Loading...
INSPECTIONS PREPARED 12/29/09, 13:58:32 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 12/30/09 - ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE@ANDERSON CRK PH3 30L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND CO INC #94 PHONE PARCEL 01-0504- - -0177- -96- APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTH TO RAY RD SUBD IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE - T/S: 12/10/2009 10:21 AM DJOHNSON T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 5OX57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 12/30/09 9 TI ~,f R*PLUMB UNDER SL VRU 001866235 - - - - CO ENTS AND NOTES - PREO, D 12/31/09, 14:00:09 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 1/04/10 ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE®ANDERSON CRK PH3 30L CONTRACTOR : SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER : STAFFORD LAND CO INC #94 PHONE PARCEL : 01-0504- - -0177- -96- APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTH TO RAY RD SUED IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE T/S: 12/10/2009 10:21 AM DJOHNSON T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 5OX57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - P309 01 12/30/09 JH R*PLUMB UNDER SLAB VRU 001866235 12/30/09 AP t-pole passed A814 01 1/04/10 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001866888 T/S: 12/31/2009 11:34 AM NTART B111 01 1/04/10 TI R*BLDG SLAB INSP TIME: 17:00 VRU 001866896 1-4-16) T/S: 12/31/2009 11:34 AM NTART - COMMENTS AND NOTES - A (MUC Associates lnt: 2725 E. Millbrook Rd Suite 121 • Raleigh, North Carolina 27604 (919) 871-0999 Fax (919)871-0335 Project: 11-44,eev,- 19 -/f C Lof 9 q Project Number: SAS; 3 f/UZ S.oOY.~S' Client: Day/Date: /FDA Location, / / Temp/Weather 2 r) I Lh•~!- Type of Inspection: ( )Soils ( )Concrete ( )Structural Steel ( )Asphalt (5c)Foundation ( )Masonry ( )Other Arrive On-Site Time Travel Time. Depart I - _ I Lab Time Total Time No. Trips_ Total Mileage ' Chargeable Equipment Notes: C /nrY✓ G /V[ oir QS I`•" BPS P~~ ~a GS«/ve G~P n L K sa; It to74 r5f nN PJ /rq PXlA d /r^'N lt/G1 (vin,A e I i ~ _T.11 d'_H tV/ iD E ~A/` aw //•Cf//EV! /S / l ~DIiS IA l~e. ea o OA o t6 (1 !i o 9~4 P. Uf, L /D t r SO s .o✓ 1 L I c n ~O T`//4L !J.a ~r/la~IPi / a / /n b) G4/'"'~r todL/ 1 zV(J >~'t/, S/O ll '>NA/QO/f Sf/U •1M/~ ! a/~d1 N/ Sib/S•!-A. `l 1Ll t1 f / f/ OW/;~o (H CAgO ,•2 F QyL., 4P 'e SEAL Reviewed By Printed Name '7c/b Pl Z //414s This Report is Preliminary until reviewed by the engineering staff.. Field Test Data, Locations, Elevations and Depths are Estimated. , C~J( REScheck Software Version 4.2.2 Compliance Certificate Project Title: Sage Energy Code: 20061ECC Location: Spring Lake, North Carolina Construction Type: Single Family Conditioned Floor Area: 3144 ft2 Glazing Area Percentage: 8% Heating Degree Days: 3169 Climate Zone: 3 Construction Site: Owner/Agent: Designer/Contractor: 460 Higtgrove Or Spring Lake, NC 28390 Permit # 0950023406 Compliance: Passes on LIA Compliance: 13.5% Better Than Cade Maximum UA: 583 Your UA: 591 Maximum SHGC: 0.40 Your SHGC: 0.2e Gross Cavity Cont~ Glazing UA Assembly Area or R-Value R-Value or D. Perimeter U-Factor Ceiling 1: Cathedral Ceiling (no attic) 1062 38.0 0.8 29 Ceiling 2: Flat Ceiling or Scissor Truss 498 38.0 0.6 14 Wall 1: Wood Frame, 16" o.c. 1490 13.0 0.8 98 Window 1: Vinyl Frame:Double Pane with Low-E 230 0.350 81 SHGC: 0.28 Door 1: Glass 18 0.350 6 SHGC: 0.28 Door 2: Solid 42 0.500 21 Wall 2: Wood Frame, 16' o.c. 1508 13.0 0.8 124 Floor 1: Slab-On-Grade:Unheated 190 0.0 198 Insulation depth: 0.0' Floor 2: All-Wood Joistrrruss:Over Unconditioned Space 431 19.0 0.8 20 Heat Pump 1: Air Souroe 7.7 HSPF, 13 SEER Air Conditioner 1: Electric Central Air 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specification, and other calculations bmMed with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in REScheck Im 4.2.2 and to comply with the mandatory requirement filed in th EScheck Inspection Checklist. Name -T a Signature Date Project Title: Sage Report date: 01/04110 Data filename: C:1Documents and Settings\BryanMasktoplRes Check TemplateslRes check template SAGE.rck Page 1 of 1 PREPARED 1/20/10, 14:06:17 INSPECTION TICKET PAGE 37 Harnett County INSPECTOR: IVR DATE 1/21/10 - ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE®ANDERSON CRK PH3 30L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND CO INC #94 PHONE PARCEL 01-0504- - -0177- -96- APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTH TO RAY RD SUED IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE T/S: 12/10/2009 10:21 AM DJOHNSON T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 50%57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - - P309 01 12/30/09 JH R*PLUMB UNDER SLAB VRU 001866235 12/30/09 AP t-pole passed A814 01 1/04/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001866888 1/05/10 AP T/S: 12/31/2009 11:34 AM NTART T/S: 01/05/2010 01:33 PM FBURGESS 460 HIGHGROVE DR SPRING LAKE, NC 28390 LOT 94 Bill 01 1/04/10 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001866896 1/04/10 AP T/S: 12/31/2009 11:34 AM NTART M305 01 1/21/10 TI R*PLUMB SEWER CONNECTION VRU 001873991 0 P307 01 1/21/10 TIR*PLUMB WATER CONNECTION VRU 001874007 I-X`In 4K& - COMMENTS AND NOTES PREPARED 1/21/10, 14:01:55 INSPECTION TICKET PAGE 35 Harnett County INSPECTOR: IVR DATE 1/22/10 - - - ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE®ANDERSON CRK PH3 30L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND CO INC #94 PHONE PARCEL 01-0504- - -0177- -96- APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTH TO RAY RD SUBD IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE T/S: 12/10/2009 10:21 AM DJOHNSON T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 50X57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - P309 01 12/30/09 JH R*PLUMB UNDER SLAB VRU 001866235 12/30/09 AP t-pole passed A814 01 1/04/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001866888 1/05/10 AP T/S: 12/31/2009 11:34 AM NTART T/S: 01/05/2010 01:33 PM FBURGESS 460 HIGHGROVE DR SPRING LAKE, NC 28390 LOT 94 - B111 01 1/04/10 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001866896 1/04/10 AP T/S: 12/31/2009 11:34 AM NTART M305 01 1/21/1q, TAI, R*PLUMB SEWER CONNECTION VRU 001873991 l-lb n P307 01 ~v /21/1 R*PLUMB WATER CONNECTION VRU 001874007 d~~c~l R427 01 1/22/10 FOUR TRADE ROUGH IN >2500 VRU 001874700 - la- /Q - - - COMMENTS AND NOTES - f,. PREPARED 1/25/10, 14:00:11 INSPECTION TICKET PAGE 27 Harnett County INSPECTOR: IVR DATE 1/26/10 - - - - - .ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE@ANDERSON CRK PH3 30L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND CO INC #94 PHONE PARCEL 01-0504- - -0177- -96- APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS : VS: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTHTO RAY RD SUED IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE T/S: 12/10/2009 10:21 AM DJOHNSON T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 50X57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SEE) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - P309 01 12/30/09 JH R*PLUMB UNDER SLAB VRU 001866235 12/30/09 AP t-pole passed A814 01 1/04/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001866888 1/05/10 AP T/S: 12/31/2009 11:34 AM NTART T/S: 01/05/2010 01:33 PM FBURGESS 460 HIGHGROVE DR SPRING LAKE, NC 28390 LOT 94 B111 01 1/04/10 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001866896 1/04/10 AP T/S: 12/31/2009 11:34 AM NTART M305 01 1/21/10 JH R*PLUMB SEWER CONNECTION VRU 001873991 1/21/10 AP - - P307 01 1/21/10 JH R*PLUMB WATER CONNECTION VRU 001874007 1/21/10 AP R427 01 1/22/10 FOUR TRADE ROUGH IN >2500 VRU 001874700 1/22/10 DA 1)Nail all lvls throughout house per plans. A)Add king stud @ triple lvl & strap break in top plate. Fire caulk under tub in garage @ water heater. OrFire caulk water line & wires @ top plate in kitchen@ refrigerater & to right of stove hole & 1 1/2" pipe. ;K Missing 2x6 stud @ front door on side wall. G$)~"issing stud @ shower in master bathroom. Missing nails in hangers in hall @ master bed door & attic access . Missing point load in living room @ double I joist. ,•YHeader sizes do not match plans throughout house.- R427 02 1/25/10 VC FOUR TRADE ROUGH IN >2500 VRU 001875244 1/25/10 CA T/S: 01/25/2010 10:40 AM VBROWN R427 03 1/26/10 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001875715 n!~!~~(/~~ T/S: 01/25/2010 10:41 AM VBROWN COMMENTS AND NOTES PREPARED 1/28/10, 13:59:22 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 1/29/10 - - - - - ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE@ANDERSON CRK PH3 30L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND CO INC #94 PHONE PARCEL 01-0504- - -0177- -96- APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTH TO RAY RD SUBD IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE T/S: 12/10/2009 10:21 AM DJOHNSON T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 50X57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSP 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - P309 01 12/30/09 JH R*PLUMB UNDER SLAB VRU 001866235 12/30/09 AP t-pole passed A814 01 1/04/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001866888 1/05/10 AP T/S: 12/31/2009 11:34 AM NTART T/S: 01/05/2010 01:33 PM FBURGESS 460 HIGHGROVE DR SPRING LAKE, NC 28390 LOT 94 B111 01 1/04/10 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001866896 - 1/04/10 AP T/S: 12/31/2009 11:34 AM NTART M305 01 1/21/10 JH R*PLUMB SEWER CONNECTION VRU 001873991 1/21/10 AP P307 01 1/21/10 JH R*PLUMB WATER CONNECTION VRU 001874007 1/21/10 AP - R427 01 1/22/10 JH FOUR TRADE ROUGH IN >2500 VRU 001874700 1/22/10 DA 1)Nail all lvls throughout house per plans. 2)Add king stud @ triple lvl & strap break in top plate. 3)Fire caulk under tub in garage @ water heater. 4)Fire caulk water line & wires @ top plate in kitchen@ refrigerater & to right of stove hole & 1 1/2" pipe. 5)Missing 2x6 stud @ front door on side wall. 6)Missing stud @ shower in master bathroom. 7)Missing nails in hangers in hall @ master bed door & attic access . 8)Missing point load in living room @ double I joist. 9)Header sizes do not match plans throughout house.- R427 02 1/25/10 VC FOUR TRADE ROUGH IN >2500 VRU 001875244 1/25/10 CA T/S: 01/25/2010 10:40 AM VBROWN R427 03 1/26/10 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001875715 1/26/10 AP T/S: 01/25/2010 10:41 AM VBROWN I129 01 1/29/10 TI R*INSULATION INSPECTION VRU 001878024 /L ,~24-/o - - - COMMENTS AND NOTES PREPAAD 2/23/10, 14:00:42 INSPECTION TICKET PAGE 30 Harnett County INSPECTOR: IVR DATE 2/24/10 ADDRESS 460 HIGHGROVE DR SUBDIV: HIGHGROVE@ANDERSON CRK PH3 30L CONTRACTOR ) SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND CO INC #94 PHONE PARCEL 01-0504- - -0177- -96- APPL NUMBER: .09-50023406 CP NEW RESIDENTIAL (SFD) DIRECTIONS T/S: 12/10/2009 10:15 AM DJOHNSON HIGHGROVE AT ACREEK PHS 3 LOT 94 460 HIGHGROVE DRIVE 210 SOUTH TO RAY RD SUBD IS ON LEFT OF RAY RD TURN LEFT INTO HIGHGROVE DRIVE T/S: 12/10/2009 10:21 AM DJOHNSON `T/S: 12/10/2009 10:34 AM DJOHNSON T/S: 12/10/2009 10:40 AM DJOHNSON T/S: 12/10/2009 10:46 AM DJOHNSON STRUCTURE: 000 000 50X57 4BR SLAB ATT GARAGE, PATIO,PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : COUNTY WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 12/30/09 JH R*PLUMB UNDER SLAB VRU 001866235 12/30/09 AP t-pole passed A814 01 1/04/10 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001866888 1/05/10 AP T/S: 12/31/2009 11:34 AM NTART T/S: 01/05/2010 01:33 PM FBURGESS V460 HIGHGROVE DR SPRING LAKE, NC 28390 LOT 94 Bill 01 1/04/10 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001866896 1/04/10 AP T/S: 12/31/2009 11:34 AM NTART M305 01 1/21/10 JH R*PLUMB SEWER CONNECTION VRU 001873991 1/21/10 AP P307 01 1/21/10 JH R*PLUMB WATER CONNECTION VRU 001874007 1/21/10 AP R427 01 1/22/10 JH FOUR TRADE ROUGH IN >2500 VRU 001874700 1/22/10 DA 1)Nail all lvls throughout house per plans. 2)Add king stud @ triple lvl & strap break in top plate. 3)Fire caulk under tub in garage @ water heater. 4)Fire caulk water line & wires @ top plate in kitchen@ refrigerater & to right of stove hole & 1 1/2" pipe. 5)Missing 2x6 stud @ front door on side wall. 6)Missing stud O shower in master bathroom. 7)Missing nails in hangers in hall W master bed door & attic access . s)Missing point load in living room @ double I joist. 9)Header sizes do not match plans throughout house.- R427 02 1/25/10 VC FOUR TRADE ROUGH IN >2500 VRU 001875244 1/25/10 CA T/S: 01/25/2010 10:40 AM VBROWN R427 03 1/26/10 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001875715 1/26/10 AP T/S: 01/25/2010 10:41 AM VBROWN 1129 01 1/29/10 JH R*INSULATION-INSPECTION VRU 001878024 1/29/10 AP - - - CONTINUED ONTO NEXT PAGE a PREPARED 2/23/10, 14:00:42 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 2/24/10 - - - ADDRESS . : 460 HIGHGROVE DR SUBDIV: HIGHGROVE®ANDERSON CRK PH3 30L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 - OWNER ` :i STAFFORD LAND CO INC #94 PHONE PARCEL : 01-0504- - -0177- -96- .APPL NUMBER: 09-50023406 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R431 01 2/24/10 TI FOUR TRADE FINAL >2500 VRU 001886704 ~-Xi-/V COMMENTS AND NOTES - :~`:`gC4+3.~;,,~, f.xia~r-*.~.w,+F2is~ar~K~~~~'~>~~~,r~xM.+N~f;+~v:x,~,t`•t~'ia~~i:'d'7~"255t~a=`~",,i~'w~wn8nk4if~°.<a'~,a~L,L~r;S,=ii~'ri"yvie;:{`;';f ~ "t(c®R COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the fallowing: Use Classification: + Conditional Use Permit No.:~_ Type of Construction: Building Permit No.: %j Owner of Building: Electrical Permit No.. Building Address: Y Insulation Permit No.: Zoning District: Plumbing Permit No. 1~ s l: Zoning Permit No.: Mech. Permit No.: my J _ Date: Envic C.O. No.: C\ 3 Building Official Zoning Official lop N 0 ",10, Nu 1~~ p~~ ;.bd ! II~~ 3 1p~~~~~~~~ p~ 1 P }~'MN I.}~~.:}i ni r,. ~~b'y/ Ili" `4 Y9