16: Wood Frame, 16" o.c. 198 13.0 11.0 9 Window 13: Vinyl Frame:Double Pane with Low-E 15 0.480 7 Wall 17: Wood Frame, 16" o.c. 108 13.0 11.0 5 Project Title: WILLIAMSBURG Report date: 09/14109 Data filename: C:1Users%TRAVISMD ments%AHS%WILLg1MSBURG.mk Page 1 of 2 Window 14: Vinyl Frame:Double Pane with Low-E 15 0.480 7 Wall 18: Wood Frame, 16" o.c. 54 13.0 11.0 3 Wall 19: Wood Frame, 16' o.c. 126 13.0 11.0 6 Window 15: Vinyl Frame:Double Pane with Low-E 15 0.480 7 Floor 1: Slab-On-Grade:Unheated .233 0.0 243 Insulation depth: 0.0' Heat Pump 1: Air Source 7.7 HSPF, 13 SEER Heat Pump 2: Air Source 7.7 HSPF, 13 SEER Canpliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the pemdt application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.3.0 and to comply with the mandatory requirements listed in t1 R eck Inspection Checklist. Tres vflv3 P(v 1 o 0 N ome- T- Signatu a Date Project Title: WILLIAMSBURG Report date: 09114109 Data filename: C:IUmmre TRAVIS\DocumentslAHSIWILLIAMSBURG.mk Page 2 of 2 PREPARED 11/24/09, 14:00:31 INSPECTION TICKET PAGE 32 Harnett. Courty INSPECTOR: IVR DATE 11/25/09 - - - - ADDRESS- . : 88 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 88 JACK HARRIS LANE. HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE STRUCTURE: 000 000 43X46 4 BR ATTACHED GARAGE/MONOSLAB FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10/08/09 JH R*PLUMB UNDER SLAB VRU 001833047 10/08/09 AP t-pole passed B101 01 10/12/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001835036 10/12/09 AP R425 01 11/25/09 TI ~/~/~~-~~F'OUR TRADE ROUGH IN TIME: 17:00 VRU 001854194 WT/S: 11/24/2009 08:07 AM NTART COMMENTS AND NOTES - - -:3s;u„.,.-.v. v., o...~ ,.v-..,. a.vw,e•..r.....xura: ;r,..~.-- >w+~.,v..«c. M_ , DO NOT REMOVE! Harnett County Inspection Department 102 East Front Street • P.O. Box 65 Lillington, NC 27546 Phone: (910) 893-7527 • Fax: (910) 893-2793 ~q Job Name: r? 8 --TRc k C ✓ , 5 L v Date: Address: Lot No.: Permit No.: 22 9O 9 (Check Box for Violation) ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Footing Foundation Bldg. Elec. Plumb. Mech. Insul. Floor Fram. ❑ ❑ ❑ ❑ ❑ ❑ ❑ Floor MFG. Modular Damp/Water Structural Wall Other Slab Home Proof. Sheath. Violations Found: She-c /`aa4 ~~d Flc,pr /5 ovLA c o o is IAA , V- 14-) 5 - ~Yl4 t.r, o-F 6 llr ~n,~s ,nod N c, lr~~ Code Enforcement Official / 777 DaW Signature ~&JI w h~ It is unlawful for any sub contractor, general contractor, or owner to cover or cause to be covered any part of the work with flooring, sheetrock, earth or other material until the proper inspector had ample time to approve the installation. WHITE COPY - CONTRACTOR/OWNER • YELLOW COPY INSPECTORS PREPARED 12/03/09, 13:58:47 INSPECTION TICKET PAGE 17 Harnett County INSPECTOR: IVR DATE 12/04/09 - - ' ADDRESS 88 JACK HARRIS IN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 88 JACK HARRIS LANE HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE STRUCTURE: 000 000 43X46 4 BR ATTACHED GARAGE/MONOSLAB FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10/08/09 JH R*PLUMB UNDER SLAB VRU 001833047 10/08/09 AP t-pole passed B101 01 10/12/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001835036 10/12/09 AP R425 01 11/25/09 FOUR TRADE ROUGH IN TIME: 17:00 VRU 001854194 11/25/09 DA T/S: 11/24/2009 08:07 AM NTART T/S: 11/25/2009 01:1B PM MREARIC provise accurate truss specs <20-shed roof rafters are over notched at 3rd floor -boots missing tub cannot rest on untreated wood -stair winders must be 4" minimum 6. some truss straps are not nailed R225 01 112~/0t4/0p9~ TI WO TRADE ROUGH IN VRU 001857422 COMMENTS AND NOTES J.S.THOMPSON 0 ENGINEERING, INC structural and geotechnical r~ custom residential design November 30, 2009 Travis Webb American Homesmith LLC PO Box 97365 i Raleigh, NC 27624 Dear Mr. Webb, I The "Williamsburg" plan being constructed on lot 6 Chandler's Ridge subdivision in Harnett County, North Carolina was reviewed along with the pictures and measurements provided to address the over-notched 2 x 8 rafters above the attic dormer. Analysis revealed the 2 x 8 rafters that were trimmed down to a 5" rafter stand height, will provide the required support for all applied loads. No modification is required. Please call me if you have any questions. Sincerely, J.S. Thompson Engineering, Inc. N.C. License No. C-1733 Jeffrey B. Whitson, P.E. SEAL a `rt1 03375~4Q. F'PQIN~` r /300 9 , 60B Wade Avenue i ' Raleigh, NC 27605 (919) 789-9919 oFFicE (919)789-9921 FAX J.S.THOMPSON ENGINEERING, INC structural and geotechnical t i'd custom residential design oil J Y October 16, 2009 Travis Webb American Homesmith LLC. PO Box 97365 I Raleigh, NC 27624 1 i Dear Mr. Webb: Per your request, I have reviewed the 2009 edition of the North Carolina Residential Code to address the foundation anchor requirements and possible alternatives for retrofitting additional anchor mechanisms. Analysis revealed that for wind zones consistent with those of Harnett County, %2" anchor bolts are to be installed @ 6'-0" o.c. and within 1'-0" from the end of each plate. When retrofitting anchor bolts to achieve these minimum I / requirements, the contractor may install 'h" threaded rods embedded a minimum of seven inches into a masonry foundation and secured with epoxy, or if the foundation is a poured concrete wall or monoslab foundation, the contractor may install W' x 6" expansion sleeve anchors such as "Red Heads". Please call me if you have any questions. Sincerely, J.S. Thompson Engineering, Inc. N.C. License No~~.//C-1733 Jeffrey B. Whitson, P.E. .SM I / C~ 033754 s 2 606 Wade Avenue Raleigh, NC 27605 (919) 789-9919 OFFICE (919)789-9921 FAx PREPARED 12/07/09, 14:00:27 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 12/08/09 ADDRESS . : 88 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 88 JACK HARRIS LANE HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE STRUCTURE: 000 000 43X46 4 BR ATTACHED GARAGE/MONOSLAB FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10108109 JH R*PLUMB UNDER SLAB VRU 001833047 10/08/09 AP t-pole passed B101 01 10/12/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001835036 10/12/09 AP R425 01 11/25/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001854194 11/25/09 DA T/S: 11/24/2009 08:07 AM NTART T/S: 11/25/2009 01:18 PM MREARIC 1. provise accurate truss specs 2. shed roof rafters are over notched at 3rd floor 3, boots missing 4. tub cannot rest on untreated wood 5. stair winders must be 4" minimum 6. some truss straps are not nailed R225 01 12/04/09 MR TWO TRADE ROUGH IN VRU 001857422 12/04/09 AP T/S: 12/04/2009 12:59 PM MREARIC A814 01 12//08/09 TI ADDRESS CONFIRMATION VRU 001858828 (aq 1129 01 2/08/09 TI _ R*INSULATION INSPECTION VRU 001858943 12/8/0' rJA )IF - - - COMMENTS AND NOTES - I r- 2;REPAT~ED 1/26/10, 14:06:06 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 1/27/10 ADDRESS . : 88 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE : (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE : PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 86 JACK HARRIS LANE HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE STRUCTURE: 000 000 43X46 4 BR ATTACHED GARAGE/MONOSLAB FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10/08/09 JH R*PLUMB UNDER SLAB VRU 001833047 10/08/09 AP t-pole passed------------------ B101 01 10/12/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001835036 10/12/09 AP R425 01 11/25/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001854194 11/25/09 DA T/S: 11/24/2009 08:07 AM NTART T/S: 11/25/2009 01:18 PM MREARIC 1. provise accurate truss specs 2. shed roof rafters are over notched at 3rd floor 3, boots missing 4. tub cannot rest on untreated wood 5. stair winders must be 4" minimum 6. some truss straps are not nailed R225 01 12/04/09 MR TWO TRADE ROUGH IN VRU 001857422 12/04/09 AP T/S: 12/04/2009 12:59 PM MREARIC I129 01 12/06/09 DT R*INSULATION INSPECTION VRU 001858943 12/08/09 AP T/S: 12/08/2009 11:03 AM DETAYLOR A814 02 12/11/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001858555 12/09/09 AP x/88 jack harris In lot 6------------ spring lake 28390 T/S: 12/09/2009 03:54 PM TWARD R429 01 1/25/10 TI FOUR TRADE FINAL VRU 001875448 1/25/10 CA T/S: 01/25/2010 08:10 AM NTART R429 02 1/27/10 TI FOUR TRADE FINAL VRU 001876312 x-27 r0 L~ln c7jy.! COMMENTS AND NOTES - i \ Violation Notice Do Not Remove Harnett County Inspection Department Jimmy Hall (910)984-4768 Permit #09-50022909 Date: 1/27/10 1) Dishwasher wire needs to be in a box & with wire nuts. 2) Missing light outside of back door. 3) Need flinches from grade to osb sheathing around outside of house. PREPARED 2/09/10,.13:58:02 INSPECTION TICKET PAGE 15 uaauiv County ' , " INSPECTOR: IVR DATE 2/10/10 - - - - - ADDRESS . : 88 JACK HARRIS LN SUBDIV: CHANDLERS RIDGE 21LOTS CONTRACTOR AMERICAN HOMESMITH LLC PHONE (919) 422-4128 OWNER AMERICAN HOMESMITH LLC #6 PHONE PARCEL 01-0514- - -0002- -06- APPL NUMBER: 09-50022909 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/23/2009 04:16 PM DJOHNSON CHANDLERS RIDGE LOT 6 88 JACK HARRIS LANE HWY 210 S TURN RIGHT ONTO OVERHILLS RD TURN RIGHT IN CHANDLERS RIDGE STRUCTURE: 000 000 43X46 4 BR ATTACHED GARAGE/MONOSLAB FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 10/08/09 JH R*PLUMB UNDER SLAB VRU 001833047 10/08/09 AP t-pole passed------------------ B101 01 10/12/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001835036 10/12/09 AP R425 01 11/25/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001854194 11/25/09 DA T/S: 11/24/2009 08:07 AM NTART T/S: 11/25/2009 01:18 PM MREARIC 1. provise accurate truss specs 2. shed roof rafters are over notched at 3rd floor 3, boots missing 4. tub cannot rest on untreated wood 5. stair winders must be 4" minimum 6. some truss straps are not nailed R225 01 12/04/09 MR TWO TRADE ROUGH IN VRU 001857422 12/04/09 AP T/S: 12/04/2009 12:59 PM MREARIC I129 01 12/08/09 DT R*INSULATION INSPECTION VRU 001858943 12/08/09 AP T/S: 12/08/2009 11:03 AM DETAYLOR A814 02 12/11/09 TW V~ADDRESS CONFIRMATION TIME: 17:00 VRU 001858555 12/09/09 AP 88 jack harris In lot 6--------------------- spring lake 28390 T/S: 12/09/2009 03:54 PM TWARD R429 01 1/25/10 TI FOUR TRADE FINAL VRU 001875448 1/25/10 CA T/S: 01/25/2010 08:10 AM NTART R429 02 1/27/10 FOUR TRADE FINAL VRU 001876312 1/27/10 DP 1)Dishwasher wire needs to be in a box & with wire nuts. 2)Missing light outside of back door. 3)Need 8 inches from grade to osd sheathing around outside of house. T/S: 02/09/2010 08:05 AM NTART R431 01 1/29/10 TI FOUR TRADE FINAL >2500 VRU 001877604 1/28/10 CA R431 02 2/10/10 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001880764 Zft'O AP 1) (J T/S: 02/09/2010 08:09 AM NTART COMMENTS AND NOTES 7 T, 1!7, ~vfiw' 61, ~ASJ 6- ~woaol COUNTY.OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code "and the Hamett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Use Classification:. F e.S Conditional Use Peril No.: . Type of Construction: Building Permit No.: ca 6,6\ Owner ofBuilding::"Amv .f cc n pop~eSm Electrical Permit No.: Building Address: 1919 ljA, L, Nor r ;S fir, Insulation Permit No.:. N Zoning Distnck S ~r , L a kc., A C 1$35 0 Plumbing Permit No.. G Zoning Permit No : Mech. Permit No.: Date2110)1D ' Envir. C.O. No.: Buildm (cal Zoning Official j _