Loading...
INSPECTIONS Harnett County INSPECTOR: IVR DATE 10/12/09 _ - - ADDRESS : 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR : PHONE : OWNER : BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL : 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) - - - - - - DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - B101 01 10/12/09 TI RiBLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001835131 (d•f,2 '09 T/S: 10/09/2009 04:29 PM JBROCK - COMMENTS AND NOTES - PREPARED 10/20/09, 14:06:05 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 10/21/09 ADDRESS . : 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR : PHONE : OWNER BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/12/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001835131 10/12/09 AP T/5: 10/09/2009 04:29 PM JBROCK T/S: 10/13/2009 08:15 AM NTART B101 02 10/21/09 R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001839158 T/S: 10/20/2009 09:35 AM NTART T/S: 10/20/2009 09:40 AM NTART - - COMMENTS AND NOTES - - - - PREPARED 10/23/09. 7:56:36 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 10/23/09 ------w------------------------------------------------------------------------------------ ADDRESS 54617RAWLS-CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR PHONE OWNER BAKER WILLIAM & MICHELLE PHONE (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/12/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001835131 10/12/09 AP T/S: 10/09/2009 04:29 PM JBROCK T/S: 10/13/2009 08:15 AM NTART B101 02 10/21/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001839158 10/21/09 AP T/S: 10/20/2009 09:35 AM NTART T/S: 10/20/2009 09:40 AM NTART ok to pour repair2009 09:42 AM BSUTTON A814 01 10/23/09 TI ADDRESS CONFIRMATION VRU 001840867 B103 01 10123Z09 R*BLDG FOUND & TEMP SVC POLE VRU 001840875 4D-Z- COMMENTS AND NOTES - PREPARED 10/26/09, 14:00:13 INSPECTION TICKET PAGE 23 Harnett County INSPECTOR: IVR DATE 10/27/09 - - ADDRESS . : 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR : PHONE : OWNER BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 10/12/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001835131 10/12/09 AP T/S: 10/09/2009 04:29 PM JBROCK T/S: 10/13/2009 08:15 AM NTART B101 02 10/21/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001839158 10/21/09 AP T/S: 10/20/2009 09:35 AM NTART T/S: 10/20/2009 09:40 AM NTART ok to pour repair2009 09:42 AM BSUTTON A614 01 10/23/09 TI ADDRESS CONFIRMATION VRU 001840867 B103 01 10/23/09 BS R*BLDG FOUND & TEMP SVC POLE VRU 001840875 10/23/09 AE Sweep footing clean, apply damproofing from footing up to final grade line, leave exterior open. Will check damproofing at open floor inspection. B105 01 10/27/09 TI _ R*OPEN FLOOR VRU 001842475 0~zo-7 N COMMENTS AND NOTES - PREPARED 11/23/.09, 13:59:07 INSPECTION TICKET PAGE 22 Harne!ttz05unty INSPECTOR: IVR DATE 11/24/09 ADDRESS 5461 RAWLS CHURCH RD- SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR PHONE : OWNER BAKER WILLIAM & MICHELLE PHONE : (919) 5522-1047~(~i(fi / y E 0216- -02- APPL NUMBER: 09-50022651 CPNEW RESIDENTIAL (SFD) y~~~ •V 1 r~ / DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R427 01 11/ 4/, 09_ FOUR TRADE ROUGH IN >2500 VRU 001853630 -----------/--,-----.-fV---------------------- COMMENTS AND NOTES Violation Notice ®o Not Remove Harnett County Inspection Department 102 East Front St P.O. Box 65 Liilington, INC 27546 Phone (910) 8934876 Fax (910) 893-2793 App #09-50022651 William and Michelle Baker 5461 Rawls Church Road 1. Support tub in master bathroom underneath with shims or a mortar bed. 2. Tie top plate in master bedroom where cut for rear porch beam. 3. Need a plumbing nail plate in front bedroom side of bath lav drain. 4. Firecaulk all holes top and bottom plates for central vac piping. 5. Need a receptacle for kneewall at floor height for dining room. Peninsula in kitchen is considered wallspace. Must be on dining room circuit. 6. Blocking in upstairs wall for gable brick lintel support is missing. Install angle for brick and flash. 7. Plans require a 2x12 ridge throughout house. Provide engineers letter. 8. Install fireplace and gas lines, test all gas piping.9. Install flashing around fireplace enclosure Code Enforcement Official Signature y'cL~ PREPARED 12/01/09, 13:59:42 INSPECTION TICKET PAGE 14 Harnett County INSPECTOR: IVR DATE 12/02/09 AF RESS 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR : PHONE : OWNER BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R427 01 11/24/09 FOUR TRADE ROUGH IN >2500 VRU 001853630 11/29/09 DA 11 upport tub in master bathroom underneath with shims or a mortar bed. O?/fie top plate in master bedroom where cut for. rear porch beam. Need a plumbing nail plate in front bedroom side of tath lav drain. W. Firecaulk-..4ll holes top and bottom plates for central vac piping.,5, Need a receptacle for kneewall at floor height for dining room. Peninsula in kitchen is considered wallspace. Must be on dining room circuit. ~ Blockin in upstairs wall for gable brick lintel support is missing~Tnstall angle for brick and flash. 7. Plans require a 2x12 ridge throughout house. Provide engineers letter. 8. Ins all fireplace and gas lines, test all gas piping., Install flashing around fire ace enclosureT/S: November 29, 2009 08:45 PM BSUTTO o t tub in master bathroo un ea ms r e 2 e top p mas r room here cut for ea V e n. 3 a i na pla n front be o of b av a' Fi e au a 1 top and m ldt r c i i rec t fbr 1 at or e' h 0 d i 0 Pe l i i cc de re a 1 e s be on d'ni 0 B1 king i ta'r al for g ri1 , i p rt s m sing. I tall e' r br d 1 a s quire 2x12 i e thr hout hous - Prod e g e letter 8. I t 11 fir lace" nd g .es, al gas pipi g.9. I tall fl hing around fireplace enclosure R427 02 ~1~2/~022~V T.I. FOUR TRADE ROUGH IN >2500 VRU 001856726 COMMENTS AND NOTES Howerton Services, LLC 7316 Laketree Drive Raleigh, NC 27615 (919) 270-3460 w November 30, 2009 Subject: Baker Residence Hamett County Framing Inspection Per my review of the above referenced location: On_the.main ridge (2"x 10" with 2"x 4" nailed :to-the bottom),fasten a 2"x 5" block to equally cover the seam°betweennthe 2"x 10" and 2"x V with 3 - 9d nails in each member. Placea block between every>set of rafters and on each side of the ridge beam. `~~~~u4U~p pH s OFts.S31"~j+~~t: SEAL 022966 it ;3Q'c9 BP006U01 Harnett County 12/02/09 Edit Narrative 9:30:41 Application number, type 09 50022651 CP NEW RESIDENTIAL (SFD) Pxroperty address . . . . . . 5961 RAWLS CHURCH RD Type information, press Enter. 1.Firecaulk around osb above fire lace. 2.Install as lines and air test. .Install brick lintel on gable en per plan. OK to insulate. Do not brick gable. Ok to pour footings below fireplace. More... F3=Exit F5=Copy F6=Insert F7=Delete F8=Time stamp F12=Cancel F21=User defaults PREPARED 12/11/09, 14:28:37 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 12/14/09 - - - - - - - ADDRESS . : 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR : PHONE : OWNER BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) - - - - - - - DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE K DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - R427 01 11/24/09 BS FOUR TRADE ROUGH IN >2500 VRU 001853630 11/29/09 DA 1.Support tub in master bathroom underneath with shims or a mortar bed. 2. Tie top plate in master bedroom where cut for rear porch beam. 3. Need a plumbing nail plate in front bedroom side of bath lav drain. 4. Firecaulk all holes top and bottom plates for central vac piping. 5. Need a receptacle for kneewall at floor height for dining room. Peninsula in kitchen is considered wallspace. Must be on dining room circuit. 6. Blocking in upstairs wall for gable brick lintel support is missing. Install angle for brick and flash. 7. Plans require a 2x12 ridge throughout house. Provide engineers letter. 8. Install fireplace and gas lines, test all gas piping.9. Install flashing around fireplace enclosureT/S: November 29, 2009 08:45 PM BSUTTO 1.Support tub in master bathroom underneath with shims or a mortar bed. 2. Tie top plate in master bedroom where cut for rear porch beam. 3. Need a plumbing nail plate in front bedroom side of bath lav drain. 4. Firecaulk all holes top and bottom plates for central vac piping. S. Need a receptacle for kneewall at floor height for dining room. Peninsula in kitchen is considered wallspace. Must be on dining room circuit. 6. Blocking in upstairs wall for gable brick lintel support is missing. Install angle for brick and flash. 7. Plans require a 2x12 ridge throughout house. Provide engineers letter. 8. Install fireplace and gas lines, test all gas piping.9. Install flashing around fireplace enclosure R427 02 12/02/09 FOUR TRADE ROUGH IN >2500 VRU 001856726 12/02/09 DA 1.Firecaulk around osb above fireplace. 2.Install gas lines and air test. 3.Install brick lintel on gable end per plan. OK to insulate. Do not brick gable. Ok to pour footings below fireplace. 1129 01 12/14/09 TI M R*INSULATION INSPECTION VRU 001861122 R427 03 12/14/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001861269 A r Me, T/S: 12/11/2009 02:28 PM NTART - PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS F r fck L- 14f e- L .7 PREPARED 2/26/10, 14:26:40 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR DATE 3/01/10 - - - - ADDRESS . : 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR : PHONE : OWNER : BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL : 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON RAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/12/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001835131 10/12/09 AP T/S: 10/09/2009 04:29 PM JBROCK T/S: 10/13/2009 08:15 AM NTART B101 02 10/21/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001839158 10/21/09 AP T/S: 10/20/2009 09:35 AM NTART T/S: 10/20/2009 09:40 AM NTART ok to pour repair2009 09:42 AM BSUTTON B103 01 10/23/09 BS R*BLDG FOUND & TEMP SVC POLE VRU 001840875 10/23/09 AE Sweep footing clean, apply damproofing from footing up to final grade line, leave exterior open. Will check damproofing at open floor inspection. A814 01 10/23/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001840867 11/04/09 AP 5461 RAWLS CHURCH RD REPLACEMENT FUQUAY VARINA 27526 T/S: 11/04/2009 04:16 PM TWARD T/S: 11/04/2009 04:16 PM TWARD B105 01 10/27/09 DT R*OPEN FLOOR VRU 001842475 10/27/09 AP 1129 01 12/14/09 MR R*INSULATION INSPECTION TIME: 17:00 VRU 001861251 12/14/09 AP T/S: 12/11/2009 02:26 PM NTART T/S: 12/14/2009 01:53 PM MREARIC R431 01 /01/10 T FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001888239 -/-to T/S: 02/26/2010 08:58 AM JBROCK INSPECTION NEEDED AROUND LOAM IF POSSIBLE. ROUGH IN INSPECTION WAS DONE AND AP UNDER THE BUILDING PERMIT THAT WAS ADDED TO THIS JOB. T/S: 02/26/2010 09:02 AM JBROCK COMMENTS AND NOTES - PREPARED 3/08/10, 14:06:59 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 3/09/10 ADDRESS . : 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR,: :f ; PHONE : OWNER BAKER WILLIAM & MICHELLE PHONE : (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) - - - - - - - - DIRECTIONS : T/S: 08/12/2009 02:38 PM JBROCK 401 NORTH TKAE LEFT ON PAWLS CHURCH RD GO 1/4 MILES ON LEFT 5461 RAWLS CHURCH STRUCTURE: 000 000 59X75 3BDR CRAWL W/ GARAGE & DECK/SCREEN FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS TANK WATER SUPPLY . . . . . . . COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R427 01 11/24/09 BS FOUR TRADE ROUGH IN >2500 VRU 001853630 11/29/09 DA 1.Support tub in master bathroom underneath with shims or a mortar bed. 2. Tie top plate in master bedroom where cut for rear porch beam. 3. Need a plumbing nail plate in front bedroom side of bath lav drain. 4. Firecaulk all holes top and bottom plates for central vac piping. 5. Need a receptacle for kneewall at floor height for dining room. Peninsula in kitchen is considered wallspace. Must be on dining room circuit. 6. Blocking in upstairs wall for gable - brick lintel support is missing. Install angle for brick and flash. 7. Plans require a 2x12 ridge throughout house. Provide engineers letter. 8. Install fireplace and gas lines, test all gas piping.9. Install flashing around fireplace enclosureT/S: November 29, 2009 08:45 PM BSUTTO 1.Support tub in master bathroom underneath with shims or a mortar bed. 2. Tie top plate in master bedroom where cut for rear porch beam. 3. Need a plumbing nail plate in front bedroom side of bath lav drain. 4. Firecaulk all holes top and bottom plates for central vac piping. 5. Need a receptacle for kneewall at floor height for dining room. Peninsula in kitchen is considered wallspace. Must be on dining room circuit. 6. Blocking in upstairs wall for gable brick lintel support is missing. Install angle for brick and flash. 7. Plans require a 2x12 ridge throughout house. Provide engineers letter. 8. Install fireplace and gas lines, test all gas piping.9. Install flashing around fireplace enclosure R427 02 12/02/09 BS FOUR TRADE ROUGH IN >2500 VRU 001856726 12/02/09 DA 1.Firecaulk around osb above fireplace. 2.Install gas lines and air test. 3.Install brick lintel on gable end per plan. OK to insulate. Do not brick gable. Ok to pour footings below fireplace. 1129 01 12/14/09 MR R*INSULATION INSPECTION VRU 001861122 12/14/09 AP T/S: 12/14/2009 01:50 PM MREARIC R427 03 12/14/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001861269 12/14/09 AE T/S: 12/11/2009 02:28 PM NTART T/S: 12/14/2009 01:52 PM MREARIC CONTINUED ONTO NEXT PAGE PREPARED 3/08/10, 14:06:59 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 3/09/10 ADDRESS 5461 RAWLS CHURCH RD SUBDIV: ODIE LEE WASHINGTON & FAY D CONTRACTOR IF i PHONE OWNER BAKER WILLIAM & MICHELLE PHONE (919) 552-1047 PARCEL 08-0654- - -0216- -02- APPL NUMBER: 09-50022651 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1. still need the brick lintel over garage R131 01 3/09/10 TI ONE TRADE FINAL TIME: 17:00 VRU 001892488 T/S: 03/08/2010 02:06 PM NTART PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - 13101 01 10/12/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001835131 10/12/09 AP T/S: 10/09/2009 04:29 PM JBROCK T/S: 10/13/2009 08:15 AM NTART B101 02 10/21/09 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001839158 10/21/09 AP T/S: 10/20/2009 09:35 AM NTART T/S: 10/20/2009 09:40 AM NTART ok to pour repair2009 09:42 AM BSUTTON B103 01 10/23/09 BS R*BLDG FOUND & TEMP SVC POLE VRU 001840875 10/23/09 AE Sweep footing clean, apply damproofing from footing up to final grade line, leave exterior open. Will check damproofing at open floor inspection. A814 01 10/23/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001840867 11/04/09 AP J5461 PAWLS CHURCH RD REPLACEMENT---------------------- FUQUAY VARINA 27526 T/S: 11/04/2009 04:16 PM TWARD T/S: 11/04/2009 04:16 PM TWARD B105 01 10/27/09 DT R*OPEN FLOOR VRU 001842475 10/27/09 AP 1129 01 12/14/09 MR R*INSULATION INSPECTION TIME: 17:00 VRU 001861251 12/14/09 AP T/S: 12/11/2009 02:26 PM NTART T/S: 12/14/2009 01:53 PM MREARIC R431 01 3/01/10 FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001888239 3/01/10 DA T/S: 02/26/2010 08:58 AM JBROCK INSPECTION NEEDED AROUND LOAM IF POSSIBLE. ROUGH IN INSPECTION WAS DONE AND AP UNDER THE BUILDING PERMIT THAT WAS ADDED TO THIS JOB. T/S: 02/26/2010 09:02 AM JBROCK 1. Handrail in garage does not meet code. 2. Missing a studor vent on washroom laundry tub. 3. Light in attic for unit service in contact with ductwork. 4. Need doors on access openings under crawl space or plastic under floor spaces. 5. Maximum breaker size allowed for 4/0 SE cable is 150 amp. Max for #2 is 80 amps.6. Nail doubles under deck supporting girder and install a hanger to support girder end. R431 02 3 /0G+9/10 FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001892470 T/S: 03/08/2010 02:06 PM NTART - COMMENTS AND NOTES - A ttt COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: J _ Use Classification: sFn Conditional Use Permit No.: _ Type of Construction: V Building Permit No.: 09-50022651 Owner of Building: wiliiam & Michelle Baker Electrical Permit No.: 09-50022651 Building Address: 5461 Rawls Church Rd Insulation Permit No.; 09-50022651 Zoning District: NA Plumbing Permit No.: 09-50022651 Zoning Permit No.: NA Mech. Permit No.: 09-50022651 M Data; 03-09-10 EnVR. C.O. N0.: NA Brad Sutton NA Building Official Zoning Official