INSPECTIONS
PREPARED 9/22/09, 14:17:01 INSPECTION TICKET PAGE 21
Harnett County INSPECTOR: IVR DATE 9/23/09
- -
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECX,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 9/23/09 'fI_ R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
a`7
- - - COMMENTS AND NOTES
PREPARED 9/30/09, 13:59:57 INSPECTION TICKET PAGE 25
Harnett County INSPECTOR: IVR DATE 10/01/09
- - - - -
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5 -
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -
- - -
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
.
B103 01 10/01/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001829613
zn= CO ENTS AND NOTES
PREPARED 10/12/09, 13:59:14 INSPECTION TICKET PAGE 27
Harnett County INSPECTOR: IVR DATE 10/13/09
- - - - - -
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 213ATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
-101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10/01/09 AP t-pole
passed
A814 01 10/02/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 11(3 13/09 TI R*PLUMB UNDER SLAB VRU 001835303
1
1/0` H$ )
- - COMMENTS AND NOTES - -
PREPARED 10/16/09, 14:09:48 INSPECTION TICKET PAGE 16
Harnett County INSPECTOR: IVR DATE 10/19/09
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECX,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10/01/09 AP t-pole
passed------------
A814 01 10/02/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 10/13/09 DT R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
B111 01 10/15/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA
B111 02 10/19/09 TT M R*BLDG SLAB INSP VRU 001837935
COMMENTS AND NOTES
PREPARED 11/09/09, 13:59:31 INSPECTION TICKET PAGE 17
Harnett County INSPECTOR: IVR DATE 11/10/09
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECR,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10/01/09 AP t-pole
passed------------
A814 01 10/02/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 10/13/09 DT R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
B111 01 10/15/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA
13111 02 10/19/09 MR R*BLDG SLAB INSP VRU 001837935
10/19/09 AE damp proofing required vby open floorT/S: 10/19/2009 11:07
AM MREARIC
R425 01 11/10/09 ~I FOUR TRADE ROUGH IN VRU 001846594
(l-lb ~I)lM'
COMMENTS AND NOTES -
PREPARED 11/12/09, 14:33:18 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 11/12/09
- -
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE : (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE :
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSP 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001629613
10/01/09 AP t-pole
passed------------
A814 01 10/02/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 10/13/09 DT R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
B111 01 10/15/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA
B111 02 10/19/09 MR R*BLDG SLAB INSP VRU 001837935
10/19/09 AE damp proofing required vby open floorT/S: 10/19/2009 11:07
AM MREARIC -
R425 O1 11/10/09 KS FOUR TRADE ROUGH IN VRU 001848594
11/10/09 DA 1. Insulation baffles shall be installed for rough-in
2. Plan calls for ladder framing between stair trusses 16
inches on center.
3. Plan calls for lvl across back door--not there
4. Front bedroom wall engineer called for balloon framing
12 inch on center.
Do not insulate Ok to side
T/S: 11/10/2009 01:43 PM KSLATTUM
R425 02 11/_ 12/09 TI FOUR TRADE ROUGH IN VRU 001849557
Z
COMMENTS AND NOTES - -
PREPARED 11/13/09, 14:01:08 INSPECTION TICKET PAGE 4
Harnett County INSPECTOR: IVR DATE 11/16/09
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - - - -
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10/01/09 AP t-pole
passed-
A814 01 10/02/09 TW `ADDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546 ,
T/S: 10/02/2009. 11:17 AM TWARD -
P309 01 10/13/09 DT., R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
B111 01 10/15/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA
8111 02 10/19/09 MR R*BLDG SLAB INSP VRU 001837935
10/19/09 AE damp proofing required vby open floorT/S: 10/19/2009 11:07
AM MREARIC
R425 01 11/10/09 FQkJJR TRADE ROUGH IN VRU 001848594
11/10/09 DA -'1-: Insulation baffles shall be installed for rough-in
1-; Plan calls for ladder framing between stair trusses 16
incSs on center.
Plan calls for lvl across back door--not there
4 Front bedroom wall engineer called for balloon framing
-inch on center.
Do not insulate Ok to side
T/S: 11/10/2009 01:43 PM KSLATTUM
R425 02 11/12/09 TI FOUR TRADE ROUGH IN VRU 001849557
1129 01 11/16/09 TI R*INSULATION INSPECTION VRU 001850223
- - ----------=-L---- COMMENTS AND NOTES -
NG INS 1-t,6%
(,vAfP~' 'J~ 1~S d~vf'SIt~( yl/c~f
f} cctQg
t'otC' s n
PFU ~l
s JnOW tD
PREPARED 11/16/09, 13:59:53 INSPECTION TICKET PAGE 23
Harnett County INSPECTOR: IVR DATE 11/17/09
- - -
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
-
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 SH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10101109 AP t-pole
passed------------
A814 01 10/02/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 10/13/09 DT R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
B111 01 10/15/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA
B111 02 10/19/09 MR R*BLDG SLAB INSP VRU 001837935
10/19/09 AE damp proofing required vby open floorT/S: 10/19/2009 11:07
AM MREARIC -
R425 01 11/10/09 FOUR TRADE ROUGH IN VRU 001848594
11/10/09 DA 1. Insulation baffles shall be installed for rough-in
2. Plan calls for ladder framing between stair trusses 16
inches on center.
3. Plan calls for lvl across back door--not there
4. Front bedroom wall engineer called for balloon framing
12 inch on center.
Do not insulate Ok to side
T/S: 11/10/2009 01:43 PM KSLATTUM
R425 02 11/12/09 TI FOUR TRADE ROUGH IN VRU 001849557
IZ a5
1129 01 11116109 MR R*INSULATION INSPECTION VRU 001850223
11116109 DA T/S: 11/16/2009 11:26 AM MREARIC
insulation is not done behind tubs and showers
water pipes are on outside of envelope
no visible access to attic areas
1129 02 1''1r/r1~7r/00q99 T~Ip R*INSULATION INSPECTION VRU 001851099
-ft
- COMMENTS AND NOTES -
PREPARED 3/08/10, 13:58:54 INSPECTION TICKET PAGE 12
Harnett County INSPECTOR: IVR DATE 3/09/10
- -
ADDRESS : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR{: CAV~INESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION -
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10/01/09 AP t-pole
passed-
A814 01 10/02/09 TW DRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 176
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 10/13/09 DT R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
B111 01 10/15/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA
B111 02 10/19/09 MR R*BLDG SLAB INSP VRU 001837935
10/19/09 AE damp proofing required vby open floorT/S: 10/19/2009 11:07
AM MREARIC
R425 01 11/10/09 KS FOUR TRADE ROUGH IN VRU 001848594
11/10/09 DA 1. Insulation baffles shall be installed for rough-in
2. Plan calls for ladder framing between stair trusses 16
inches on center.
3. Plan calls for lvl across back door--not there
4. Front bedroom wall engineer called for balloon framing
12 inch on center.
Do not insulate Ok to side
T/S: 11/10/2009 01:43 PM KSLATTUM
R425 02 11/12/09 DT FOUR TRADE ROUGH IN VRU 001849557
11/18/09 AP
1129 01 11/16/09 MR R*INSULATION INSPECTION VRU 001850223
11/16/09 DA T/S: 11/16/2009 11:26 AM MREARIC
insulation is not done behind tubs and showers
water pipes are on outside of envelope
no visible access to attic areas
1129 02 11/17/09 DT R*INSULATION INSPECTION VRU 001851099
11/17/09 AP
H824 01 1/07/10 BM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001868488
CONTINUED ONTO NEXT PAGE
PREPARED 3/08/10, 13:58:54 INSPECTION TICKET PAGE 13
Harnett County INSPECTOR: IVR DATE 3/09/10
- - - - -
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR.: CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER CAVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
1/07/10 DA PER BRYAN MCSWAIN NEEDS TANK, PUMP, ALARM, D-BOX AND
WATERLINE CHECKED BEFORE FINAL CAN BE ISSUED. T/S:
01/07/2010 09:46 AM SSTEWART
/T/S: 01/07/2010 09:48 AM SSTEWART
H824 02 1/19/10 BM V ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001873728
1/19/10 AP T/S: 01/20/2010 11:01 AM SSTEWART
T/S: 01/20/2010 11:02 AM SSTEWART
R429 01 3/09/(100 TI FOUR TRADE FINAL VRU 001892367
COMMENTS AND NOTES -
PREPARED 3/10/10, 13:58:58 INSPECTION TICKET PAGE 12
Harriett County INSPECTOR: IVR DATE 3/11/10
- -
ADDRESS . : 221. KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTQR":•CAVYNESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER aVINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : WOODSHIRE SUB DIV #178, KIMBROUGH
DRIVE. 27W, LEFT ON NURSERY RD, ELFT
ON WOOD POINT DR, RIGHT KIMBROUGH
DRIVE.
T/S: 07/13/2009 09:51 AM VBROWN
STRUCTURE: 000 000 65X50 4BDR 2BATH SFD WITH GAR,DECK,SLAB
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
B101 01 9/23/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001826206
9/23/09 AP
B103 01 10/01/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001829613
10/01/09 AP t-pole
passed------------
A814 01 10/02/09 TW 'IDDRESS CONFIRMATION TIME: 17:00 VRU 001828473
10/02/09 AP 221 kimbrough dr lot 178
lillington, nc 27546
T/S: 10/02/2009 11:17 AM TWARD
P309 01 10/13/09 DT R*PLUMB UNDER SLAB VRU 001835303
10/13/09 AP
Bill 01 10/151/09 DT R*BLDG SLAB INSP VRU 001836712
10/15/09 CA '
Bill 02 10/19/09 MR R*BLDG SLAB INSP VRU 001837935
10/19/09 AE damp proofing required vby open floorT/S: 10/19/2009 11:07
AM MREARIC -
R425 01 11/10/09 KS FOUR TRADE ROUGH IN VRU 001848594
11/10/09 DA 1. Insulation baffles shall be installed for rough-in
2. Plan calls for ladder framing between stair trusses 16
inches on center.
3. Plan calls for lvl across back door--not there
4. Front bedroom wall engineer called for balloon framing
12 inch on center.
Do not insulate Ok to side
T/S: 11/10/2009 01:43 PM KSLATTUM
R425 02 11/12/09 DT FOUR TRADE ROUGH IN VRU 001849557
11/18/09 AP
1129 01 11/16/09 MR R*INSULATION INSPECTION VRU 001850223
11/16/09 DA T/S: 11/16/2009 11:26 AM MREARIC
insulation is not done behind tubs and showers
water pipes are on outside of envelope
no visible access to attic areas
1129 02 11/17/09 DT R*INSULATION INSPECTION VRU 001851099
11/17/09 AP /
H824 01 1/07/10 BM X ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001868488
CONTINUED ONTO NEXT PAGE -
PREPARED 3/10/10, 13:58:58 INSPECTION TICKET PAGE 13
karilett County INSPECTOR: IVR DATE 3/11/10
ADDRESS . : 221 KIMBROUGH DR SUBDIV: WOODSHIRE PH 5
CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503
OWNER C6VINESS LAND DEVELOPMENT INC PHONE
PARCEL 01-0536-06- -0028- -18-
APPL NUMBER: 09-50022445 CP NEW RESIDENTIAL (SFD)
- - - -
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
1/07/10 DA PER BRYAN MCSWAIN NEEDS TANK, PUMP, ALARM, D-BOX AND
WATERLINE CHECKED BEFORE FINAL CAN BE ISSUED. T/S:
01/07/2010 09:46 AM SSTEWART
T/S: 01/07/2010 09:48 AM SSTEWART
H824 02 1/19/10 BM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001873728
1/19/10 AP T/S: 01/20/2010 11:01 AM SSTEWART
T/S: 01/20/2010 11:02 AM SSTEWART
R429 01 3/09/10 FOUR TRADE FINAL VRU 001892367
3/09/10 DA 1. No smoke detector outside of upstairs bedroom.
2. Exhaust fan for downstairs spare bath not vented to
outside
3. Need 10 inches settled depth for blown insulation. Need
depth guage visible every 300 sq ft.
T/S: 03/09/2010 01:31 PM DETAYLOR----------------------
R429 02 3/11/10 TI FOUR TRADE FINAL VRU 001893339
31nIto -))q-
COMMENTS AND NOTES - -
y -
-
County of'Harnett 1
Building Inspections Department
Planning Services
Cerfiffncate of C6hipllla nce: Occupancy:
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett
County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the
various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following:
Use Classification: Q %'IAC 1 ' c. Permit Numbers ^
Name: t LuvA eye o act Building:
Electrical:
Address: Z f Insulation: I
L'.lkiflj~ IyI N W71-q6; Plumbing: -
Mechanical: Cl ' I
MFG Home:
Date: Building official:
61