Loading...
INSPECTIONS PREPARED 9/15/09, 14:00:18 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 9/16/09 - - - - ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40X60 313DR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION - TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9/16/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 COMMENTS AND NOTES - - PREPARED 9/28/09, 14:12:11 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 9/29/09 ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9/16/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC B103 01 n9/'2~9/0n9 TI R*BLDG FOUND & TEMP SVC POLE VRU 001828357 ~ Da ^ l COMMENTS AND NOTES PREPARED 10/05/09, 13:59:46 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 10/06/09 - - - - - - - ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB - DIV #180. 27W, LEFT ON DOCS RD, RIGHT - ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRDCTURE: 000 000 40X60 3BDR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9/16/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC B103 01 9/29/09 R*BLDG FOUND & TEMP SVC POLE VRU 001828357 9/29/09 DA T/S: 09/29/2009 12:00 PM MREARIC not ready A814 01 10/01/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001829423 10/02/09 AP 127 jumpmaeter dr lot 180 broadway 27505 T/S: 10/02/2009 10:31 AM TWARD B103 02 10/06/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001831487 g>, r. -g B'-~?. COMMENTS AND NOTES - - PREPARED 10/12/09, 13:59:14 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 10/13/09 - - - - ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40%60 3BDR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 9/16/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC B103 01 9/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001828357 9/29/09 DA T/S: 09/29/2009 12:00 PM MREARIC not ready A814 01 10/01/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001829423 10/02/09 AP 127 jumpmaster dr lot 180 broadway 27505 T/S: 10/02/2009 10:31 AM TWARD B103 02 10106109 MR R*BLDG FOUND & TEMP SVC POLE VRU 001831487 10/06/09 AP T/S: 10/06/2009 12:12 PM MREARIC B105 01 10/13/09 T R*OPEN FLOOR VRU 001835156 COMMENTS AND NOTES PREPARED 11/09/09, 13:59:31 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 11/10/09 ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE (919) 639-2073 OWNER : STANCIL BUILDERS INC PHONE PARCEL : 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40X60 313DR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - -101 01 9/16/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC 9103 01 9/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001828357 9/29/09 DA T/S: 09/29/2009 12:00 PM MREARIC not ready A814 01 10/01/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001829423 10/02/09 AP 127 jumpmaeter dr lot 180 broadway 27505 T/S: 10/02/2009 10:31 AM TWARD B103 02 10/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001831487 10/06/09 AP T/S: 10/06/2009 12:12 PM MREARIC 1105 01 10/13/09 MR R*OPEN FLOOR VRU 001835156 10/13/09 AP T/S: 10/13/2009 12:31 PM MREARIC R425 01 11/10/09 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU 001848415 11•! O-Q T/S: 11/09/2009 12:29 PM NTART - COMMENTS AND NOTES - - - , HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 11-10-09 PERMIT # 09-50021751 ADDRESS: 127 jumpmaster VIOLATIONS: 1. Bonus room not wired 2. Front porch 2 x 10 girders are over spanned per table 502.5(1) and they do not have adequate support on ends or lateral bracing 3. Front porch requires 8" columns per plan for support 4. Have eng advise on front porch roof support and provide letter 5. Plmb and mech ok Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED`11/23/09, 14:11:54 INSPECTION TICKET PAGE 1 Harnett 't',ounty INSPECTOR: IVR DATE 11/24/09 --------l---- - - ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) - - - DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD - REQUESTED INSP DESCRIPTION - TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9116109 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC B103 01 9/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001828357 9/29/09 DA T/S: 09/29/2009 12:00 PM MREARIC not ready A814 01 10/01/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001829423 10/02/09 AP 127 jumpmaster dr lot 180 broadway 27505 T/S: 10/02/2009 10:31 AM TWARD B103 02 10/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001831487 10/06/09 AP T/S: 10/06/2009 12:12 PM MREARIC B105 01 10/13/09 MR R*OPEN FLOOR VRU 001835156 10/13/09 AP T/S: 10/13/2009 12:31 PM MREARIC 1425 01 11/10/09 FOUR TRADE ROUGH IN TIME: 17:00 VRU 001848415 11/10/09 DA T/S: 11/09/2009 12:29 PM NTART - T/S: 11/10/2009 01:20 PM MREARIC 1. bonus room not wired 2. front porch roof girders are over spanned and are not supported per plans. ie:8" columns 3. have engineer advise on porch supports 4. porch supports have no lateral support 1129 01 11/24/09 TI ~(J\R*INSULATION INSPECTION VRU 001854684 -1 4 R425 02 11/24/09 TI OUR TRADE ROUGH IN TIME: 17:00 VRU 001854793 A J!- MPI-T/S: 11/23/2009 02:11 PM NTART COMMENTS AND NOTES - - ~ N., TYNDALL ' ENGINEERING & DESIGN, P.A. . vrv nauao • . vrv vese eV Shipwaeh Urivu • Garner • North Cemlin, vsrv www.lyndallenginnerin9 <om November 18, 2009 Bradley Built Inc. 466 Stancil Rd Angier 27501 Email: twaddell@embargmail.com Reference: Engineering Services Lot 180, Patton's Pointe Harnett County, NC Project No.: 09GAR-FO624 To Whom It May Concern: As requested by the builder, a representative of Tyndall Engineering & Design was onsite to visually observe and analyze the following items: t) Determine structural adequacy of the existing (2) 2x 10 member above the front porch in regards to supporting the anticipated loading conditions. 2) Determine structural adequacy of the existing 4x4 posts located on the front porch in regards to supporting the anticipated loading conditions. The following conclusions and recommendations were presented for the above- mentioned items: 1) Based on our visual observations and analysis, the existing (2) 2x 10 member was noted adequate as constricted to support the anticipated loading conditions. 2) Based on our visual observations and analysis, the existing 4x4 posts were noted adequate as constructed to support the anticipated loading conditions. We appreciate the opportunity to assist you during this phase of the project. Should you need further assistance or require additional information please do not hesitate to contact its. Sincerely, Tyndall Engineering & Design lip- v' ~4- 6 • A Clarence L. Harris Pregt'ic CLH109GAR-F0624 I of 1 ;00 ~''F''wit nnN ~```11J~4~(c5 PREPARED 3/05/10, 14:01:21 INSPECTION TICKET PAGE 8 Harnett County] INSPECTOR: IVR DATE 3/08/10 - " - ADDRESS 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40X60 3BDR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9/16/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC B103 01 9/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001828357 9/29/09 DA T/S: 09/29/2009 12:00 PM MREARIC not ready A814 01 10/01/09 TW ~ ADDRESS CONFIRMATION TIME: 17:00 VRU 001829423 10/02/09 AP 127 jumpmaster dr lot 180 broadway 27505 T/S: 10/02/2009 10:31 AM TWARD B103 02 10/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001831487 10/06/09 AP T/S: 10/06/2009 12:12 PM MREARIC B105 01 10/13/09 MR R*OPEN FLOOR VRU 001835156 10/13/09 AP T/S: 10/13/2009 12:31 PM MREARIC R425 01 11/10/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001848415 11/10/09 DA T/S: 11/09/2009 12:29 PM NTART T/S: 11/10/2009 01:20 PM MREARIC 1. bonus room not wired 2. front porch roof girders are over spanned and are not supported per plans. ie:8" columns 3. have engineer advise on porch supports 4. porch supports have no lateral support 1129 01 11/24/09 MR R*INSULATION INSPECTION VRU 001854684 11/24/09 AP T/S: 11/24/2009 12:59 PM MREARIC R425 02 11/24/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001854793 11/24/09 AP T/S: 11/23/2009 02:11 PM NTART /S: 11/24/2009 01:02 PM MREARIC H824 01 12/22/09 OT .;.,'~EENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001865245 12/22/09 AP T/S: 12/23/2009 11:36 AM SSTEWART T/S: 12/23/2009 11:37 AM SSTEWART R429 01 3/08/10 TI FOUR TRADE FINAL VRU 001891420 3 l a ti 6' I26- D - COMMENTS AND NOTES f, HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 03-08-10 PERMIT # 09-50021751 ADDRESS: 127 jumpmaster VIOLATIONS: 1. Access to ac in attic to be 30" high x 22" wide 2. Provide door or panel to access Harnett County Building Department Mike Rearic cell# (910) 984- 4772 I PREPARED 3/08/10, 13:58:54 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 3/09/10 - - - - ADDRESS . : 127 JUMPMASTER DR SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR BRADLEY BUILT INC PHONE (919) 639-2073 OWNER STANCIL BUILDERS INC PHONE PARCEL 03-9597- - -0225- -59- APPL NUMBER: 09-50021751 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 127 JUMPMASTER DRIVE PATTONS POINT SUB DIV #180. 27W, LEFT ON DOCS RD, RIGHT ON MICRO TOWER RD, SUB DIV ON RIGHT. T/S: 03/17/2009 03:41 PM VBROWN STRUCTURE: 000 000 40X60 313DR 2BATH SFD, DECK, GAR, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW SEPTIC WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9/16/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001822148 9/16/09 AP T/S: 09/16/2009 12:12 PM MREARIC B103 01 9/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001828357 9/29/09 DA T/S: 09/29/2009 12:00 PM MREARIC not ready A814 01 10/01/09 TW ,ADDRESS CONFIRMATION TIME: 17:00 VRU 001829423 10/02/09 AP 127 jumpmaster dr lot 180 broadway 27505 T/S: 10/02/2009 10:31 AM TWARD B103 02 10/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001831487 10/06/09 AP T/S: 10/06/2009 12:12 PM MREARIC B105 01 10/13/09 MR R*OPEN FLOOR VRU 001835156 10/13/09 AP T/S: 10/13/2009 12:31 PM MREARIC R425 01 11/10/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001848415 11/10/09 DA T/S: 11/09/2009 12:29 PM NTART T/S: 11/10/2009 01:20 PM MREARIC 1. bonus room not wired 2. front porch roof girders are over spanned and are not supported per plans. ie:8" columns 3. have engineer advise on porch supports 4. porch supports have no lateral support 1129 01 11/24/09 MR R*INSULATION INSPECTION VRU 001854684 11/24/09 AP T/S: 11/24/2009 12:59 PM MREARIC R425 02 11/24/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001854793 11/24/09 AP T/S: 11/23/2009 02:11 PM NTART T/S: 11/24/2009 01:02 PM MREARIC H824 01 12/22/09 OT ~/ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001865245 12/22/09 AP T/S: 12/23/2009 11:36 AM SSTEWART T/S: 12/23/2009 11:37 AM SSTEWART R429 01 3/08/10 MR FOUR TRADE FINAL VRU 001891420 3/08/10 DP T/S: 03/08/2010 11:36 AM NTART T/S: 03/08/2010 11:36 AM NTART T/S: 03/08/2010 11:57 AM MREARIC provide attic access hole 30" x22" and a dor for the hole R429 02 3/09/10 TI FOUR TRADE FINAL VRU 001892124 42 Ak COMMENTS AND NOTES ` County of Harnett Building Inspections Department Planning Services Certificate of Compliance: x Occupancy: Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett, County Zoning Ordinances. This certifies at the time of issuance, this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes. For the following: Use Classification: Q 3 Permit Numbers L51 ay Name I It Tu.c- . Elecr ical: Q!9-:5-n02-/- Ill Address: Insulation: I 1 127 J"utuol,uas e-r ~0 Plumbing: 11 Mechanical: t MFG Home: Date: 3 ~-(O Building Official: ~ /lGt4~ ~~Pt~ 4.4 31 t'